支架辅助绕线的前循环位置特异性结果-颈动脉瘤与远端动脉瘤:Neuroform Atlas支架枢轴试验的1年结果。

IF 4.5 1区 医学 Q1 NEUROIMAGING Journal of NeuroInterventional Surgery Pub Date : 2024-10-14 DOI:10.1136/jnis-2023-020591
Ricardo A Hanel, Gustavo M Cortez, Brian T Jankowitz, Eric Sauvageau, Amin Aghaebrahim, Eugene Lin, Ashutosh P Jadhav, Bradley Gross, Ahmad Khaldi, Rishi Gupta, Donald Frei, David Loy, Lori Lyn Price, Steven W Hetts, Osama O Zaidat
{"title":"支架辅助绕线的前循环位置特异性结果-颈动脉瘤与远端动脉瘤:Neuroform Atlas支架枢轴试验的1年结果。","authors":"Ricardo A Hanel, Gustavo M Cortez, Brian T Jankowitz, Eric Sauvageau, Amin Aghaebrahim, Eugene Lin, Ashutosh P Jadhav, Bradley Gross, Ahmad Khaldi, Rishi Gupta, Donald Frei, David Loy, Lori Lyn Price, Steven W Hetts, Osama O Zaidat","doi":"10.1136/jnis-2023-020591","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Neuroform Atlas Stent System is an established treatment modality for unruptured anterior and posterior circulation intracranial aneurysms. Location-specific results are needed to guide treatment decision-making. However, it is unclear whether there are differences in safety and efficacy outcomes between carotid and more distal anterior circulation aneurysms.</p><p><strong>Methods: </strong>The ATLAS IDE trial was a prospective, multicenter, single-arm, open-label interventional study that evaluated the safety and efficacy of the Neuroform Atlas Stent System. We compared differences in efficacy and safety outcomes of proximal internal carotid artery (ICA) versus distal and bifurcation anterior circulation aneurysms.</p><p><strong>Results: </strong>Of 182 cases, there were 70 aneurysms in the ICA and 112 in the distal anterior circulation (including ICA terminus/bifurcation). There were no significant differences in the primary efficacy endpoint (85.5% vs 83.9%, p=0.78) and complete aneurysm occlusion rates (88.7% vs 87.9%, p=0.78) between proximal ICA aneurysms and distal aneurysms, respectively. Complications were more often encountered in distal and bifurcation aneurysms, but the overall rate of major safety events was low and comparable between the two groups (1.4% vs 6.3%, p=0.14). Recanalization and retreatment rates were also similar between the groups.</p><p><strong>Conclusion: </strong>The results of this study suggest that the Neuroform Atlas Stent System is a safe and efficacious treatment modality for unruptured anterior circulation intracranial aneurysms, regardless of aneurysm location.</p><p><strong>Trial registration number: </strong>NCT02340585.</p>","PeriodicalId":16411,"journal":{"name":"Journal of NeuroInterventional Surgery","volume":" ","pages":"1125-1130"},"PeriodicalIF":4.5000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11503183/pdf/","citationCount":"0","resultStr":"{\"title\":\"Anterior circulation location-specific results for stent-assisted coiling - carotid versus distal aneurysms: 1-year outcomes from the Neuroform Atlas Stent Pivotal Trial.\",\"authors\":\"Ricardo A Hanel, Gustavo M Cortez, Brian T Jankowitz, Eric Sauvageau, Amin Aghaebrahim, Eugene Lin, Ashutosh P Jadhav, Bradley Gross, Ahmad Khaldi, Rishi Gupta, Donald Frei, David Loy, Lori Lyn Price, Steven W Hetts, Osama O Zaidat\",\"doi\":\"10.1136/jnis-2023-020591\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The Neuroform Atlas Stent System is an established treatment modality for unruptured anterior and posterior circulation intracranial aneurysms. Location-specific results are needed to guide treatment decision-making. However, it is unclear whether there are differences in safety and efficacy outcomes between carotid and more distal anterior circulation aneurysms.</p><p><strong>Methods: </strong>The ATLAS IDE trial was a prospective, multicenter, single-arm, open-label interventional study that evaluated the safety and efficacy of the Neuroform Atlas Stent System. We compared differences in efficacy and safety outcomes of proximal internal carotid artery (ICA) versus distal and bifurcation anterior circulation aneurysms.</p><p><strong>Results: </strong>Of 182 cases, there were 70 aneurysms in the ICA and 112 in the distal anterior circulation (including ICA terminus/bifurcation). There were no significant differences in the primary efficacy endpoint (85.5% vs 83.9%, p=0.78) and complete aneurysm occlusion rates (88.7% vs 87.9%, p=0.78) between proximal ICA aneurysms and distal aneurysms, respectively. Complications were more often encountered in distal and bifurcation aneurysms, but the overall rate of major safety events was low and comparable between the two groups (1.4% vs 6.3%, p=0.14). Recanalization and retreatment rates were also similar between the groups.</p><p><strong>Conclusion: </strong>The results of this study suggest that the Neuroform Atlas Stent System is a safe and efficacious treatment modality for unruptured anterior circulation intracranial aneurysms, regardless of aneurysm location.</p><p><strong>Trial registration number: </strong>NCT02340585.</p>\",\"PeriodicalId\":16411,\"journal\":{\"name\":\"Journal of NeuroInterventional Surgery\",\"volume\":\" \",\"pages\":\"1125-1130\"},\"PeriodicalIF\":4.5000,\"publicationDate\":\"2024-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11503183/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of NeuroInterventional Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1136/jnis-2023-020591\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"NEUROIMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of NeuroInterventional Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/jnis-2023-020591","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:Neuroform Atlas支架系统是一种已建立的治疗未破裂的前循环和后循环颅内动脉瘤的方法。需要特定位置的结果来指导治疗决策。然而,目前尚不清楚颈动脉瘤和远端前循环动脉瘤在安全性和疗效方面是否存在差异。方法:ATLAS IDE试验是一项前瞻性、多中心、单臂、开放标签的介入研究,旨在评估Neuroform ATLAS支架系统的安全性和有效性。我们比较了近端颈内动脉(ICA)与远端和分叉前循环动脉瘤的疗效和安全性结果的差异。结果:182例中,颈内动脉瘤70例,前循环远端(包括颈内动脉末端/分叉)112例。近端ICA动脉瘤和远端动脉瘤的主要疗效终点(85.5%vs 83.9%,p=0.78)和完全动脉瘤闭塞率(88.7%vs 87.9%,p=0.78)分别无显著差异。并发症在远端和分叉动脉瘤中更常见,但主要安全事件的总体发生率较低,两组之间具有可比性(1.4%对6.3%,p=0.014)。两组之间的再分析和再治疗率也相似。结论:本研究的结果表明,无论动脉瘤的位置如何,Neuroform Atlas支架系统都是治疗未破裂的前循环颅内动脉瘤的安全有效的方法。试验注册号:NCT02340585。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Anterior circulation location-specific results for stent-assisted coiling - carotid versus distal aneurysms: 1-year outcomes from the Neuroform Atlas Stent Pivotal Trial.

