{"title":"两种现代准分子激光器屈光手术中pmmA板表面温度的变化","authors":"Csaba Szekrényesi, Kata Réz, Z. Nagy","doi":"10.5604/14270994.1228144","DOIUrl":null,"url":null,"abstract":"Introduction. the conditions in the operating room can have an influence on the postoperative results of the refractive surgery performed with excimer lasers. Aim. the aim of this study was to examine the relationship of the temperature of pmma plates (polymethylmethacrylate), environmental conditions and the energy load caused by the laser impulses during refractive surgery procedure. Material and methods. wavelight allegretto and Schwind amaris excimer lasers were used for the study. polymethylmethacrylate (pmma) plates with parameters: -10 dpt myopic ablation and 6.5 mm optical zone were used as a target for photoablation during the calibration of excimer lasers. energy load and temperature rise were measured with high accuracy infrared thermometer. Results. logarithmically rising temperature was measured for both lasers. maximal temperature measuredwas 48°c for the allegretto laser and 43°c for the amaris laser. Conclusions. higher energy load with smaller repetition rate causes higher thermal load. thermal load of the pmma plate during the ablation is dependent on the environmental conditions, such as temperature, humidity, air flow, smoke plume evacuation, etc.","PeriodicalId":55698,"journal":{"name":"New Medicine","volume":"20 1","pages":"125-128"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"sUrFACe temperAtUre ChAnGe oF pmmA plAtes in reFrACtiVe sUrGery perFormed With tWo types oF modern eXCimer lAsers\",\"authors\":\"Csaba Szekrényesi, Kata Réz, Z. Nagy\",\"doi\":\"10.5604/14270994.1228144\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction. the conditions in the operating room can have an influence on the postoperative results of the refractive surgery performed with excimer lasers. Aim. the aim of this study was to examine the relationship of the temperature of pmma plates (polymethylmethacrylate), environmental conditions and the energy load caused by the laser impulses during refractive surgery procedure. Material and methods. wavelight allegretto and Schwind amaris excimer lasers were used for the study. polymethylmethacrylate (pmma) plates with parameters: -10 dpt myopic ablation and 6.5 mm optical zone were used as a target for photoablation during the calibration of excimer lasers. energy load and temperature rise were measured with high accuracy infrared thermometer. Results. logarithmically rising temperature was measured for both lasers. maximal temperature measuredwas 48°c for the allegretto laser and 43°c for the amaris laser. Conclusions. higher energy load with smaller repetition rate causes higher thermal load. thermal load of the pmma plate during the ablation is dependent on the environmental conditions, such as temperature, humidity, air flow, smoke plume evacuation, etc.\",\"PeriodicalId\":55698,\"journal\":{\"name\":\"New Medicine\",\"volume\":\"20 1\",\"pages\":\"125-128\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"New Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5604/14270994.1228144\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"New Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5604/14270994.1228144","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
sUrFACe temperAtUre ChAnGe oF pmmA plAtes in reFrACtiVe sUrGery perFormed With tWo types oF modern eXCimer lAsers
Introduction. the conditions in the operating room can have an influence on the postoperative results of the refractive surgery performed with excimer lasers. Aim. the aim of this study was to examine the relationship of the temperature of pmma plates (polymethylmethacrylate), environmental conditions and the energy load caused by the laser impulses during refractive surgery procedure. Material and methods. wavelight allegretto and Schwind amaris excimer lasers were used for the study. polymethylmethacrylate (pmma) plates with parameters: -10 dpt myopic ablation and 6.5 mm optical zone were used as a target for photoablation during the calibration of excimer lasers. energy load and temperature rise were measured with high accuracy infrared thermometer. Results. logarithmically rising temperature was measured for both lasers. maximal temperature measuredwas 48°c for the allegretto laser and 43°c for the amaris laser. Conclusions. higher energy load with smaller repetition rate causes higher thermal load. thermal load of the pmma plate during the ablation is dependent on the environmental conditions, such as temperature, humidity, air flow, smoke plume evacuation, etc.
期刊介绍:
- New Medicine is indexed in Index Copernicus (IC value 6.60) and registered in Embase/Excerpta Medica. - It is published in English and some issues in other languages. - New Medicine covers a broad spectrum of disciplines. - New Medicine is sent to national and medical libraries in several countries all over the world and to some libraries and institutions in Poland. It is also present on medical conferences. - New Medicine is published under the patronage of Polish Society of Health Education.