一种使用3D相机和自定义龙门架自动采集数字屈曲的系统。

IF 0.9 Q4 REHABILITATION Hand Therapy Pub Date : 2022-09-01 Epub Date: 2022-06-22 DOI:10.1177/17589983221110916
David M Brogan, Aws Anaz, Marjorie Skubic, Christopher J Dy, Jay Bridgeman
{"title":"一种使用3D相机和自定义龙门架自动采集数字屈曲的系统。","authors":"David M Brogan,&nbsp;Aws Anaz,&nbsp;Marjorie Skubic,&nbsp;Christopher J Dy,&nbsp;Jay Bridgeman","doi":"10.1177/17589983221110916","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Automated measurement of digital range of motion (ROM) may improve the accuracy of reporting and increase clinical efficiency. We hypothesize that a 3-D camera on a custom gantry will produce ROM measurements similar to those obtained with a manual goniometer.</p><p><strong>Methods: </strong>A 3-D camera mounted on a custom gantry, was mechanized to rotate 200° around a platform. The video was processed to segment each digit and calculate joint angles in people with no history of any hand conditions or surgery to validate the system. A second-generation prototype was then assessed in people with different hand conditions. Metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joint flexion were measured repeatedly with a goniometer and the automated system. The average difference between manual and automatic measurements was calculated along with intraclass correlation coefficients (ICC).</p><p><strong>Results: </strong>In the initial validation, 1,488 manual and 1,488 automated joint measurements were obtained and the measurement algorithm was refined. In people with hand conditions, 688 manual and 688 automated joint measurements were compared. Average acquisition time was 7 s per hand, with an additional 2-3 s required for data processing. ICC between manual and automated data in the clinical study ranged from 0.65 to 0.85 for the MCP joints, and 0.22 to 0.66 for PIP joints.</p><p><strong>Discussion: </strong>The automated system resulted in rapid data acquisition, with reliability varying by type of joint and location. It has the potential to improve efficiency in the collection of physical exam findings. Further developments of the system are needed to measure thumb and distal phalangeal motions.</p>","PeriodicalId":43971,"journal":{"name":"Hand Therapy","volume":"27 3","pages":"91-99"},"PeriodicalIF":0.9000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10588428/pdf/","citationCount":"0","resultStr":"{\"title\":\"A system for automated acquisition of digital flexion using a 3-D camera and custom gantry.\",\"authors\":\"David M Brogan,&nbsp;Aws Anaz,&nbsp;Marjorie Skubic,&nbsp;Christopher J Dy,&nbsp;Jay Bridgeman\",\"doi\":\"10.1177/17589983221110916\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Automated measurement of digital range of motion (ROM) may improve the accuracy of reporting and increase clinical efficiency. We hypothesize that a 3-D camera on a custom gantry will produce ROM measurements similar to those obtained with a manual goniometer.</p><p><strong>Methods: </strong>A 3-D camera mounted on a custom gantry, was mechanized to rotate 200° around a platform. The video was processed to segment each digit and calculate joint angles in people with no history of any hand conditions or surgery to validate the system. A second-generation prototype was then assessed in people with different hand conditions. Metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joint flexion were measured repeatedly with a goniometer and the automated system. The average difference between manual and automatic measurements was calculated along with intraclass correlation coefficients (ICC).</p><p><strong>Results: </strong>In the initial validation, 1,488 manual and 1,488 automated joint measurements were obtained and the measurement algorithm was refined. In people with hand conditions, 688 manual and 688 automated joint measurements were compared. Average acquisition time was 7 s per hand, with an additional 2-3 s required for data processing. ICC between manual and automated data in the clinical study ranged from 0.65 to 0.85 for the MCP joints, and 0.22 to 0.66 for PIP joints.</p><p><strong>Discussion: </strong>The automated system resulted in rapid data acquisition, with reliability varying by type of joint and location. It has the potential to improve efficiency in the collection of physical exam findings. Further developments of the system are needed to measure thumb and distal phalangeal motions.</p>\",\"PeriodicalId\":43971,\"journal\":{\"name\":\"Hand Therapy\",\"volume\":\"27 3\",\"pages\":\"91-99\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10588428/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hand Therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/17589983221110916\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/6/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hand Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17589983221110916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/6/22 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

摘要

引言:数字运动范围(ROM)的自动测量可以提高报告的准确性并提高临床效率。我们假设,定制龙门架上的3D相机将产生与手动测角仪类似的ROM测量结果。方法:将一台安装在定制龙门架上的三维摄像机机械化,绕平台旋转200°。视频被处理为分割每个手指,并计算没有任何手部疾病或手术史的人的关节角度,以验证该系统。第二代原型随后在不同手部状况的人身上进行了评估。用角度计和自动化系统反复测量指骨间关节(MCP)和指骨间近端关节(PIP)的屈曲。计算手动和自动测量之间的平均差异以及组内相关系数(ICC)。结果:在初始验证中,获得了1488个手动和1488个自动联合测量,并改进了测量算法。在有手部疾病的人中,688个手动关节测量和688个自动关节测量进行了比较。平均采集时间为每只手7秒,数据处理需要额外的2-3秒。临床研究中手动和自动数据之间的ICC范围为MCP关节的0.65至0.85,PIP关节的0.22至0.66。讨论:自动化系统实现了快速的数据采集,可靠性因接头类型和位置而异。它有可能提高体检结果收集的效率。该系统的进一步发展需要测量拇指和远节指骨的运动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A system for automated acquisition of digital flexion using a 3-D camera and custom gantry.

Introduction: Automated measurement of digital range of motion (ROM) may improve the accuracy of reporting and increase clinical efficiency. We hypothesize that a 3-D camera on a custom gantry will produce ROM measurements similar to those obtained with a manual goniometer.

Methods: A 3-D camera mounted on a custom gantry, was mechanized to rotate 200° around a platform. The video was processed to segment each digit and calculate joint angles in people with no history of any hand conditions or surgery to validate the system. A second-generation prototype was then assessed in people with different hand conditions. Metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joint flexion were measured repeatedly with a goniometer and the automated system. The average difference between manual and automatic measurements was calculated along with intraclass correlation coefficients (ICC).

Results: In the initial validation, 1,488 manual and 1,488 automated joint measurements were obtained and the measurement algorithm was refined. In people with hand conditions, 688 manual and 688 automated joint measurements were compared. Average acquisition time was 7 s per hand, with an additional 2-3 s required for data processing. ICC between manual and automated data in the clinical study ranged from 0.65 to 0.85 for the MCP joints, and 0.22 to 0.66 for PIP joints.

Discussion: The automated system resulted in rapid data acquisition, with reliability varying by type of joint and location. It has the potential to improve efficiency in the collection of physical exam findings. Further developments of the system are needed to measure thumb and distal phalangeal motions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Hand Therapy
Hand Therapy REHABILITATION-
CiteScore
1.60
自引率
10.00%
发文量
13
期刊最新文献
The role of early orthotic intervention in the management of post-traumatic elbow contractures: Study protocol for phase II double-blinded randomised controlled trial. Trapeziometacarpal total joint arthroplasty, with or without supervised hand rehabilitation: A quasi-experimental trial. A scoping review to map public-facing websites for non-traumatic wrist disorders with quality evaluation. The effect of preoperative interventions on postoperative outcomes following elective hand surgery: A systematic review. A survey of practice on the use of condition-specific patient reported outcome measures with patients who have distal radius fractures.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1