Background: The Neuroform Atlas Stent System is an established treatment modality for unruptured anterior and posterior circulation intracranial aneurysms. Location-specific results are needed to guide treatment decision-making. However, it is unclear whether there are differences in safety and efficacy outcomes between carotid and more distal anterior circulation aneurysms.

Methods: The ATLAS IDE trial was a prospective, multicenter, single-arm, open-label interventional study that evaluated the safety and efficacy of the Neuroform Atlas Stent System. We compared differences in efficacy and safety outcomes of proximal internal carotid artery (ICA) versus distal and bifurcation anterior circulation aneurysms.

Results: Of 182 cases, there were 70 aneurysms in the ICA and 112 in the distal anterior circulation (including ICA terminus/bifurcation). There were no significant differences in the primary efficacy endpoint (85.5% vs 83.9%, p=0.78) and complete aneurysm occlusion rates (88.7% vs 87.9%, p=0.78) between proximal ICA aneurysms and distal aneurysms, respectively. Complications were more often encountered in distal and bifurcation aneurysms, but the overall rate of major safety events was low and comparable between the two groups (1.4% vs 6.3%, p=0.14). Recanalization and retreatment rates were also similar between the groups.

Conclusion: The results of this study suggest that the Neuroform Atlas Stent System is a safe and efficacious treatment modality for unruptured anterior circulation intracranial aneurysms, regardless of aneurysm location.

Trial registration number: NCT02340585.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
9.50
自引率
14.60%
发文量
291
审稿时长
4-8 weeks
期刊介绍: The Journal of NeuroInterventional Surgery (JNIS) is a leading peer review journal for scientific research and literature pertaining to the field of neurointerventional surgery. The journal launch follows growing professional interest in neurointerventional techniques for the treatment of a range of neurological and vascular problems including stroke, aneurysms, brain tumors, and spinal compression.The journal is owned by SNIS and is also the official journal of the Interventional Chapter of the Australian and New Zealand Society of Neuroradiology (ANZSNR), the Canadian Interventional Neuro Group, the Hong Kong Neurological Society (HKNS) and the Neuroradiological Society of Taiwan.
期刊最新文献
Burden of incidental cerebral aneurysms on lifestyle and quality of life: a survey of patients in expectant management (the SPICE Study). Comprehensive evaluation of management strategies and rupture status in partially thrombosed aneurysms: a systematic review and meta-analysis. Correspondence on: 'Comparative analysis of single plane and biplane angiography systems for mechanical thrombectomy for acute ischemic stroke: a systematic review and meta-analysis' by Orscelik et al. Evaluating the effects of recreational drug use on ruptured cerebral arteriovenous malformation presentation and in-hospital outcomes: a national inpatient sample analysis. Introduction of neurointerventional services, including mechanical thrombectomy, to a resource limited setting in Tanzania.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1