{"title":"选择性PVC基质辅助电位传感器测定盐酸羟嗪(HDH)","authors":"R. N. Prasad, C. Siddaraju","doi":"10.4152/pea.2022400503","DOIUrl":null,"url":null,"abstract":"A membrane sensor using an ion association complex of hydroxyzine hydrochloride (HDH) with Orange II (ORG-II) dye, in a polyvinyl chloride (PVC) matrix, has been developed and used as a selective electrode for HDH quantification in pharmaceuticals. The sensor is suitable to determine 2.2 × 10 -5 - 1.1 × 10 -3 mol L -1 HDH, in the pH range from 2.5 to 5.21, with the Nernstian slope of 57.41±1.04 mV/decade, under optimum conditions. The regression coefficient (RC) value of 0.999 shows a good correlation between HDH concentration and the potential measured using the proposed sensor. The sensor limit of detection (LOD) was 4.5 × 10 -6 M. A standard-addition procedure was followed to study the effect of various interferents. The results revealed no variations caused by foreign ions or species. The regression equation (RE) and relative standard deviation (RSD) values, from 1.67 to 5, and from 1.86 to 4.81%, respectively, indicated the HDH-ORG sensor acceptable accuracy and precision. The RSD values of ≤5.67 and <5% indicated the sensor acceptable robustness and ruggedness, respectively. It has been successfully used to determine HDH in tablets, and excellent results were obtained.","PeriodicalId":20334,"journal":{"name":"Portugaliae Electrochimica Acta","volume":"30 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Selective PVC Matrix Assisted Potentiometric Sensor for the Determination of Hydroxyzine Hydrochloride (HDH)\",\"authors\":\"R. N. Prasad, C. Siddaraju\",\"doi\":\"10.4152/pea.2022400503\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A membrane sensor using an ion association complex of hydroxyzine hydrochloride (HDH) with Orange II (ORG-II) dye, in a polyvinyl chloride (PVC) matrix, has been developed and used as a selective electrode for HDH quantification in pharmaceuticals. The sensor is suitable to determine 2.2 × 10 -5 - 1.1 × 10 -3 mol L -1 HDH, in the pH range from 2.5 to 5.21, with the Nernstian slope of 57.41±1.04 mV/decade, under optimum conditions. The regression coefficient (RC) value of 0.999 shows a good correlation between HDH concentration and the potential measured using the proposed sensor. The sensor limit of detection (LOD) was 4.5 × 10 -6 M. A standard-addition procedure was followed to study the effect of various interferents. The results revealed no variations caused by foreign ions or species. The regression equation (RE) and relative standard deviation (RSD) values, from 1.67 to 5, and from 1.86 to 4.81%, respectively, indicated the HDH-ORG sensor acceptable accuracy and precision. The RSD values of ≤5.67 and <5% indicated the sensor acceptable robustness and ruggedness, respectively. It has been successfully used to determine HDH in tablets, and excellent results were obtained.\",\"PeriodicalId\":20334,\"journal\":{\"name\":\"Portugaliae Electrochimica Acta\",\"volume\":\"30 1\",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Portugaliae Electrochimica Acta\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4152/pea.2022400503\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Portugaliae Electrochimica Acta","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4152/pea.2022400503","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
A Selective PVC Matrix Assisted Potentiometric Sensor for the Determination of Hydroxyzine Hydrochloride (HDH)
A membrane sensor using an ion association complex of hydroxyzine hydrochloride (HDH) with Orange II (ORG-II) dye, in a polyvinyl chloride (PVC) matrix, has been developed and used as a selective electrode for HDH quantification in pharmaceuticals. The sensor is suitable to determine 2.2 × 10 -5 - 1.1 × 10 -3 mol L -1 HDH, in the pH range from 2.5 to 5.21, with the Nernstian slope of 57.41±1.04 mV/decade, under optimum conditions. The regression coefficient (RC) value of 0.999 shows a good correlation between HDH concentration and the potential measured using the proposed sensor. The sensor limit of detection (LOD) was 4.5 × 10 -6 M. A standard-addition procedure was followed to study the effect of various interferents. The results revealed no variations caused by foreign ions or species. The regression equation (RE) and relative standard deviation (RSD) values, from 1.67 to 5, and from 1.86 to 4.81%, respectively, indicated the HDH-ORG sensor acceptable accuracy and precision. The RSD values of ≤5.67 and <5% indicated the sensor acceptable robustness and ruggedness, respectively. It has been successfully used to determine HDH in tablets, and excellent results were obtained.
期刊介绍:
Portugaliae Electrochimica Acta is a bi-monthly Journal published by the Portuguese Electrochemical Society since 1983. Portugaliae Electrochimica Acta publishes original papers, brief communications, reviews and letters concerned with every aspect of theory and practice of electrochemistry, as well as articles in which topics on history, science policy, education, etc. in the electrochemical field (teaching or research) may be discussed.