{"title":"非正交轴系全站仪视轴标定后的校正方法","authors":"Peng Congcong, Wu Bin, Ma Gaoju, Kang Jiehu","doi":"10.1109/I2MTC50364.2021.9459788","DOIUrl":null,"url":null,"abstract":"The non-orthogonal shafting total station (N-total station) is designed for large-scale measurement field, and composed of two rotation axes and a sight axis. Each axis is defined by a direction vector and a fixed point. The dynamic pose of the sight axis is the key parameter to solve the space point coordinate. A correction method for the sight axis of the N-total station after calibration is proposed. There are six offset terms to be set as coefficients when the sight axis shifts. Based on the kinematic measurement model, a new sight axis can be reshaped with the solution of the coefficient obtained by the optimization method. The experimental results well verify that the calibration method is suitable for the N-total station.","PeriodicalId":6772,"journal":{"name":"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","volume":"51 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Correction Method for Sight Axis of Nonorthogonal Shafting Total Station after Calibration\",\"authors\":\"Peng Congcong, Wu Bin, Ma Gaoju, Kang Jiehu\",\"doi\":\"10.1109/I2MTC50364.2021.9459788\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The non-orthogonal shafting total station (N-total station) is designed for large-scale measurement field, and composed of two rotation axes and a sight axis. Each axis is defined by a direction vector and a fixed point. The dynamic pose of the sight axis is the key parameter to solve the space point coordinate. A correction method for the sight axis of the N-total station after calibration is proposed. There are six offset terms to be set as coefficients when the sight axis shifts. Based on the kinematic measurement model, a new sight axis can be reshaped with the solution of the coefficient obtained by the optimization method. The experimental results well verify that the calibration method is suitable for the N-total station.\",\"PeriodicalId\":6772,\"journal\":{\"name\":\"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"volume\":\"51 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2MTC50364.2021.9459788\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2MTC50364.2021.9459788","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Correction Method for Sight Axis of Nonorthogonal Shafting Total Station after Calibration
The non-orthogonal shafting total station (N-total station) is designed for large-scale measurement field, and composed of two rotation axes and a sight axis. Each axis is defined by a direction vector and a fixed point. The dynamic pose of the sight axis is the key parameter to solve the space point coordinate. A correction method for the sight axis of the N-total station after calibration is proposed. There are six offset terms to be set as coefficients when the sight axis shifts. Based on the kinematic measurement model, a new sight axis can be reshaped with the solution of the coefficient obtained by the optimization method. The experimental results well verify that the calibration method is suitable for the N-total station.