内侧漏斗胸患者腹直肌移位伴硅胶模塑植入的矫正

IF 1.6 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Interactive cardiovascular and thoracic surgery Pub Date : 2022-05-30 DOI:10.1093/icvts/ivac147
J. Anger, J. M. D. de Campos
{"title":"内侧漏斗胸患者腹直肌移位伴硅胶模塑植入的矫正","authors":"J. Anger, J. M. D. de Campos","doi":"10.1093/icvts/ivac147","DOIUrl":null,"url":null,"abstract":"Abstract The association of the diastasis of the rectus abdominis muscle and the medial pectus excavatum was reported. We have been using soft silicone block, sculpted intraoperatively, to correct pectus excavatum. The horizontal access used, 2 cm at a subxiphoid position, allows us to expose the sternum and the rectus abdominis muscles (RAMs). We report a case, male, 31 years presenting medial pectus excavatum and supraumbilical diastasis of the rectus abdominis muscle with a width of 35 mm at the costal arches, and 27 mm at 6 cm from the xiphoid process edge. The muscle borders presented a curved lateral deviation up to the insertion in the costal arches. The necessary space for the implant was dissected and the block was sculpted. The medial and superior aponeurosis borders of the RAM were incised at 6 cm from the xiphoid, and the posterior border of the RAM was released. The aponeurosis borders were brought together, promoting a medial and anterior positioning of the RAM. The inferior border of the implant was attached to the raw superior borders of the RAM. The result was considered satisfactory, and a magnetic resonance image 14 months after showed continuity of the implant and the muscles, promoting a uniform body contour. Registry: CAAE63181616.7.0000.0071.","PeriodicalId":13621,"journal":{"name":"Interactive cardiovascular and thoracic surgery","volume":"45 5","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2022-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The correction of the diastasis of the rectus abdominis muscle concomitant with a moulded silicone implant insertion in a patient with medial pectus excavatum\",\"authors\":\"J. Anger, J. M. D. de Campos\",\"doi\":\"10.1093/icvts/ivac147\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The association of the diastasis of the rectus abdominis muscle and the medial pectus excavatum was reported. We have been using soft silicone block, sculpted intraoperatively, to correct pectus excavatum. The horizontal access used, 2 cm at a subxiphoid position, allows us to expose the sternum and the rectus abdominis muscles (RAMs). We report a case, male, 31 years presenting medial pectus excavatum and supraumbilical diastasis of the rectus abdominis muscle with a width of 35 mm at the costal arches, and 27 mm at 6 cm from the xiphoid process edge. The muscle borders presented a curved lateral deviation up to the insertion in the costal arches. The necessary space for the implant was dissected and the block was sculpted. The medial and superior aponeurosis borders of the RAM were incised at 6 cm from the xiphoid, and the posterior border of the RAM was released. The aponeurosis borders were brought together, promoting a medial and anterior positioning of the RAM. The inferior border of the implant was attached to the raw superior borders of the RAM. The result was considered satisfactory, and a magnetic resonance image 14 months after showed continuity of the implant and the muscles, promoting a uniform body contour. Registry: CAAE63181616.7.0000.0071.\",\"PeriodicalId\":13621,\"journal\":{\"name\":\"Interactive cardiovascular and thoracic surgery\",\"volume\":\"45 5\",\"pages\":\"\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2022-05-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interactive cardiovascular and thoracic surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/icvts/ivac147\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interactive cardiovascular and thoracic surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/icvts/ivac147","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

摘要本文报道了腹直肌移位与漏斗胸内侧肌移位的关系。我们一直使用软硅胶块,术中雕刻,矫正漏斗胸。在剑突下2厘米处采用水平入路,可以显露胸骨和腹直肌(RAMs)。我们报告一例男性,31岁,表现为漏斗胸内侧和脐上腹直肌分离,在肋弓处宽度为35毫米,在距剑突边缘6厘米处宽度为27毫米。肌肉边界呈弯曲的外侧偏离,直至肋弓的插入。解剖种植体所需的空间并雕刻砌块。在距剑突6 cm处切开RAM的内侧和上腱膜边界,并释放RAM的后缘。将腱膜边界聚集在一起,促进RAM的内侧和前部定位。植入物的下缘附着于RAM的上缘。结果令人满意,14个月后的磁共振图像显示植入物和肌肉的连续性,促进了均匀的身体轮廓。注册中心:CAAE63181616.7.0000.0071。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The correction of the diastasis of the rectus abdominis muscle concomitant with a moulded silicone implant insertion in a patient with medial pectus excavatum
Abstract The association of the diastasis of the rectus abdominis muscle and the medial pectus excavatum was reported. We have been using soft silicone block, sculpted intraoperatively, to correct pectus excavatum. The horizontal access used, 2 cm at a subxiphoid position, allows us to expose the sternum and the rectus abdominis muscles (RAMs). We report a case, male, 31 years presenting medial pectus excavatum and supraumbilical diastasis of the rectus abdominis muscle with a width of 35 mm at the costal arches, and 27 mm at 6 cm from the xiphoid process edge. The muscle borders presented a curved lateral deviation up to the insertion in the costal arches. The necessary space for the implant was dissected and the block was sculpted. The medial and superior aponeurosis borders of the RAM were incised at 6 cm from the xiphoid, and the posterior border of the RAM was released. The aponeurosis borders were brought together, promoting a medial and anterior positioning of the RAM. The inferior border of the implant was attached to the raw superior borders of the RAM. The result was considered satisfactory, and a magnetic resonance image 14 months after showed continuity of the implant and the muscles, promoting a uniform body contour. Registry: CAAE63181616.7.0000.0071.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Interactive cardiovascular and thoracic surgery
Interactive cardiovascular and thoracic surgery CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.30
自引率
0.00%
发文量
292
审稿时长
2-4 weeks
期刊介绍: Interactive CardioVascular and Thoracic Surgery (ICVTS) publishes scientific contributions in the field of cardiovascular and thoracic surgery, covering all aspects of surgery of the heart, vessels and the chest. The journal publishes a range of article types including: Best Evidence Topics; Brief Communications; Case Reports; Original Articles; State-of-the-Art; Work in Progress Report.
期刊最新文献
Local tumour residue after microwave ablation for lung cancer: a case report. Long-term outcomes of papillary muscle relocation anteriorly for functional mitral regurgitation. Postoperative aortic injury caused by a staple line formed during wedge resection of the lung. Surgical management of cardiac cystic echinococcosis in a paediatric patient: a case report. Congenital aortocaval fistula combined with patent ductus arteriosus in an infant: a case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1