放射性废物容器的伽马辐射剂量率评估

IF 2.1 Q3 ENGINEERING, ENVIRONMENTAL Journal of Hazardous, Toxic, and Radioactive Waste Pub Date : 2023-01-01 DOI:10.25283/2587-9707-2023-2-35-40
A. Ksenofontov, D. Savin
{"title":"放射性废物容器的伽马辐射剂量率评估","authors":"A. Ksenofontov, D. Savin","doi":"10.25283/2587-9707-2023-2-35-40","DOIUrl":null,"url":null,"abstract":"Assessment of personnel exposure from various operations performed inside radioactive waste (RW) storage facilities is seen as an essential task under the safety assessment of such storage facilities. However, radiation scattered from the structures inside the premises of RW storage facilities is often not taken into account in the assessment of personnel exposure doses. Characteristics of the radiation field from RW containers have been calculated under a few studies. For example, the radiation fields were calculated based on some engineering approaches and the Monte Carlo method using specialized software. This paper focuses on the Monte Carlo calculations of the gamma radiation dose rate from a volumetric cylindrical source located in a RW storage facility. The study evaluates the contributions of scattered radiation from the walls, floor and ceiling of a storage premise to the absorbed dose also considering the case of a flooded floor. The paper compares the calculated radiation dose rates with those evaluated by integrating the source volume for axisymmetric geometries with no account taken of scattered radiation. The calculations show that depending on the distance from the source if no scattered radiation from all the wall, floor and ceiling structures of a storage facility is accounted for, the dose rate may be underestimated by up to two times.","PeriodicalId":15963,"journal":{"name":"Journal of Hazardous, Toxic, and Radioactive Waste","volume":"15 1","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of Gamma Radiation Dose Rate from a Container with Radioactive Waste\",\"authors\":\"A. Ksenofontov, D. Savin\",\"doi\":\"10.25283/2587-9707-2023-2-35-40\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Assessment of personnel exposure from various operations performed inside radioactive waste (RW) storage facilities is seen as an essential task under the safety assessment of such storage facilities. However, radiation scattered from the structures inside the premises of RW storage facilities is often not taken into account in the assessment of personnel exposure doses. Characteristics of the radiation field from RW containers have been calculated under a few studies. For example, the radiation fields were calculated based on some engineering approaches and the Monte Carlo method using specialized software. This paper focuses on the Monte Carlo calculations of the gamma radiation dose rate from a volumetric cylindrical source located in a RW storage facility. The study evaluates the contributions of scattered radiation from the walls, floor and ceiling of a storage premise to the absorbed dose also considering the case of a flooded floor. The paper compares the calculated radiation dose rates with those evaluated by integrating the source volume for axisymmetric geometries with no account taken of scattered radiation. The calculations show that depending on the distance from the source if no scattered radiation from all the wall, floor and ceiling structures of a storage facility is accounted for, the dose rate may be underestimated by up to two times.\",\"PeriodicalId\":15963,\"journal\":{\"name\":\"Journal of Hazardous, Toxic, and Radioactive Waste\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hazardous, Toxic, and Radioactive Waste\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25283/2587-9707-2023-2-35-40\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hazardous, Toxic, and Radioactive Waste","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25283/2587-9707-2023-2-35-40","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

在放射性废物贮存设施的安全评估中,对人员在贮存设施内进行的各种操作的暴露进行评估被视为一项重要任务。然而,在评估人员照射剂量时,往往不考虑从放射性废物储存设施房舍内的结构中散射出来的辐射。在一些研究中,计算了RW容器的辐射场特性。例如,利用专门的软件,根据一些工程方法和蒙特卡罗方法计算了辐射场。本文主要讨论了位于放射性核废料储存设施内的体积圆柱形源的伽马辐射剂量率的蒙特卡罗计算。本研究评估了储存库的墙壁、地板和天花板的散射辐射对吸收剂量的贡献,同时也考虑了地板被淹的情况。本文将计算的辐射剂量率与不考虑散射辐射的轴对称几何源体积积分计算的辐射剂量率进行了比较。计算表明,如果不考虑储存设施所有墙壁、地板和天花板结构的散射辐射,则剂量率可能被低估多达两倍,这取决于与源的距离。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of Gamma Radiation Dose Rate from a Container with Radioactive Waste
Assessment of personnel exposure from various operations performed inside radioactive waste (RW) storage facilities is seen as an essential task under the safety assessment of such storage facilities. However, radiation scattered from the structures inside the premises of RW storage facilities is often not taken into account in the assessment of personnel exposure doses. Characteristics of the radiation field from RW containers have been calculated under a few studies. For example, the radiation fields were calculated based on some engineering approaches and the Monte Carlo method using specialized software. This paper focuses on the Monte Carlo calculations of the gamma radiation dose rate from a volumetric cylindrical source located in a RW storage facility. The study evaluates the contributions of scattered radiation from the walls, floor and ceiling of a storage premise to the absorbed dose also considering the case of a flooded floor. The paper compares the calculated radiation dose rates with those evaluated by integrating the source volume for axisymmetric geometries with no account taken of scattered radiation. The calculations show that depending on the distance from the source if no scattered radiation from all the wall, floor and ceiling structures of a storage facility is accounted for, the dose rate may be underestimated by up to two times.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.40
自引率
7.40%
发文量
80
期刊最新文献
Naturally Occurring Radioactive Material Waste Management in the ASEAN Oil and Gas Industry: A Review A Planning-Support Tool for Spatial Suitability Assessment of Harvesting Sites for Stormwater Infrastructure Stress–Dilatancy and Critical-State Behavior of Geogrid-Reinforced Recycled Waste Materials NORM Waste Management in Vietnam’s Oil and Gas Industry: Lessons from Malaysia Gowanus Canal Superfund Site. VI: Rapid Field Screening Techniques to Verify Sediment Capping Blends
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1