LHD控制区门禁系统运行结果报告

T. Kawano, Y. Narushima
{"title":"LHD控制区门禁系统运行结果报告","authors":"T. Kawano, Y. Narushima","doi":"10.12950/RSM2002.2.17","DOIUrl":null,"url":null,"abstract":"An access-control system has been developed for the safety operation of the large helical device(LHD)at the National Institute for Fusion Science.The central part of the control system consists of a main computer,a manual-operation box and a sequencer-control system.The system monitors five turnstiles,eight shielding doors and other points of entry and directly supplies the interlock signals to the LHD control system.The sequencer-control system,which provides independent access control of each gate,is effective to control simultaneously all of the entry according to the status of the LHD and to permit the access of radiation workers belonging to a specific work group according to the situation of LHD plasma experiment.The safety management of LHD experiments has been performed without any serious troubles by this access control system including the interlock system since 1998.","PeriodicalId":7974,"journal":{"name":"Annual Report of National Institute for Fusion Science","volume":"23 1","pages":"448"},"PeriodicalIF":0.0000,"publicationDate":"2011-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Report of Operational Results of an Access Control System Developed for LHD Controlled Area\",\"authors\":\"T. Kawano, Y. Narushima\",\"doi\":\"10.12950/RSM2002.2.17\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An access-control system has been developed for the safety operation of the large helical device(LHD)at the National Institute for Fusion Science.The central part of the control system consists of a main computer,a manual-operation box and a sequencer-control system.The system monitors five turnstiles,eight shielding doors and other points of entry and directly supplies the interlock signals to the LHD control system.The sequencer-control system,which provides independent access control of each gate,is effective to control simultaneously all of the entry according to the status of the LHD and to permit the access of radiation workers belonging to a specific work group according to the situation of LHD plasma experiment.The safety management of LHD experiments has been performed without any serious troubles by this access control system including the interlock system since 1998.\",\"PeriodicalId\":7974,\"journal\":{\"name\":\"Annual Report of National Institute for Fusion Science\",\"volume\":\"23 1\",\"pages\":\"448\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-02-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annual Report of National Institute for Fusion Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12950/RSM2002.2.17\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual Report of National Institute for Fusion Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12950/RSM2002.2.17","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为保证核聚变科学研究所大型螺旋装置(LHD)的安全运行,研制了一套门禁控制系统。控制系统的中心部分由一台主计算机、一个手动操作箱和一个序列控制系统组成。该系统监控五个转门,八个屏蔽门和其他入口点,并直接向LHD控制系统提供联锁信号。序列控制系统提供了每个门的独立访问控制,可以有效地根据LHD的状态同时控制所有入口,并根据LHD等离子体实验的情况允许属于特定工作组的辐射工作人员进入。自1998年以来,采用该门禁系统(包括联锁系统)对LHD实验进行安全管理,没有遇到任何严重的问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Report of Operational Results of an Access Control System Developed for LHD Controlled Area
An access-control system has been developed for the safety operation of the large helical device(LHD)at the National Institute for Fusion Science.The central part of the control system consists of a main computer,a manual-operation box and a sequencer-control system.The system monitors five turnstiles,eight shielding doors and other points of entry and directly supplies the interlock signals to the LHD control system.The sequencer-control system,which provides independent access control of each gate,is effective to control simultaneously all of the entry according to the status of the LHD and to permit the access of radiation workers belonging to a specific work group according to the situation of LHD plasma experiment.The safety management of LHD experiments has been performed without any serious troubles by this access control system including the interlock system since 1998.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
ACT2: a High Heat Flux Test Facility using Electron Beam for Fusion Application Development of In Situ Visualization Tool for PIC Simulation A Kinetic Model of Magnetic Field Reconnection A New Algorithm for Differential-Algebraic Equations Based on HIDM Shielding effect on tritium water monitoring system based on CaF2 flow-cell detector
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1