高压高温实验室测试用高压穿透器的设计

J. Aakervik, G. Berg, S. Hvidsten
{"title":"高压高温实验室测试用高压穿透器的设计","authors":"J. Aakervik, G. Berg, S. Hvidsten","doi":"10.1109/CEIDP.2011.6232648","DOIUrl":null,"url":null,"abstract":"High voltage apparatus and reliable power supply are of vital importance for subsea processing. The purpose of this work has been to develop a small high voltage penetrator for use with high pressure vessels in the laboratory. Such equipment can facilitate high voltage and current testing of models and materials at relevant subsea conditions. It is shown that the penetrator can withstand a hydrostatic differential pressure of 500 bars and 90°C for more than 6 months. The breakdown voltage of the penetrator is only limited by the model cable used in the design, making it attractive to use high voltage class cables. Sensitive partial discharge measurements of pressurized test objects can be implemented by using adapted oil-filled terminations.","PeriodicalId":6317,"journal":{"name":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"3 1","pages":"267-270"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Design of a high voltage penetrator for high pressure and temperature laboratory testing\",\"authors\":\"J. Aakervik, G. Berg, S. Hvidsten\",\"doi\":\"10.1109/CEIDP.2011.6232648\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High voltage apparatus and reliable power supply are of vital importance for subsea processing. The purpose of this work has been to develop a small high voltage penetrator for use with high pressure vessels in the laboratory. Such equipment can facilitate high voltage and current testing of models and materials at relevant subsea conditions. It is shown that the penetrator can withstand a hydrostatic differential pressure of 500 bars and 90°C for more than 6 months. The breakdown voltage of the penetrator is only limited by the model cable used in the design, making it attractive to use high voltage class cables. Sensitive partial discharge measurements of pressurized test objects can be implemented by using adapted oil-filled terminations.\",\"PeriodicalId\":6317,\"journal\":{\"name\":\"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"3 1\",\"pages\":\"267-270\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2011.6232648\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2011.6232648","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

高压设备和可靠的电源是海底处理的关键。这项工作的目的是开发一种用于实验室高压容器的小型高压穿透器。这种设备可以方便地在相关海底条件下对模型和材料进行高压和电流测试。结果表明,该穿甲弹可承受90℃、500 bar的静水压差6个月以上。穿透器的击穿电压仅受设计中使用的型号电缆的限制,因此使用高压级电缆具有吸引力。通过使用合适的充油终端,可以实现对受压试验对象的敏感局部放电测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design of a high voltage penetrator for high pressure and temperature laboratory testing
High voltage apparatus and reliable power supply are of vital importance for subsea processing. The purpose of this work has been to develop a small high voltage penetrator for use with high pressure vessels in the laboratory. Such equipment can facilitate high voltage and current testing of models and materials at relevant subsea conditions. It is shown that the penetrator can withstand a hydrostatic differential pressure of 500 bars and 90°C for more than 6 months. The breakdown voltage of the penetrator is only limited by the model cable used in the design, making it attractive to use high voltage class cables. Sensitive partial discharge measurements of pressurized test objects can be implemented by using adapted oil-filled terminations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Influence of A.C. electric field on plant growth Optimum D.C. electric field strength for growth acceleration of thale cress Feasibility study on the detection of corrosion of a cable metal shield using terahertz imaging Comparison of the effects of nanofiller materials on the dielectric properties of epoxy nanocomposites Diagnosis of cable aging by broadband impedance spectroscopy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1