在单一中心的真实世界人群中对薄支柱BioMime冠状动脉支架系统的长期评估:一项回顾性观察研究。

IF 1.4 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Cardiology Research Pub Date : 2023-10-01 Epub Date: 2023-10-21 DOI:10.14740/cr1515
Girish Meennahalli Palleda, Mohit Gupta, Ankit Bansal, Vishal Batra, Sanjay Tyagi, Shekhar Kunal
{"title":"在单一中心的真实世界人群中对薄支柱BioMime冠状动脉支架系统的长期评估:一项回顾性观察研究。","authors":"Girish Meennahalli Palleda, Mohit Gupta, Ankit Bansal, Vishal Batra, Sanjay Tyagi, Shekhar Kunal","doi":"10.14740/cr1515","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The short-term clinical outcomes of first-generation thicker-strut durable polymer-based drug-eluting stents (DES) have been widely examined. However, there is a scarcity on qualitative research on the long-term usage of DES that evaluated the thinner strut biodegradable stents for coronary artery disease. Hence, we sought to investigate the long-term safety and performance of thinner strut biodegradable polymer-based BioMime sirolimus-eluting coronary stent system in real-world patients with symptomatic ischemic heart disease.</p><p><strong>Methods: </strong>This was a retrospective, observational, single-center, post-marketing clinical follow-up study. The primary endpoints were the incidence of major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction (MI) attributed to target vessel revascularization (TVR), and target lesion revascularization (TLR) at 1-, 2-, 3- and 4-year follow-ups. The secondary endpoints were cardiac death, MI, TLR, TVR, device and procedural success rates, and stent thrombosis (ST).</p><p><strong>Results: </strong>In all, 1,188 consecutive patients were enrolled, and 1,333 (1,257 <i>de novo</i> and 76 in-stent restenotic lesions) out of 1,565 lesions were treated with the study device. The mean age of patients was 53.26 ± 10.31 years and 86.2% were male. The quantitative coronary angiographic derived mean lesion length and diameter were 29.62 ± 9.62 mm and 3.01 ± 0.29 mm, respectively. The average length and diameter of the study device implanted were 30.89 ± 6.31 mm and 3.17 ± 0.25 mm, respectively. The cumulative incidence of MACE at 1-, 2-, 3-, and 4 years was 0.61%, 1.47%, 2.08%, and 3.40%, respectively, and cumulative deaths due to cardiac causes were 0.61%, 1.13%, 1.22%, and 1.83%, respectively. There were no cases of TLR or TVR at 1-year follow-up. The cumulative rate of TLR at 2-, 3-, and 4 years was 0.35%, 0.87%, and 1.57%, respectively, while that of TVR was 0.61%, 1.47%, and 2.35%, respectively. Three (0.3%) incidences of probable ST occurred during the 6-month follow-up; no new cases were reported further. In subgroup analysis, MACEs were comparable across the long- and short-length stent groups through 4-year follow-up.</p><p><strong>Conclusions: </strong>This long-term study demonstrates the safety and performance of the ultra-thin BioMime sirolimus-eluting stent with satisfactory clinical outcomes in patients with symptomatic ischemic heart disease in real-world scenario.</p>","PeriodicalId":9424,"journal":{"name":"Cardiology Research","volume":"14 5","pages":"360-369"},"PeriodicalIF":1.4000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627375/pdf/","citationCount":"0","resultStr":"{\"title\":\"Long-Term Assessment of Thin-Strut BioMime Coronary Stent System in Real-World Population at Single-Center: A Retrospective Observational Study.\",\"authors\":\"Girish Meennahalli Palleda, Mohit Gupta, Ankit Bansal, Vishal Batra, Sanjay Tyagi, Shekhar Kunal\",\"doi\":\"10.14740/cr1515\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The short-term clinical outcomes of first-generation thicker-strut durable polymer-based drug-eluting stents (DES) have been widely examined. However, there is a scarcity on qualitative research on the long-term usage of DES that evaluated the thinner strut biodegradable stents for coronary artery disease. Hence, we sought to investigate the long-term safety and performance of thinner strut biodegradable polymer-based BioMime sirolimus-eluting coronary stent system in real-world patients with symptomatic ischemic heart disease.