Anna V. Shlyakhotka, Ekaterina K. Lyakhova, A. Sutyagina
{"title":"用阻抗心动图法测定脑卒中容量的装置设计","authors":"Anna V. Shlyakhotka, Ekaterina K. Lyakhova, A. Sutyagina","doi":"10.1109/EICONRUS.2018.8317313","DOIUrl":null,"url":null,"abstract":"In this study we analyzed the existing methods of determining of stroke volume, equations for impedance cardiography (ICG) and developed a device of impedance cardiograph device for the evaluation of cardiac output and stroke volume. The ICG has several advantages compared with other methods as it is non-invasive, suitable for continuous measurement, simple to perform and provides accurate results. The difference between the values obtained using the direct Fick (standart parameter for evaluation) and ICG methods does not vary in any systematic way. The developed device is portable, communicate with PC via Bluetooth. The device is based on the AD5933 which is integrated impedance meter, tetrapolar electrode configuration is used.","PeriodicalId":6562,"journal":{"name":"2018 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)","volume":"5 1","pages":"1225-1226"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design of a device for determining stroke volume by the impedance cardiography method\",\"authors\":\"Anna V. Shlyakhotka, Ekaterina K. Lyakhova, A. Sutyagina\",\"doi\":\"10.1109/EICONRUS.2018.8317313\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study we analyzed the existing methods of determining of stroke volume, equations for impedance cardiography (ICG) and developed a device of impedance cardiograph device for the evaluation of cardiac output and stroke volume. The ICG has several advantages compared with other methods as it is non-invasive, suitable for continuous measurement, simple to perform and provides accurate results. The difference between the values obtained using the direct Fick (standart parameter for evaluation) and ICG methods does not vary in any systematic way. The developed device is portable, communicate with PC via Bluetooth. The device is based on the AD5933 which is integrated impedance meter, tetrapolar electrode configuration is used.\",\"PeriodicalId\":6562,\"journal\":{\"name\":\"2018 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)\",\"volume\":\"5 1\",\"pages\":\"1225-1226\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EICONRUS.2018.8317313\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EICONRUS.2018.8317313","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of a device for determining stroke volume by the impedance cardiography method
In this study we analyzed the existing methods of determining of stroke volume, equations for impedance cardiography (ICG) and developed a device of impedance cardiograph device for the evaluation of cardiac output and stroke volume. The ICG has several advantages compared with other methods as it is non-invasive, suitable for continuous measurement, simple to perform and provides accurate results. The difference between the values obtained using the direct Fick (standart parameter for evaluation) and ICG methods does not vary in any systematic way. The developed device is portable, communicate with PC via Bluetooth. The device is based on the AD5933 which is integrated impedance meter, tetrapolar electrode configuration is used.