{"title":"坦吉尔不同地点空气质素参数的评估","authors":"M. Rehnuma, AA Riad, RI Shakur","doi":"10.3329/jesnr.v13i1-2.60699","DOIUrl":null,"url":null,"abstract":"The study was conducted to investigate the concentration of PM2.5, PM10, CH4, CO2, CO, SO2 in the air of Tangail Sadar Upazila, Tangail. In the study area air quality data has been collected from eight sampling stations namely MBSTU campus, Baby stand, Nirala more, New bus stand, Rabna bypass, College gate, Old bus stand, Nogor jalfoi during dry season. The air quality data collected by using Aeroqual S 500 series. The concentrations of PM2.5, PM10, CH4, CO2, CO, SO2 found in air were ranged from 0.03-0.06, 0.04-0.10, 12.3-36, 919-1238.2, 0.00- 2.61, 0.00-0.48 mg/m3, respectively. The concentration of PM2.5, PM10, CO, SO2 that have been found were higher than Bangladesh standard and WHO guideline. Their sources could be the motor vehicles, road dust, coal burning, road construction, open dumping of solid waste in Tangail Sadar Upazila. Appropriate engine design control strategies and maintenance services should be introduced for reducing emission. Efficient solid waste management system should be introduced to control emission from construction sources. \nEnviron. Sci. & Natural Resources, 13(1&2): 118-122, 2020","PeriodicalId":15768,"journal":{"name":"Journal of Environmental Science and Natural Resources","volume":"19 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of Air Quality Parameters at Different Locations of Tangail Sadar Upazila, Tangail\",\"authors\":\"M. Rehnuma, AA Riad, RI Shakur\",\"doi\":\"10.3329/jesnr.v13i1-2.60699\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The study was conducted to investigate the concentration of PM2.5, PM10, CH4, CO2, CO, SO2 in the air of Tangail Sadar Upazila, Tangail. In the study area air quality data has been collected from eight sampling stations namely MBSTU campus, Baby stand, Nirala more, New bus stand, Rabna bypass, College gate, Old bus stand, Nogor jalfoi during dry season. The air quality data collected by using Aeroqual S 500 series. The concentrations of PM2.5, PM10, CH4, CO2, CO, SO2 found in air were ranged from 0.03-0.06, 0.04-0.10, 12.3-36, 919-1238.2, 0.00- 2.61, 0.00-0.48 mg/m3, respectively. The concentration of PM2.5, PM10, CO, SO2 that have been found were higher than Bangladesh standard and WHO guideline. Their sources could be the motor vehicles, road dust, coal burning, road construction, open dumping of solid waste in Tangail Sadar Upazila. Appropriate engine design control strategies and maintenance services should be introduced for reducing emission. Efficient solid waste management system should be introduced to control emission from construction sources. \\nEnviron. Sci. & Natural Resources, 13(1&2): 118-122, 2020\",\"PeriodicalId\":15768,\"journal\":{\"name\":\"Journal of Environmental Science and Natural Resources\",\"volume\":\"19 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Environmental Science and Natural Resources\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3329/jesnr.v13i1-2.60699\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Science and Natural Resources","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3329/jesnr.v13i1-2.60699","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在调查坦吉尔市萨达尔乌帕齐拉市空气中PM2.5、PM10、CH4、CO2、CO、SO2的浓度。在研究区域,空气质量数据从8个采样站收集,即MBSTU校园,Baby stand, Nirala more,新公交站,Rabna旁路,学院大门,旧公交站,Nogor jalfoi在旱季。使用Aeroqual s500系列收集的空气质量数据。PM2.5、PM10、CH4、CO2、CO、SO2的浓度范围分别为0.03 ~ 0.06、0.04 ~ 0.10、12.3 ~ 36、919 ~ 1238.2、0.00 ~ 2.61、0.00 ~ 0.48 mg/m3。已发现的PM2.5、PM10、CO、SO2浓度均高于孟加拉国标准和世界卫生组织指导标准。它们的来源可能是机动车、道路灰尘、燃煤、道路建设、露天倾倒固体废物。应引入适当的发动机设计、控制策略和维修服务,以减少排放。应引入有效的固体废物管理系统,以控制建筑污染源的排放。环绕。科学。与自然资源,13(1&2):118-122,2020
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of Air Quality Parameters at Different Locations of Tangail Sadar Upazila, Tangail
The study was conducted to investigate the concentration of PM2.5, PM10, CH4, CO2, CO, SO2 in the air of Tangail Sadar Upazila, Tangail. In the study area air quality data has been collected from eight sampling stations namely MBSTU campus, Baby stand, Nirala more, New bus stand, Rabna bypass, College gate, Old bus stand, Nogor jalfoi during dry season. The air quality data collected by using Aeroqual S 500 series. The concentrations of PM2.5, PM10, CH4, CO2, CO, SO2 found in air were ranged from 0.03-0.06, 0.04-0.10, 12.3-36, 919-1238.2, 0.00- 2.61, 0.00-0.48 mg/m3, respectively. The concentration of PM2.5, PM10, CO, SO2 that have been found were higher than Bangladesh standard and WHO guideline. Their sources could be the motor vehicles, road dust, coal burning, road construction, open dumping of solid waste in Tangail Sadar Upazila. Appropriate engine design control strategies and maintenance services should be introduced for reducing emission. Efficient solid waste management system should be introduced to control emission from construction sources. Environ. Sci. & Natural Resources, 13(1&2): 118-122, 2020
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessment of Noise Exposure Indices at Kanchijhuli and Townhall Moor in Mymensingh City Assessment of Air Quality Parameters at Different Locations of Tangail Sadar Upazila, Tangail Screening of Some Botanicals for Eco-friendly Control of Cucurbit Fruit Fly (Bactrocera cucurbitae) Infestation in Experimental Cucumber Field Sanitation Pattern and its Impact on Child in Relation to their Diarrheal Disease of two Upazilla under Satkhira District Monitoring Long-Term Wheat Cultivation and Climatic Drivers for Land Use Change: A Case Study Using Remote Sensing at Thakurgaon Sadar in Bangladesh
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1