{"title":"固相微萃取-高效液相色谱法测定环境样品中铜(II","authors":"Varinder Kaur, Ashok Kumar Malik","doi":"10.1002/adic.200790113","DOIUrl":null,"url":null,"abstract":"<p>A highly sensitive solid phase microextraction – high performance liquid chromatographic method has been developed for the determination of copper(II) using morpholine-4-carbodithioate (MDTC) as an analytical reagent. The MDTC formed yellowish- brown species of copper(II) at a pH range of 2-9 and complex was sorbed onto PDMS fiber. The Cu(II)-MDTC complex shows maximum absorbance at 430 nm and can be separated on C18 column by using acetonitrile : water (80 : 20) at a flow rate of 1.0 ml min<sup>-1</sup>.The detection limit of method was found to be 0.51 μg L<sup>-1</sup>. The interference due to common metal ions were studied. The repeatability of the method was checked by finding the relative standard deviation. The developed method was successfully employed for the determination of copper(II) in different alloy samples and the results were compared with existing methods.</p>","PeriodicalId":8193,"journal":{"name":"Annali di chimica","volume":"97 11-12","pages":"1279-1290"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/adic.200790113","citationCount":"11","resultStr":"{\"title\":\"Development of Solid Phase Microextraction-High Performance Liquid Chromatographic Method for the Determination of Copper(II) in Environmental Samples Using Morpholine-4-Carbodithioate\",\"authors\":\"Varinder Kaur, Ashok Kumar Malik\",\"doi\":\"10.1002/adic.200790113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A highly sensitive solid phase microextraction – high performance liquid chromatographic method has been developed for the determination of copper(II) using morpholine-4-carbodithioate (MDTC) as an analytical reagent. The MDTC formed yellowish- brown species of copper(II) at a pH range of 2-9 and complex was sorbed onto PDMS fiber. The Cu(II)-MDTC complex shows maximum absorbance at 430 nm and can be separated on C18 column by using acetonitrile : water (80 : 20) at a flow rate of 1.0 ml min<sup>-1</sup>.The detection limit of method was found to be 0.51 μg L<sup>-1</sup>. The interference due to common metal ions were studied. The repeatability of the method was checked by finding the relative standard deviation. The developed method was successfully employed for the determination of copper(II) in different alloy samples and the results were compared with existing methods.</p>\",\"PeriodicalId\":8193,\"journal\":{\"name\":\"Annali di chimica\",\"volume\":\"97 11-12\",\"pages\":\"1279-1290\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/adic.200790113\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annali di chimica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/adic.200790113\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annali di chimica","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adic.200790113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11
摘要
建立了以4-碳二硫酸morpholin -4-carbodithioate (MDTC)为分析试剂,固相微萃取-高效液相色谱法测定铜(II)的方法。MDTC在2 ~ 9的pH范围内形成黄褐色的铜(II),配合物被吸附在PDMS纤维上。Cu(II)-MDTC配合物在430 nm处吸光度最大,可以在C18柱上用乙腈:水(80:20),流速为1.0 ml min-1分离。方法检出限为0.51 μg L-1。研究了普通金属离子的干扰。通过计算相对标准偏差,验证了方法的重复性。该方法成功地用于不同合金样品中铜(II)的测定,并与现有方法进行了比较。
Development of Solid Phase Microextraction-High Performance Liquid Chromatographic Method for the Determination of Copper(II) in Environmental Samples Using Morpholine-4-Carbodithioate
A highly sensitive solid phase microextraction – high performance liquid chromatographic method has been developed for the determination of copper(II) using morpholine-4-carbodithioate (MDTC) as an analytical reagent. The MDTC formed yellowish- brown species of copper(II) at a pH range of 2-9 and complex was sorbed onto PDMS fiber. The Cu(II)-MDTC complex shows maximum absorbance at 430 nm and can be separated on C18 column by using acetonitrile : water (80 : 20) at a flow rate of 1.0 ml min-1.The detection limit of method was found to be 0.51 μg L-1. The interference due to common metal ions were studied. The repeatability of the method was checked by finding the relative standard deviation. The developed method was successfully employed for the determination of copper(II) in different alloy samples and the results were compared with existing methods.