</p><p><strong>Methods: </strong>This was a retrospective, observational, single-center, post-marketing clinical follow-up study. The primary endpoints were the incidence of major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction (MI) attributed to target vessel revascularization (TVR), and target lesion revascularization (TLR) at 1-, 2-, 3- and 4-year follow-ups. The secondary endpoints were cardiac death, MI, TLR, TVR, device and procedural success rates, and stent thrombosis (ST).</p><p><strong>Results: </strong>In all, 1,188 consecutive patients were enrolled, and 1,333 (1,257 <i>de novo</i> and 76 in-stent restenotic lesions) out of 1,565 lesions were treated with the study device. The mean age of patients was 53.26 ± 10.31 years and 86.2% were male. The quantitative coronary angiographic derived mean lesion length and diameter were 29.62 ± 9.62 mm and 3.01 ± 0.29 mm, respectively. The average length and diameter of the study device implanted were 30.89 ± 6.31 mm and 3.17 ± 0.25 mm, respectively. The cumulative incidence of MACE at 1-, 2-, 3-, and 4 years was 0.61%, 1.47%, 2.08%, and 3.40%, respectively, and cumulative deaths due to cardiac causes were 0.61%, 1.13%, 1.22%, and 1.83%, respectively. There were no cases of TLR or TVR at 1-year follow-up. The cumulative rate of TLR at 2-, 3-, and 4 years was 0.35%, 0.87%, and 1.57%, respectively, while that of TVR was 0.61%, 1.47%, and 2.35%, respectively. Three (0.3%) incidences of probable ST occurred during the 6-month follow-up; no new cases were reported further. In subgroup analysis, MACEs were comparable across the long- and short-length stent groups through 4-year follow-up.</p><p><strong>Conclusions: </strong>This long-term study demonstrates the safety and performance of the ultra-thin BioMime sirolimus-eluting stent with satisfactory clinical outcomes in patients with symptomatic ischemic heart disease in real-world scenario.</p>\",\"PeriodicalId\":9424,\"journal\":{\"name\":\"Cardiology Research\",\"volume\":\"14 5\",\"pages\":\"360-369\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10627375/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiology Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14740/cr1515\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14740/cr1515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/21 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:第一代较厚支柱耐用聚合物药物洗脱支架(DES)的短期临床结果已得到广泛检查。然而,很少对DES的长期使用进行定性研究,以评估较薄的可生物降解支架治疗冠状动脉疾病。因此,我们试图研究基于更薄支柱可生物降解聚合物的BioMime西罗莫司洗脱冠状动脉支架系统在现实世界中有症状的缺血性心脏病患者中的长期安全性和性能。方法:这是一项回顾性、观察性、单中心、上市后临床随访研究。主要终点是1年、2年、3年和4年随访时主要心脏不良事件(MACE)的发生率,MACE被定义为心脏死亡、靶血管血运重建(TVR)引起的心肌梗死(MI)和靶病变血运重建术(TLR)的复合。次要终点为心脏死亡、MI、TLR、TVR、器械和手术成功率以及支架血栓形成(ST)。结果:总共有1188名连续患者入选,1565个病变中有1333个(1257个为新发病变,76个为支架内再狭窄病变)接受了该研究装置的治疗。患者平均年龄为53.26±10.31岁,男性占86.2%。定量冠状动脉造影得出的平均病变长度和直径分别为29.62±9.62 mm和3.01±0.29 mm。植入的研究装置的平均长度和直径分别为30.89±6.31 mm和3.17±0.25 mm。MACE在1年、2年、3年和4年的累计发病率分别为0.61%、1.47%、2.08%和3.40%,心脏原因导致的累计死亡分别为0.67%、1.13%、1.22%和1.83%。在1年的随访中,没有出现TLR或TVR病例。TLR在2年、3年和4年的累积率分别为0.35%、0.87%和1.57%,而TVR的累积率则分别为0.61%、1.47%和2.35%。在6个月的随访中发生了三次(0.3%)可能的ST段发生率;没有进一步报告新病例。在亚组分析中,通过4年的随访,长短长度支架组的MACE具有可比性。结论:这项长期研究证明了超薄BioMime西罗莫司洗脱支架的安全性和性能,在现实世界中,在症状性缺血性心脏病患者中具有令人满意的临床结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Long-Term Assessment of Thin-Strut BioMime Coronary Stent System in Real-World Population at Single-Center: A Retrospective Observational Study.

