{"title":"8000mm大孔径积分球的设计与特性测量","authors":"Zhao Zhang, Z. Wan, Xian-sheng Li, Hong-xing Liu, Jing-xu Sun, Ze-xun Liu, Ya-min Wang, Jianwei Ren, J. Ren","doi":"10.3807/JOSK.2016.20.4.500","DOIUrl":null,"url":null,"abstract":"Integrating spheres play a central role in the radiometric calibration of remote sensors. With the development of the wide field of view (FOV) remote sensors, aperture diameters of remote sensors are becoming larger and larger. To satisfy the radiometric calibration requirements of full FOV and full aperture, an 8000mm diameter large aperture integrating sphere uniform source with a variable exit port was designed and manufactured. This integrating sphere will be used for pre-launch test and radiometric calibration of remote satellites. In this paper, optical theories were used to design the output spectral radiance. The LightTools software based on ray-tracing simulation method was used to determine the best combination and distribution of inner light sources. A spectral experiment was made to verify the spectral radiance design. To reduce the influence of longtime power-on, a new characteristic measurement method was developed to obtain the radiation characteristic of the integrating sphere, which could greatly improve the measuring efficiency. This method could also be applied to measure other large aperture uniform sources. The obtained results indicate that the spatial uniformity is 98.35%, and the angular uniformity at center position is 98.78%.","PeriodicalId":49986,"journal":{"name":"Journal of the Optical Society of Korea","volume":"20 1","pages":"500-509"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Design and Characteristic Measurement of 8000 mm Large Aperture Integrating Sphere\",\"authors\":\"Zhao Zhang, Z. Wan, Xian-sheng Li, Hong-xing Liu, Jing-xu Sun, Ze-xun Liu, Ya-min Wang, Jianwei Ren, J. Ren\",\"doi\":\"10.3807/JOSK.2016.20.4.500\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Integrating spheres play a central role in the radiometric calibration of remote sensors. With the development of the wide field of view (FOV) remote sensors, aperture diameters of remote sensors are becoming larger and larger. To satisfy the radiometric calibration requirements of full FOV and full aperture, an 8000mm diameter large aperture integrating sphere uniform source with a variable exit port was designed and manufactured. This integrating sphere will be used for pre-launch test and radiometric calibration of remote satellites. In this paper, optical theories were used to design the output spectral radiance. The LightTools software based on ray-tracing simulation method was used to determine the best combination and distribution of inner light sources. A spectral experiment was made to verify the spectral radiance design. To reduce the influence of longtime power-on, a new characteristic measurement method was developed to obtain the radiation characteristic of the integrating sphere, which could greatly improve the measuring efficiency. This method could also be applied to measure other large aperture uniform sources. The obtained results indicate that the spatial uniformity is 98.35%, and the angular uniformity at center position is 98.78%.\",\"PeriodicalId\":49986,\"journal\":{\"name\":\"Journal of the Optical Society of Korea\",\"volume\":\"20 1\",\"pages\":\"500-509\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-08-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Optical Society of Korea\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3807/JOSK.2016.20.4.500\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q\",\"JCRName\":\"Physics and Astronomy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Optical Society of Korea","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3807/JOSK.2016.20.4.500","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 4

摘要

积分球在遥感器的辐射定标中起着核心作用。随着大视场遥感器的发展,遥感器的孔径越来越大。为满足全视场、全孔径的辐射定标要求,设计并制造了一种直径8000mm的变出口大孔径积分球均匀源。这个积分球将用于发射前测试和远程卫星的辐射校准。本文利用光学理论对输出光谱辐射进行了设计。采用基于光线追踪模拟法的LightTools软件确定内部光源的最佳组合和分布。通过光谱实验验证了光谱辐射设计的正确性。为了减少长时间通电对积分球辐射特性的影响,提出了一种新的测量积分球辐射特性的方法,大大提高了测量效率。该方法也可用于其他大口径均匀光源的测量。结果表明:空间均匀度为98.35%,中心位置角均匀度为98.78%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and Characteristic Measurement of 8000 mm Large Aperture Integrating Sphere
Integrating spheres play a central role in the radiometric calibration of remote sensors. With the development of the wide field of view (FOV) remote sensors, aperture diameters of remote sensors are becoming larger and larger. To satisfy the radiometric calibration requirements of full FOV and full aperture, an 8000mm diameter large aperture integrating sphere uniform source with a variable exit port was designed and manufactured. This integrating sphere will be used for pre-launch test and radiometric calibration of remote satellites. In this paper, optical theories were used to design the output spectral radiance. The LightTools software based on ray-tracing simulation method was used to determine the best combination and distribution of inner light sources. A spectral experiment was made to verify the spectral radiance design. To reduce the influence of longtime power-on, a new characteristic measurement method was developed to obtain the radiation characteristic of the integrating sphere, which could greatly improve the measuring efficiency. This method could also be applied to measure other large aperture uniform sources. The obtained results indicate that the spatial uniformity is 98.35%, and the angular uniformity at center position is 98.78%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.70
自引率
0.00%
发文量
0
审稿时长
2.3 months
期刊最新文献
A Numerical Study of Different Types of Collimators for a High-Resolution Preclinical CdTe Pixelated Semiconductor SPECT System Dynamic Modulation Transfer Function Analysis of Images Blurred by Sinusoidal Vibration Methods and Systems for High-temperature Strain Measurement of the Main Steam Pipe of a Boiler of a Power Plant While in Service Simulation for Small Lamellar Grating FTIR Spectrometer for Passive Remote Sensing A Novel Optical High-Availability Seamless Redundancy (OHSR) Design Based on Beam Splitting / Combining Techniques
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1