{"title":"液相色谱法同时测定药物剂型阿普唑仑和美贝弗林含量的研究","authors":"Anup K Mamgain","doi":"10.29070/15/57490","DOIUrl":null,"url":null,"abstract":"A delicate, quick, exact and reproducible Isocratic, RP-LC strategy was created for assurance of Alprazolam and Mebeverine in pharmaceutical measurement frame. A Sunfire C18, 5 pm segment with portable stage containing methanol: cradle (0.02M KH2P04) (70:30). The stream rate was 1.0 ml/min and effluents were observed at 225 nm with help of PDA identifier. The maintenance time was 6.04 min. for ALP and 3.53 min. for MEB. The linearity was in the scope of 0.05-40 gg/ml for ALP and 0.2-40 pig/ml for MEB. The proposed strategy was approved regarding linearity, exactness, accuracy, specificity and strength. Because of straightforwardness, rate and exactness of technique, trust that the strategy will be helpful for routine quality control examination.","PeriodicalId":14911,"journal":{"name":"Journal of Advances and Scholarly Researches in Allied Education","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An Investigation on Liquid Chromatographic Technique for Simultaneous Measurement of Alprazolam and Mebeverine in Pharmaceutical Dose Form\",\"authors\":\"Anup K Mamgain\",\"doi\":\"10.29070/15/57490\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A delicate, quick, exact and reproducible Isocratic, RP-LC strategy was created for assurance of Alprazolam and Mebeverine in pharmaceutical measurement frame. A Sunfire C18, 5 pm segment with portable stage containing methanol: cradle (0.02M KH2P04) (70:30). The stream rate was 1.0 ml/min and effluents were observed at 225 nm with help of PDA identifier. The maintenance time was 6.04 min. for ALP and 3.53 min. for MEB. The linearity was in the scope of 0.05-40 gg/ml for ALP and 0.2-40 pig/ml for MEB. The proposed strategy was approved regarding linearity, exactness, accuracy, specificity and strength. Because of straightforwardness, rate and exactness of technique, trust that the strategy will be helpful for routine quality control examination.\",\"PeriodicalId\":14911,\"journal\":{\"name\":\"Journal of Advances and Scholarly Researches in Allied Education\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advances and Scholarly Researches in Allied Education\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29070/15/57490\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advances and Scholarly Researches in Allied Education","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29070/15/57490","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An Investigation on Liquid Chromatographic Technique for Simultaneous Measurement of Alprazolam and Mebeverine in Pharmaceutical Dose Form
A delicate, quick, exact and reproducible Isocratic, RP-LC strategy was created for assurance of Alprazolam and Mebeverine in pharmaceutical measurement frame. A Sunfire C18, 5 pm segment with portable stage containing methanol: cradle (0.02M KH2P04) (70:30). The stream rate was 1.0 ml/min and effluents were observed at 225 nm with help of PDA identifier. The maintenance time was 6.04 min. for ALP and 3.53 min. for MEB. The linearity was in the scope of 0.05-40 gg/ml for ALP and 0.2-40 pig/ml for MEB. The proposed strategy was approved regarding linearity, exactness, accuracy, specificity and strength. Because of straightforwardness, rate and exactness of technique, trust that the strategy will be helpful for routine quality control examination.