{"title":"引水结构对减少山地森林生态系统滑径径流、产沙量、硝酸盐和磷酸盐浓度的有效性","authors":"M. Jourgholami, M. E. Abari, R. Venanzi, F. Tavankar, R. Picchio","doi":"10.5552/crojfe.2022.1563","DOIUrl":null,"url":null,"abstract":"It is well-known that soil and water conservation actions (e.g., installing water diversion structures) are necessary to restore skid trails after logging operations. However, there are some points that have yet to be determined concerning the efficacy of rehabilitation on sediment yield and nutrient export to the aquatic environment. The objectives of this study were to determine the optimal distance among the water diversion structures (WDSs) to suppress runoff, sediment yield, and measure nitrogen and phosphorus concentrations on the skid trails of a mountainous ecosystem. The study was conducted on a total of 18 bounded runoff plots, each with a width of 4 m and a length of 120 m, divided into six treatment compartments done in triplicate. Beech logs were placed at a distance of 5, 10, 20, 30, and 40 meters. An untreated area (U) was set up during the recording period from 18 September 2015 to 17 September 2016. In all the WDS treatments and untreated trails (U), the observed peaks of runoff, sediment yield, as well as nitrate and phosphate concentrations was found to be significantly correlated with the amount of rainfall events. Results show that there was a decrease in surface runoff and runoff coefficient, sediment yield, and nitrate and phosphate concentrations by installing of WDS at different distances. The runoff and runoff coefficients (2.67 mm and 0.101, respectively) were at the lowest level in the WDS20 (WDS at a distance of 20 m). The sediment yield was significantly higher on the U, 13.52 g m-2 followed by WDS40, whereas the lowest values were detected at the WDS10. Significantly higher values of nitrate were found in the U (3.63 mg l-1), while the lowest amounts of nitrate were determined at WDS5 followed by the WDS20 treatment. The highest values of phosphate were found on the U treatment (0.278 mg l-1) followed by the WDS40 treatment, whereas the lowest phosphate values were measured in the WDS20 treated area. Therefore, it can be deduced that the recommended water diversion structure should be placed at a distance of 20 m to mitigate runoff, sediment yield, nitrate and phosphate exports on the skid trails.","PeriodicalId":55204,"journal":{"name":"Croatian Journal of Forest Engineering","volume":"1 1","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effectiveness of Water Diversion Structure to Mitigate Runoff, Sediment Yield, Nitrate and Phosphate Concentrations in Skid Trail of Mountainous Forest Ecosystem\",\"authors\":\"M. Jourgholami, M. E. Abari, R. Venanzi, F. Tavankar, R. Picchio\",\"doi\":\"10.5552/crojfe.2022.1563\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is well-known that soil and water conservation actions (e.g., installing water diversion structures) are necessary to restore skid trails after logging operations. However, there are some points that have yet to be determined concerning the efficacy of rehabilitation on sediment yield and nutrient export to the aquatic environment. The objectives of this study were to determine the optimal distance among the water diversion structures (WDSs) to suppress runoff, sediment yield, and measure nitrogen and phosphorus concentrations on the skid trails of a mountainous ecosystem. The study was conducted on a total of 18 bounded runoff plots, each with a width of 4 m and a length of 120 m, divided into six treatment compartments done in triplicate. Beech logs were placed at a distance of 5, 10, 20, 30, and 40 meters. An untreated area (U) was set up during the recording period from 18 September 2015 to 17 September 2016. In all the WDS treatments and untreated trails (U), the observed peaks of runoff, sediment yield, as well as nitrate and phosphate concentrations was found to be significantly correlated with the amount of rainfall events. Results show that there was a decrease in surface runoff and runoff coefficient, sediment yield, and nitrate and phosphate concentrations by installing of WDS at different distances. The runoff and runoff coefficients (2.67 mm and 0.101, respectively) were at the lowest level in the WDS20 (WDS at a distance of 20 m). The sediment yield was significantly higher on the U, 13.52 g m-2 followed by WDS40, whereas the lowest values were detected at the WDS10. Significantly higher values of nitrate were found in the U (3.63 mg l-1), while the lowest amounts of nitrate were determined at WDS5 followed by the WDS20 treatment. The highest values of phosphate were found on the U treatment (0.278 mg l-1) followed by the WDS40 treatment, whereas the lowest phosphate values were measured in the WDS20 treated area. Therefore, it can be deduced that the recommended water diversion structure should be placed at a distance of 20 m to mitigate runoff, sediment yield, nitrate and phosphate exports on the skid trails.\",\"PeriodicalId\":55204,\"journal\":{\"name\":\"Croatian Journal of Forest Engineering\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Croatian Journal of Forest Engineering\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.5552/crojfe.2022.1563\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"FORESTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Croatian Journal of Forest Engineering","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.5552/crojfe.2022.1563","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"FORESTRY","Score":null,"Total":0}
