肺超声在调整急性呼吸窘迫综合征患者初始机械通气设置中的应用

IF 0.2 Q4 RESPIRATORY SYSTEM Egyptian Journal of Chest Diseases and Tuberculosis Pub Date : 2023-01-01 DOI:10.4103/ecdt.ecdt_35_22
Menna-Allah Mohamed, Magdy Khalil, Haytham S. Diab, Ashraf El-Maraghy
{"title":"肺超声在调整急性呼吸窘迫综合征患者初始机械通气设置中的应用","authors":"Menna-Allah Mohamed, Magdy Khalil, Haytham S. Diab, Ashraf El-Maraghy","doi":"10.4103/ecdt.ecdt_35_22","DOIUrl":null,"url":null,"abstract":"Background Bedside lung ultrasound (US) is an essential tool in assessing lung aeration in severely ill patients. Aim The goal of this study was to determine the use of lung US in evaluating changes in lung aeration in dependent lung areas during positive end expiratory pressure (PEEP) titration in patients with acute respiratory distress syndrome (ARDS). Patients and methods A total of 52 mechanically ventilated patients with ARDS admitted in the ICU of Abbassia Chest Hospital were enrolled in this study. Transthoracic sonography was performed at the posterior axillary line on either side after 30 min of initial ventilator settings; recruitment at the end of expiration was sonographically assessed while changing PEEP. Arterial blood gases were performed before and after recruitment maneuver along with continuous monitoring of hemodynamics and oxygen saturation throughout the procedure. The procedure was terminated if the plateau pressure exceeded 30 cmH2O or if there was hemodynamic compromise. Results A total of 52 mechanically ventilated patients with ARDS were enrolled in the study. Overall, 80% had severe ARDS. Initial US assessments were done, and subpleural consolidation (C) was found in 18 patients, whereas exaggerated B lines (B) were found in 33 patients. After PEEP titration, under US guidance, 13 patients changed the US pattern from C to B and 22 patients changed from B to A (A-line pattern). These results correlated with improvement of PaO2/FiO2 ratio from 69.98 ± 27.93 to 86.21 ± 31.64 and increased compliance from 26.49 ± 8.63 to 28.73 ± 8.74. However, there was an increase in plateau pressure from 25.12 ± 3.88 to 27.98 ± 3.18, and also PaCO2 increased from 51.00 ± 16.05 to 58.52 ± 15.93. The mean arterial blood pressure decreased from 84.87 ± 7.91 to 81.60 ± 8.72. Conclusion US is an effective tool in achieving PEEP titration in mechanically ventilated patients with ARDS. US finding of aeration correlates well with improvement in oxygenation and compliance. However, the patients should be monitored for safe limits of pressures, hemodynamics, and PaCO2 level that may rise.","PeriodicalId":46359,"journal":{"name":"Egyptian Journal of Chest Diseases and Tuberculosis","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Utility of lung ultrasound in adjustment of the initial mechanical ventilation settings in patients with acute respiratory distress syndrome\",\"authors\":\"Menna-Allah Mohamed, Magdy Khalil, Haytham S. Diab, Ashraf El-Maraghy\",\"doi\":\"10.4103/ecdt.ecdt_35_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background Bedside lung ultrasound (US) is an essential tool in assessing lung aeration in severely ill patients. Aim The goal of this study was to determine the use of lung US in evaluating changes in lung aeration in dependent lung areas during positive end expiratory pressure (PEEP) titration in patients with acute respiratory distress syndrome (ARDS). Patients and methods A total of 52 mechanically ventilated patients with ARDS admitted in the ICU of Abbassia Chest Hospital were enrolled in this study. Transthoracic sonography was performed at the posterior axillary line on either side after 30 min of initial ventilator settings; recruitment at the end of expiration was sonographically assessed while changing PEEP. Arterial blood gases were performed before and after recruitment maneuver along with continuous monitoring of hemodynamics and oxygen saturation throughout the procedure. The procedure was terminated if the plateau pressure exceeded 30 cmH2O or if there was hemodynamic compromise. Results A total of 52 mechanically ventilated patients with ARDS were enrolled in the study. Overall, 80% had severe ARDS. Initial US assessments were done, and subpleural consolidation (C) was found in 18 patients, whereas exaggerated B lines (B) were found in 33 patients. After PEEP titration, under US guidance, 13 patients changed the US pattern from C to B and 22 patients changed from B to A (A-line pattern). These results correlated with improvement of PaO2/FiO2 ratio from 69.98 ± 27.93 to 86.21 ± 31.64 and increased compliance from 26.49 ± 8.63 to 28.73 ± 8.74. However, there was an increase in plateau pressure from 25.12 ± 3.88 to 27.98 ± 3.18, and also PaCO2 increased from 51.00 ± 16.05 to 58.52 ± 15.93. The mean arterial blood pressure decreased from 84.87 ± 7.91 to 81.60 ± 8.72. Conclusion US is an effective tool in achieving PEEP titration in mechanically ventilated patients with ARDS. US finding of aeration correlates well with improvement in oxygenation and compliance. However, the patients should be monitored for safe limits of pressures, hemodynamics, and PaCO2 level that may rise.\",\"PeriodicalId\":46359,\"journal\":{\"name\":\"Egyptian Journal of Chest Diseases and Tuberculosis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Egyptian Journal of Chest Diseases and Tuberculosis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ecdt.ecdt_35_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Journal of Chest Diseases and Tuberculosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ecdt.ecdt_35_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

