{"title":"尼日利亚阿南布拉州奥博西及其周边地区南卡砂地下水位地球物理调查","authors":"Nelson Onyebuchi Nwobi, Solomon Ekene Okeke, Chekwube Nnamdi Didi, Augustine Obiora Okpara","doi":"10.4236/jwarp.2022.1410038","DOIUrl":null,"url":null,"abstract":"Geophysical investigation for Groundwater which entails the use of vertical electrical sounding (VES) methods was carried out in parts of the Idemili area of Anambra State, Nigeria. Geologically the study area falls within the Nanka Sand, belonging to the Ameki Group in the Tertiary Niger Delta Basin. The investigation intends amongst others to assess the groundwater potential of the area, find out the existence of possible aquifer(s) within the area, and es-timate the possible depth of a borehole. 15 VES stations were established at the site using Ohmega System Tetrameter and Schlumberger electrode configuration with current electrode spacing (AB/2) of 350 meters. The geologic parameters, such as the number of geo-electric layers, the thickness of the geo-electric units, and their resistivities were interpreted from the VES curves. A qualitative assessment of the curves shows that a model with 5 layers would sufficiently model the field curves. The thickness value ranged from 0.1 to 86 m, the resistivity ranged from 258 to 13,258 Ωm, and the depth ranged between 1.2 and 109 m. Quantitative interpretation of field curves involved inversion with appropriate parameters using Zond Res1D software.","PeriodicalId":56705,"journal":{"name":"水资源与保护(英文)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Geophysical Investigation of Groundwater Potentials of the Nanka Sand in Obosi and Its Environs, Anambra State Nigeria\",\"authors\":\"Nelson Onyebuchi Nwobi, Solomon Ekene Okeke, Chekwube Nnamdi Didi, Augustine Obiora Okpara\",\"doi\":\"10.4236/jwarp.2022.1410038\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Geophysical investigation for Groundwater which entails the use of vertical electrical sounding (VES) methods was carried out in parts of the Idemili area of Anambra State, Nigeria. Geologically the study area falls within the Nanka Sand, belonging to the Ameki Group in the Tertiary Niger Delta Basin. The investigation intends amongst others to assess the groundwater potential of the area, find out the existence of possible aquifer(s) within the area, and es-timate the possible depth of a borehole. 15 VES stations were established at the site using Ohmega System Tetrameter and Schlumberger electrode configuration with current electrode spacing (AB/2) of 350 meters. The geologic parameters, such as the number of geo-electric layers, the thickness of the geo-electric units, and their resistivities were interpreted from the VES curves. A qualitative assessment of the curves shows that a model with 5 layers would sufficiently model the field curves. The thickness value ranged from 0.1 to 86 m, the resistivity ranged from 258 to 13,258 Ωm, and the depth ranged between 1.2 and 109 m. Quantitative interpretation of field curves involved inversion with appropriate parameters using Zond Res1D software.\",\"PeriodicalId\":56705,\"journal\":{\"name\":\"水资源与保护(英文)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"水资源与保护(英文)\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.4236/jwarp.2022.1410038\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"水资源与保护(英文)","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.4236/jwarp.2022.1410038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Geophysical Investigation of Groundwater Potentials of the Nanka Sand in Obosi and Its Environs, Anambra State Nigeria
Geophysical investigation for Groundwater which entails the use of vertical electrical sounding (VES) methods was carried out in parts of the Idemili area of Anambra State, Nigeria. Geologically the study area falls within the Nanka Sand, belonging to the Ameki Group in the Tertiary Niger Delta Basin. The investigation intends amongst others to assess the groundwater potential of the area, find out the existence of possible aquifer(s) within the area, and es-timate the possible depth of a borehole. 15 VES stations were established at the site using Ohmega System Tetrameter and Schlumberger electrode configuration with current electrode spacing (AB/2) of 350 meters. The geologic parameters, such as the number of geo-electric layers, the thickness of the geo-electric units, and their resistivities were interpreted from the VES curves. A qualitative assessment of the curves shows that a model with 5 layers would sufficiently model the field curves. The thickness value ranged from 0.1 to 86 m, the resistivity ranged from 258 to 13,258 Ωm, and the depth ranged between 1.2 and 109 m. Quantitative interpretation of field curves involved inversion with appropriate parameters using Zond Res1D software.