{"title":"高温电介质中的热激放电电流","authors":"G. Raju","doi":"10.1109/CEIDP.1989.69558","DOIUrl":null,"url":null,"abstract":"The measurement of TSD (thermally stimulated discharge) currents in Nomex is reported. The TSD currents were measured by heating the sample at a uniform rate. Both the temperature and the current were measured using a strip chart recorder having a sensitivity of 2 mu V/mm and 10/sup -14/ A/mm, respectively. Detailed results are presented.<<ETX>>","PeriodicalId":10719,"journal":{"name":"Conference on Electrical Insulation and Dielectric Phenomena,","volume":"30 1","pages":"272-277"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Thermally stimulated discharge currents in high temperature dielectrics\",\"authors\":\"G. Raju\",\"doi\":\"10.1109/CEIDP.1989.69558\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The measurement of TSD (thermally stimulated discharge) currents in Nomex is reported. The TSD currents were measured by heating the sample at a uniform rate. Both the temperature and the current were measured using a strip chart recorder having a sensitivity of 2 mu V/mm and 10/sup -14/ A/mm, respectively. Detailed results are presented.<<ETX>>\",\"PeriodicalId\":10719,\"journal\":{\"name\":\"Conference on Electrical Insulation and Dielectric Phenomena,\",\"volume\":\"30 1\",\"pages\":\"272-277\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference on Electrical Insulation and Dielectric Phenomena,\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1989.69558\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Electrical Insulation and Dielectric Phenomena,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1989.69558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
报道了在Nomex测量TSD(热激放电)电流。以均匀速率加热样品,测量TSD电流。温度和电流均使用灵敏度分别为2 μ V/mm和10/sup -14/ a /mm的条形图记录仪进行测量。给出了详细的结果。
Thermally stimulated discharge currents in high temperature dielectrics
The measurement of TSD (thermally stimulated discharge) currents in Nomex is reported. The TSD currents were measured by heating the sample at a uniform rate. Both the temperature and the current were measured using a strip chart recorder having a sensitivity of 2 mu V/mm and 10/sup -14/ A/mm, respectively. Detailed results are presented.<>