{"title":"一种用于脊髓磁刺激植入式应用的微制造线圈。","authors":"Yu-Min Fu, Che-Yu Chen, Xin-Hong Qian, Yu-Ting Cheng, Chung-Yu Wu, Jui-Sheng Sun, Chien-Chun Huang, Chao-Kai Hu","doi":"10.1109/EMBC.2015.7319982","DOIUrl":null,"url":null,"abstract":"In this paper, a microfabricated inductive coil comprising of 125-turn coil windings and a MnZn-based magnetic core in a volume of 200 mm(3) is presented for the magnetic neural stimulation in a spinal cord. The coil winding with the parallel-linkage design instead of the typical serial-linkage one is proposed not only to provide better design flexibility to the current mode driving circuit but also to simplify the fabrication process of the 3-D inductive coil, which can further advance the coil miniaturization. Experimental results show the microcoil with a 1.5 A, 1 kHz square-wave current input can induce a voltages of ~220 μV on the conducting wire with an impedance of ~0.2 Ω @ 1 kHz, 1 mm separation.","PeriodicalId":72689,"journal":{"name":"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference","volume":"59 4","pages":"6912-5"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/EMBC.2015.7319982","citationCount":"0","resultStr":"{\"title\":\"A microfabricated coil for implantable applications of magnetic spinal cord stimulation.\",\"authors\":\"Yu-Min Fu, Che-Yu Chen, Xin-Hong Qian, Yu-Ting Cheng, Chung-Yu Wu, Jui-Sheng Sun, Chien-Chun Huang, Chao-Kai Hu\",\"doi\":\"10.1109/EMBC.2015.7319982\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a microfabricated inductive coil comprising of 125-turn coil windings and a MnZn-based magnetic core in a volume of 200 mm(3) is presented for the magnetic neural stimulation in a spinal cord. The coil winding with the parallel-linkage design instead of the typical serial-linkage one is proposed not only to provide better design flexibility to the current mode driving circuit but also to simplify the fabrication process of the 3-D inductive coil, which can further advance the coil miniaturization. Experimental results show the microcoil with a 1.5 A, 1 kHz square-wave current input can induce a voltages of ~220 μV on the conducting wire with an impedance of ~0.2 Ω @ 1 kHz, 1 mm separation.\",\"PeriodicalId\":72689,\"journal\":{\"name\":\"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference\",\"volume\":\"59 4\",\"pages\":\"6912-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/EMBC.2015.7319982\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMBC.2015.7319982\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMBC.2015.7319982","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A microfabricated coil for implantable applications of magnetic spinal cord stimulation.
In this paper, a microfabricated inductive coil comprising of 125-turn coil windings and a MnZn-based magnetic core in a volume of 200 mm(3) is presented for the magnetic neural stimulation in a spinal cord. The coil winding with the parallel-linkage design instead of the typical serial-linkage one is proposed not only to provide better design flexibility to the current mode driving circuit but also to simplify the fabrication process of the 3-D inductive coil, which can further advance the coil miniaturization. Experimental results show the microcoil with a 1.5 A, 1 kHz square-wave current input can induce a voltages of ~220 μV on the conducting wire with an impedance of ~0.2 Ω @ 1 kHz, 1 mm separation.