Background: The short-term clinical outcomes of first-generation thicker-strut durable polymer-based drug-eluting stents (DES) have been widely examined. However, there is a scarcity on qualitative research on the long-term usage of DES that evaluated the thinner strut biodegradable stents for coronary artery disease. Hence, we sought to investigate the long-term safety and performance of thinner strut biodegradable polymer-based BioMime sirolimus-eluting coronary stent system in real-world patients with symptomatic ischemic heart disease.

Methods: This was a retrospective, observational, single-center, post-marketing clinical follow-up study. The primary endpoints were the incidence of major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction (MI) attributed to target vessel revascularization (TVR), and target lesion revascularization (TLR) at 1-, 2-, 3- and 4-year follow-ups. The secondary endpoints were cardiac death, MI, TLR, TVR, device and procedural success rates, and stent thrombosis (ST).

Results: In all, 1,188 consecutive patients were enrolled, and 1,333 (1,257 de novo and 76 in-stent restenotic lesions) out of 1,565 lesions were treated with the study device. The mean age of patients was 53.26 ± 10.31 years and 86.2% were male. The quantitative coronary angiographic derived mean lesion length and diameter were 29.62 ± 9.62 mm and 3.01 ± 0.29 mm, respectively. The average length and diameter of the study device implanted were 30.89 ± 6.31 mm and 3.17 ± 0.25 mm, respectively. The cumulative incidence of MACE at 1-, 2-, 3-, and 4 years was 0.61%, 1.47%, 2.08%, and 3.40%, respectively, and cumulative deaths due to cardiac causes were 0.61%, 1.13%, 1.22%, and 1.83%, respectively. There were no cases of TLR or TVR at 1-year follow-up. The cumulative rate of TLR at 2-, 3-, and 4 years was 0.35%, 0.87%, and 1.57%, respectively, while that of TVR was 0.61%, 1.47%, and 2.35%, respectively. Three (0.3%) incidences of probable ST occurred during the 6-month follow-up; no new cases were reported further. In subgroup analysis, MACEs were comparable across the long- and short-length stent groups through 4-year follow-up.

Conclusions: This long-term study demonstrates the safety and performance of the ultra-thin BioMime sirolimus-eluting stent with satisfactory clinical outcomes in patients with symptomatic ischemic heart disease in real-world scenario.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cardiology Research
Cardiology Research CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.50
自引率
0.00%
发文量
42
期刊介绍: Cardiology Research is an open access, peer-reviewed, international journal. All submissions relating to basic research and clinical practice of cardiology and cardiovascular medicine are in this journal''s scope. This journal focuses on publishing original research and observations in all cardiovascular medicine aspects. Manuscript types include original article, review, case report, short communication, book review, letter to the editor.
期刊最新文献
Advances in the Understanding and Treatment of Chronic Chagas Cardiomyopathy. Detection of Left Atrial Remodeling by Three-Dimensional Echocardiography in Symptomatic Patients Known to Had Non-Obstructive Hypertrophic Cardiomyopathy. Diverse Concepts in Definitions of Dilated Cardiomyopathy: Theory and Practice. Effect of Post-Loop Diuretic Urinary Sodium Level on Length of Stay and Rehospitalization in Acutely Decompensated Heart Failure Patients. Evaluating the Prognostic Value of the Modified H2FPEF Score in Patients With Heart Failure With Preserved Ejection Fraction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1