{"title":"用局部放电试验研究固体介质降解","authors":"P. Sreejaya","doi":"10.1109/CEIDP.2008.4772853","DOIUrl":null,"url":null,"abstract":"Partial Discharge (PD) measurement and characterization provide vital information on insulation condition, different aspects of insulation ageing useful for equipment integrity verification and diagnosis. The PD denotes the Life vs. Stress characteristics of the material. The PD phenomenon is manifested as observable electric pulses. The work demonstrates the principle of PD measurement with the aid of an Off-line test arrangement. This paper investigates on the PD Inception and Extinction Voltage and determines the apparent charge, discharge energy and power dissipation for discharge quantity at a specified voltage. PD detection and measurement procedures suitable for use on Surge Arresters, Current Transformers and Insulators are examined.","PeriodicalId":6381,"journal":{"name":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"16 1","pages":"408-412"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Study of Solid Dielectric Degradation Using Partial Discharge Test\",\"authors\":\"P. Sreejaya\",\"doi\":\"10.1109/CEIDP.2008.4772853\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Partial Discharge (PD) measurement and characterization provide vital information on insulation condition, different aspects of insulation ageing useful for equipment integrity verification and diagnosis. The PD denotes the Life vs. Stress characteristics of the material. The PD phenomenon is manifested as observable electric pulses. The work demonstrates the principle of PD measurement with the aid of an Off-line test arrangement. This paper investigates on the PD Inception and Extinction Voltage and determines the apparent charge, discharge energy and power dissipation for discharge quantity at a specified voltage. PD detection and measurement procedures suitable for use on Surge Arresters, Current Transformers and Insulators are examined.\",\"PeriodicalId\":6381,\"journal\":{\"name\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"16 1\",\"pages\":\"408-412\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2008.4772853\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2008.4772853","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Study of Solid Dielectric Degradation Using Partial Discharge Test
Partial Discharge (PD) measurement and characterization provide vital information on insulation condition, different aspects of insulation ageing useful for equipment integrity verification and diagnosis. The PD denotes the Life vs. Stress characteristics of the material. The PD phenomenon is manifested as observable electric pulses. The work demonstrates the principle of PD measurement with the aid of an Off-line test arrangement. This paper investigates on the PD Inception and Extinction Voltage and determines the apparent charge, discharge energy and power dissipation for discharge quantity at a specified voltage. PD detection and measurement procedures suitable for use on Surge Arresters, Current Transformers and Insulators are examined.