高光谱成像仪等效焦平面组装模块的设计

高志良 Gao Zhi-liang
{"title":"高光谱成像仪等效焦平面组装模块的设计","authors":"高志良 Gao Zhi-liang","doi":"10.3788/CO.20140704.0644","DOIUrl":null,"url":null,"abstract":"When assembling CCD of hyperspectral imager,20 μm focal depth should be satisfied in longitudinal direction,and alignment in spectral and spacial direction should also be achieved. An equivalent focal plane assembling module is designed to avoid frequent installation of expensive CCD during measurements.The equivalent module is precisely manufactured according to measured dimensions of CCD module. It also provides simulated spectral image that could be observed by microscope. By measuring distance between real and simulated spectral image,spacer's reshape value is calculated,and spectral image is aligned to CCD laterally. Experiment shows that the whole spectral image's defocusing value is in focal depth in the presence of tool microscope measuring error,spacer reparation error and interchangeability error. MTF is higher than 0. 3after 3 iterations in experiment,which shows an improvement on efficiency and safety.","PeriodicalId":10133,"journal":{"name":"Chinese Journal of Optics and Applied Optics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Design of hyperspectral imager equivalent focal plane assembling module\",\"authors\":\"高志良 Gao Zhi-liang\",\"doi\":\"10.3788/CO.20140704.0644\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When assembling CCD of hyperspectral imager,20 μm focal depth should be satisfied in longitudinal direction,and alignment in spectral and spacial direction should also be achieved. An equivalent focal plane assembling module is designed to avoid frequent installation of expensive CCD during measurements.The equivalent module is precisely manufactured according to measured dimensions of CCD module. It also provides simulated spectral image that could be observed by microscope. By measuring distance between real and simulated spectral image,spacer's reshape value is calculated,and spectral image is aligned to CCD laterally. Experiment shows that the whole spectral image's defocusing value is in focal depth in the presence of tool microscope measuring error,spacer reparation error and interchangeability error. MTF is higher than 0. 3after 3 iterations in experiment,which shows an improvement on efficiency and safety.\",\"PeriodicalId\":10133,\"journal\":{\"name\":\"Chinese Journal of Optics and Applied Optics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chinese Journal of Optics and Applied Optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3788/CO.20140704.0644\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Optics and Applied Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3788/CO.20140704.0644","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

安装高光谱成像仪CCD时,在纵向上要满足20 μm的焦深,在光谱方向和空间方向上也要实现对准。为了避免在测量过程中频繁安装昂贵的CCD,设计了等效焦平面组装模块。根据CCD模块的测量尺寸,精确制作等效模块。它还提供了可以用显微镜观察的模拟光谱图像。通过测量真实光谱图像与模拟光谱图像之间的距离,计算间隔器的重塑值,并将光谱图像横向对准CCD。实验表明,在存在工具显微镜测量误差、间隔片修复误差和互换性误差的情况下,整个光谱图像的离焦值处于焦深。MTF大于0。实验经过3次迭代,在效率和安全性上均有提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design of hyperspectral imager equivalent focal plane assembling module
When assembling CCD of hyperspectral imager,20 μm focal depth should be satisfied in longitudinal direction,and alignment in spectral and spacial direction should also be achieved. An equivalent focal plane assembling module is designed to avoid frequent installation of expensive CCD during measurements.The equivalent module is precisely manufactured according to measured dimensions of CCD module. It also provides simulated spectral image that could be observed by microscope. By measuring distance between real and simulated spectral image,spacer's reshape value is calculated,and spectral image is aligned to CCD laterally. Experiment shows that the whole spectral image's defocusing value is in focal depth in the presence of tool microscope measuring error,spacer reparation error and interchangeability error. MTF is higher than 0. 3after 3 iterations in experiment,which shows an improvement on efficiency and safety.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Validation method of single-channel optical system design of CO2detector SiO 2 包覆对ZnS纳米材料发光的增强机制 热蒸发与离子束溅射制备LaF 3 薄膜的光学特性 TiO 2 纳米线阵列干涉传感器 化学气相沉积法制备Zn 2 GeO 4 纳米线及其发光性质的研究
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1