摘要

床边肺超声(US)是评估重症患者肺通气的重要工具。目的本研究的目的是确定肺US在评估急性呼吸窘迫综合征(ARDS)患者呼气末正压(PEEP)滴定期间依赖肺区肺通气变化中的应用。患者与方法本研究选取了52例阿巴西亚胸科医院ICU收治的机械通气ARDS患者。在初始呼吸机设置30分钟后,在两侧的后腋窝线进行经胸超声检查;在改变PEEP的同时,超声评估呼气结束时的恢复情况。在手术前后进行动脉血气测量,并在整个手术过程中持续监测血流动力学和血氧饱和度。如果平台压超过30 cmH2O或存在血流动力学损害,则终止手术。结果共纳入52例机械通气ARDS患者。总的来说,80%的人患有严重的ARDS。进行了初步的US评估,18例患者发现胸膜下实变(C),而33例患者发现夸大的B线(B)。经PEEP滴定后,在US指导下,13例患者US模式由C变为B, 22例患者US模式由B变为A (A线模式)。结果表明,PaO2/FiO2比值从69.98±27.93提高到86.21±31.64,依从性从26.49±8.63提高到28.73±8.74。平台压由25.12±3.88上升至27.98±3.18,PaCO2由51.00±16.05上升至58.52±15.93。平均动脉血压由84.87±7.91降至81.60±8.72。结论US是ARDS机械通气患者实现PEEP滴定的有效工具。美国发现曝气与氧合和依从性的改善密切相关。然而,应监测患者血压、血流动力学和可能升高的PaCO2水平的安全限度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Utility of lung ultrasound in adjustment of the initial mechanical ventilation settings in patients with acute respiratory distress syndrome
Background Bedside lung ultrasound (US) is an essential tool in assessing lung aeration in severely ill patients. Aim The goal of this study was to determine the use of lung US in evaluating changes in lung aeration in dependent lung areas during positive end expiratory pressure (PEEP) titration in patients with acute respiratory distress syndrome (ARDS). Patients and methods A total of 52 mechanically ventilated patients with ARDS admitted in the ICU of Abbassia Chest Hospital were enrolled in this study. Transthoracic sonography was performed at the posterior axillary line on either side after 30 min of initial ventilator settings; recruitment at the end of expiration was sonographically assessed while changing PEEP. Arterial blood gases were performed before and after recruitment maneuver along with continuous monitoring of hemodynamics and oxygen saturation throughout the procedure. The procedure was terminated if the plateau pressure exceeded 30 cmH2O or if there was hemodynamic compromise. Results A total of 52 mechanically ventilated patients with ARDS were enrolled in the study. Overall, 80% had severe ARDS. Initial US assessments were done, and subpleural consolidation (C) was found in 18 patients, whereas exaggerated B lines (B) were found in 33 patients. After PEEP titration, under US guidance, 13 patients changed the US pattern from C to B and 22 patients changed from B to A (A-line pattern). These results correlated with improvement of PaO2/FiO2 ratio from 69.98 ± 27.93 to 86.21 ± 31.64 and increased compliance from 26.49 ± 8.63 to 28.73 ± 8.74. However, there was an increase in plateau pressure from 25.12 ± 3.88 to 27.98 ± 3.18, and also PaCO2 increased from 51.00 ± 16.05 to 58.52 ± 15.93. The mean arterial blood pressure decreased from 84.87 ± 7.91 to 81.60 ± 8.72. Conclusion US is an effective tool in achieving PEEP titration in mechanically ventilated patients with ARDS. US finding of aeration correlates well with improvement in oxygenation and compliance. However, the patients should be monitored for safe limits of pressures, hemodynamics, and PaCO2 level that may rise.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
46
审稿时长
22 weeks
期刊介绍: The journal will cover technical and clinical studies related to health, ethical and social issues in field of The Egyptian Journal of Chest Diseases and Tuberculosis aims to publish and inform readers and all chest physicians of the progress in medical research concerning all aspect of chest diseases. Publications include original articles review articles, editorials, case studies and reports which are relevant to chest diseases. The Journal also aims to highlight recent updates in chest medicine. . Articles with clinical interest and implications will be given preference.
期刊最新文献
Escalation to invasive mechanical ventilation in noninvasive ventilation failure: some insights about methodology Effect of physiotherapy and its frequency on the outcome of COVID-19 patients regarding acute care setting at isolation unit of Ain Shams University Role of interleukin-6 in coronavirus disease 2019 pneumonia: sensitive marker of inflammation, a predictor of ventilatory support and early marker of post-coronavirus disease lung fibrosis. A single center experience Diagnostic performance of transthoracic ultrasound in patients with pulmonary embolism Proportion and prognosis of ICU-admitted coronavirus disease 2019-infected patients in relation to all hospitalized cases in Abbasia Chest Hospital, Cairo
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1