{"title":"独立芯法——测定水分含量的新技术","authors":"A.J. Newman","doi":"10.1016/0007-3628(74)90030-9","DOIUrl":null,"url":null,"abstract":"<div><p>This article describes a new method for the accurate measurement of moisture in porous walls which are exposed to normal weathering processes, i.e. wetting by rain and subsequent drying. With small adaptations, it could be used for other structures.</p><p>In a field test, the method has been used to follow the drying of a 2·1 m high cavity wall.</p></div>","PeriodicalId":9442,"journal":{"name":"Building Science","volume":"9 4","pages":"Pages 309-313"},"PeriodicalIF":0.0000,"publicationDate":"1974-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0007-3628(74)90030-9","citationCount":"3","resultStr":"{\"title\":\"The independent core method—A new technique for the determination of moisture content\",\"authors\":\"A.J. Newman\",\"doi\":\"10.1016/0007-3628(74)90030-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This article describes a new method for the accurate measurement of moisture in porous walls which are exposed to normal weathering processes, i.e. wetting by rain and subsequent drying. With small adaptations, it could be used for other structures.</p><p>In a field test, the method has been used to follow the drying of a 2·1 m high cavity wall.</p></div>\",\"PeriodicalId\":9442,\"journal\":{\"name\":\"Building Science\",\"volume\":\"9 4\",\"pages\":\"Pages 309-313\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1974-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0007-3628(74)90030-9\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Building Science\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0007362874900309\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building Science","FirstCategoryId":"1087","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0007362874900309","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The independent core method—A new technique for the determination of moisture content
This article describes a new method for the accurate measurement of moisture in porous walls which are exposed to normal weathering processes, i.e. wetting by rain and subsequent drying. With small adaptations, it could be used for other structures.
In a field test, the method has been used to follow the drying of a 2·1 m high cavity wall.