{"title":"计算机断层扫描引导下亚厘米肺结节活检:一项荟萃分析。","authors":"Jin-Ling Feng, Yu-Fei Fu, Yu Li","doi":"10.5114/kitp.2023.131947","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Pulmonary nodules (PNs) with a diameter from 5 to 10 mm exhibit malignancy rates anywhere from 47.5 to 61.5%. Despite the potential danger posed by these lesions, their small size makes the biopsy of these sub-centimetre (≤ 10 mm) PNs under computed tomography (CT) guidance very difficult.</p><p><strong>Aim: </strong>A meta-analysis was performed with the goal of evaluating the safety and diagnostic utility of CT-guided biopsy procedures for sub-centimetre PNs.</p><p><strong>Material and methods: </strong>Relevant studies published through April 2023 were identified in the PubMed, Web of Science, and Wanfang databases and used to conduct pooled analyses of selected endpoints, including technical success, diagnostic yield, diagnostic accuracy, pulmonary haemorrhage, and pneumothorax rates.</p><p><strong>Results: </strong>In total, this meta-analysis incorporated 10 studies in which 1482 patients with sub-centimetre PNs underwent CT-guided biopsy procedures. Among these patients, the respective pooled rates of technical success, diagnostic yield, diagnostic accuracy, pulmonary haemorrhage, and pneumothorax were 90%, 60%, 91%, 11%, and 24%, and significant heterogeneity was detected for all of these endpoints (<i>I</i><sup>2</sup> = 93.6%, 96%, 76.9%, 80.8%, and 93.6%). A substantial difference in diagnostic accuracy was observed when comparing biopsy procedures performed using fine- and core-needle biopsy approaches (85% vs. 95%), whereas the use of the co-axial method or the selected guidance approach (conventional vs. cone-beam CT) had no impact on diagnostic accuracy. Needle type, guidance method, and co-axial method use had no impact on the rates of pulmonary haemorrhage or pneumothorax.</p><p><strong>Conclusions: </strong>CT-guided biopsy represents a safe and effective means of accurately diagnosing sub-centimetre PNs.</p>","PeriodicalId":49945,"journal":{"name":"Kardiochirurgia I Torakochirurgia Polska","volume":"20 3","pages":"139-145"},"PeriodicalIF":0.6000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10626403/pdf/","citationCount":"0","resultStr":"{\"title\":\"Computed tomography-guided biopsy for sub-centimetre pulmonary nodules: a meta-analysis.\",\"authors\":\"Jin-Ling Feng, Yu-Fei Fu, Yu Li\",\"doi\":\"10.5114/kitp.2023.131947\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Pulmonary nodules (PNs) with a diameter from 5 to 10 mm exhibit malignancy rates anywhere from 47.5 to 61.5%. Despite the potential danger posed by these lesions, their small size makes the biopsy of these sub-centimetre (≤ 10 mm) PNs under computed tomography (CT) guidance very difficult.</p><p><strong>Aim: </strong>A meta-analysis was performed with the goal of evaluating the safety and diagnostic utility of CT-guided biopsy procedures for sub-centimetre PNs.</p><p><strong>Material and methods: </strong>Relevant studies published through April 2023 were identified in the PubMed, Web of Science, and Wanfang databases and used to conduct pooled analyses of selected endpoints, including technical success, diagnostic yield, diagnostic accuracy, pulmonary haemorrhage, and pneumothorax rates.</p><p><strong>Results: </strong>In total, this meta-analysis incorporated 10 studies in which 1482 patients with sub-centimetre PNs underwent CT-guided biopsy procedures. Among these patients, the respective pooled rates of technical success, diagnostic yield, diagnostic accuracy, pulmonary haemorrhage, and pneumothorax were 90%, 60%, 91%, 11%, and 24%, and significant heterogeneity was detected for all of these endpoints (<i>I</i><sup>2</sup> = 93.6%, 96%, 76.9%, 80.8%, and 93.6%). A substantial difference in diagnostic accuracy was observed when comparing biopsy procedures performed using fine- and core-needle biopsy approaches (85% vs. 95%), whereas the use of the co-axial method or the selected guidance approach (conventional vs. cone-beam CT) had no impact on diagnostic accuracy. Needle type, guidance method, and co-axial method use had no impact on the rates of pulmonary haemorrhage or pneumothorax.</p><p><strong>Conclusions: </strong>CT-guided biopsy represents a safe and effective means of accurately diagnosing sub-centimetre PNs.</p>\",\"PeriodicalId\":49945,\"journal\":{\"name\":\"Kardiochirurgia I Torakochirurgia Polska\",\"volume\":\"20 3\",\"pages\":\"139-145\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10626403/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kardiochirurgia I Torakochirurgia Polska\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5114/kitp.2023.131947\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kardiochirurgia I Torakochirurgia Polska","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/kitp.2023.131947","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/30 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