引用次数: 0

摘要

众所周知,水土保持措施(例如,安装引水结构)对于恢复伐木作业后的滑道是必要的。然而,关于恢复对产沙量和向水生环境输出养分的功效,有一些问题尚未确定。本研究的目的是确定引水结构(WDSs)之间的最佳距离,以抑制径流,产沙量,并测量山区生态系统滑道上的氮和磷浓度。该研究共在18个有界径流地块上进行,每个地块宽度为4 m,长度为120 m,分为6个处理隔间,一式三次。山毛榉原木分别放置在5米、10米、20米、30米和40米的距离上。在2015年9月18日至2016年9月17日的记录期间建立了一个未经处理的区域(U)。在所有WDS处理和未处理路径(U)中,观测到的径流量、产沙量以及硝酸盐和磷酸盐浓度峰值与降雨事件的数量呈显著相关。结果表明,在不同距离设置WDS后,地表径流量、径流系数、产沙量、硝酸盐和磷酸盐浓度均有所降低。径流系数和径流系数在WDS20(距离为20 m)处最低,分别为2.67 mm和0.101,产沙量在U处最高,为13.52 g m-2,其次是WDS40,而在WDS10处最低。U中硝酸盐含量最高(3.63 mg l-1), WDS5处理的硝酸盐含量最低,其次是WDS20处理。磷含量最高的是U处理(0.278 mg l-1),其次是WDS40处理,最低的是WDS20处理。因此,可以推断,推荐的引水结构应放置在距离20 m的地方,以减少滑道上的径流,产沙量,硝酸盐和磷酸盐的出口。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effectiveness of Water Diversion Structure to Mitigate Runoff, Sediment Yield, Nitrate and Phosphate Concentrations in Skid Trail of Mountainous Forest Ecosystem
It is well-known that soil and water conservation actions (e.g., installing water diversion structures) are necessary to restore skid trails after logging operations. However, there are some points that have yet to be determined concerning the efficacy of rehabilitation on sediment yield and nutrient export to the aquatic environment. The objectives of this study were to determine the optimal distance among the water diversion structures (WDSs) to suppress runoff, sediment yield, and measure nitrogen and phosphorus concentrations on the skid trails of a mountainous ecosystem. The study was conducted on a total of 18 bounded runoff plots, each with a width of 4 m and a length of 120 m, divided into six treatment compartments done in triplicate. Beech logs were placed at a distance of 5, 10, 20, 30, and 40 meters. An untreated area (U) was set up during the recording period from 18 September 2015 to 17 September 2016. In all the WDS treatments and untreated trails (U), the observed peaks of runoff, sediment yield, as well as nitrate and phosphate concentrations was found to be significantly correlated with the amount of rainfall events. Results show that there was a decrease in surface runoff and runoff coefficient, sediment yield, and nitrate and phosphate concentrations by installing of WDS at different distances. The runoff and runoff coefficients (2.67 mm and 0.101, respectively) were at the lowest level in the WDS20 (WDS at a distance of 20 m). The sediment yield was significantly higher on the U, 13.52 g m-2 followed by WDS40, whereas the lowest values were detected at the WDS10. Significantly higher values of nitrate were found in the U (3.63 mg l-1), while the lowest amounts of nitrate were determined at WDS5 followed by the WDS20 treatment. The highest values of phosphate were found on the U treatment (0.278 mg l-1) followed by the WDS40 treatment, whereas the lowest phosphate values were measured in the WDS20 treated area. Therefore, it can be deduced that the recommended water diversion structure should be placed at a distance of 20 m to mitigate runoff, sediment yield, nitrate and phosphate exports on the skid trails.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.20
自引率
12.50%
发文量
23
审稿时长
>12 weeks
期刊介绍: Croatian Journal of Forest Engineering (CROJFE) is a refereed journal distributed internationally, publishing original research articles concerning forest engineering, both theoretical and empirical. The journal covers all aspects of forest engineering research, ranging from basic to applied subjects. In addition to research articles, preliminary research notes and subject reviews are published. Journal Subjects and Fields: -Harvesting systems and technologies- Forest biomass and carbon sequestration- Forest road network planning, management and construction- System organization and forest operations- IT technologies and remote sensing- Engineering in urban forestry- Vehicle/machine design and evaluation- Modelling and sustainable management- Eco-efficient technologies in forestry- Ergonomics and work safety
期刊最新文献
Incorporating Simulators into a Training Curriculum for Forestry Equipment Operators Comparing Different Replacement Policies for Logging Machines in Brazil Effects of Boom-Corridor and Selective Thinnings on Harvester Productivity in Dense Small Diameter Pyrenean Oak (Quercus pyrenaica Willd.) Coppices in Spain Soil Characteristics in Oak Lowland Stand Assessment of Tractor Tires Used in Forest Conditions in Terms of Traction Performance and Impact on Ground
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1