引言:直径为5至10毫米的肺结节(PNs)的恶性率在47.5%至61.5%之间。尽管这些病变带来了潜在的危险,但它们的小尺寸使在计算机断层扫描(CT)指导下对这些亚厘米(≤10毫米)的PNs进行活组织检查变得非常困难。目的:进行一项荟萃分析,目的是评估CT引导的亚厘米PNs活检程序的安全性和诊断实用性。材料和方法:截至2023年4月发表的相关研究已在PubMed、Web of Science和Wanfang数据库中确定,并用于对选定的终点进行汇总分析,包括技术成功率、诊断率,诊断准确率、肺出血率和肺气肿发生率。结果:本荟萃分析总共纳入了10项研究,其中1482名亚厘米PNs患者接受了CT引导的活检程序。在这些患者中,技术成功率、诊断率、诊断准确率、肺出血和肺气肿的综合比率分别为90%、60%、91%、11%和24%,所有这些终点都检测到显著的异质性(I2=93.6%、96%、76.9%、80.8%和93.6%)。当比较使用细针和核心针活检方法进行的活检程序时,观察到诊断准确性的显著差异(85%对95%),而同轴方法或选择的引导方法(传统与锥形束CT)的使用对诊断准确性没有影响。针型、引导方法和同轴方法的使用对肺出血或肺气肿的发生率没有影响。结论:CT引导下活检是准确诊断亚厘米PNs的一种安全有效的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Computed tomography-guided biopsy for sub-centimetre pulmonary nodules: a meta-analysis.

Introduction: Pulmonary nodules (PNs) with a diameter from 5 to 10 mm exhibit malignancy rates anywhere from 47.5 to 61.5%. Despite the potential danger posed by these lesions, their small size makes the biopsy of these sub-centimetre (≤ 10 mm) PNs under computed tomography (CT) guidance very difficult.

Aim: A meta-analysis was performed with the goal of evaluating the safety and diagnostic utility of CT-guided biopsy procedures for sub-centimetre PNs.

Material and methods: Relevant studies published through April 2023 were identified in the PubMed, Web of Science, and Wanfang databases and used to conduct pooled analyses of selected endpoints, including technical success, diagnostic yield, diagnostic accuracy, pulmonary haemorrhage, and pneumothorax rates.

Results: In total, this meta-analysis incorporated 10 studies in which 1482 patients with sub-centimetre PNs underwent CT-guided biopsy procedures. Among these patients, the respective pooled rates of technical success, diagnostic yield, diagnostic accuracy, pulmonary haemorrhage, and pneumothorax were 90%, 60%, 91%, 11%, and 24%, and significant heterogeneity was detected for all of these endpoints (I2 = 93.6%, 96%, 76.9%, 80.8%, and 93.6%). A substantial difference in diagnostic accuracy was observed when comparing biopsy procedures performed using fine- and core-needle biopsy approaches (85% vs. 95%), whereas the use of the co-axial method or the selected guidance approach (conventional vs. cone-beam CT) had no impact on diagnostic accuracy. Needle type, guidance method, and co-axial method use had no impact on the rates of pulmonary haemorrhage or pneumothorax.

Conclusions: CT-guided biopsy represents a safe and effective means of accurately diagnosing sub-centimetre PNs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.90
自引率
14.30%
发文量
44
审稿时长
6-12 weeks
期刊介绍: Polish Journal of Thoracic and Cardiovascular Surgery is a quarterly aimed at cardiologists, cardiosurgeons and thoracic surgeons. Includes the original works (experimental, research and development), illustrative and casuistical works about cardiology and cardiosurgery.
期刊最新文献
Clinicodemographic profile and outcomes of congenital diaphragmatic hernia with sac: experience of a paediatric referral centre. Comparison of the effect of chest tube diameter on drainage rate and tube performance in patients with pleural effusion. A cross-sectional study. Enhancing treatment approaches for postpneumonectomy empyema: exploring the role of video-assisted thoracic surgery. Optimal timing of percutaneous coronary intervention in elderly patients with acute ST-segment elevation myocardial infarction presenting late. Perceval sutureless bioprosthesis versus Trifecta sutured bioprosthesis for aortic valve replacement: immediate results of the Perfecta study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1