基于等效输入扰动法的隔离型小型混合电力系统负荷频率控制

Chunsheng Wang, Jiamin Li, Yukun Hu, Xin Zhang, L. Varga
{"title":"基于等效输入扰动法的隔离型小型混合电力系统负荷频率控制","authors":"Chunsheng Wang, Jiamin Li, Yukun Hu, Xin Zhang, L. Varga","doi":"10.12783/dteees/iceee2019/31785","DOIUrl":null,"url":null,"abstract":"In any isolated small power system employing a mix of renewable energy (RE) technology and legacy technology, frequency deviation is inevitable due to RE fluctuations and load demand variations. Therefore, an appropriate frequency control scheme is essential. This paper presents an Equivalent-Input-Disturbance (EID) control for load frequency control of isolated small hybrid renewable energy power system. EID method is applied to regulate the output power of the diesel generator and electric vehicle (EV) to maintain the power balance and ultimately maintain the frequency within normal range. Simulation studies show that this strategy has higher flexibility and control performance than the traditional PI method.","PeriodicalId":11324,"journal":{"name":"DEStech Transactions on Environment, Energy and Earth Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Load Frequency Control Based on Equivalent-input-disturbance Method for Isolated Small Hybrid Power System\",\"authors\":\"Chunsheng Wang, Jiamin Li, Yukun Hu, Xin Zhang, L. Varga\",\"doi\":\"10.12783/dteees/iceee2019/31785\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In any isolated small power system employing a mix of renewable energy (RE) technology and legacy technology, frequency deviation is inevitable due to RE fluctuations and load demand variations. Therefore, an appropriate frequency control scheme is essential. This paper presents an Equivalent-Input-Disturbance (EID) control for load frequency control of isolated small hybrid renewable energy power system. EID method is applied to regulate the output power of the diesel generator and electric vehicle (EV) to maintain the power balance and ultimately maintain the frequency within normal range. Simulation studies show that this strategy has higher flexibility and control performance than the traditional PI method.\",\"PeriodicalId\":11324,\"journal\":{\"name\":\"DEStech Transactions on Environment, Energy and Earth Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"DEStech Transactions on Environment, Energy and Earth Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12783/dteees/iceee2019/31785\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"DEStech Transactions on Environment, Energy and Earth Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12783/dteees/iceee2019/31785","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在任何采用可再生能源技术和传统技术混合的孤立小型电力系统中,由于可再生能源的波动和负载需求的变化,频率偏差是不可避免的。因此,适当的频率控制方案是必不可少的。提出了一种适用于隔离型小型混合可再生能源电力系统负荷频率控制的等效输入扰动控制方法。采用EID方法调节柴油发电机和电动汽车的输出功率,保持功率平衡,最终使频率保持在正常范围内。仿真研究表明,该策略比传统的PI方法具有更高的灵活性和控制性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Load Frequency Control Based on Equivalent-input-disturbance Method for Isolated Small Hybrid Power System
In any isolated small power system employing a mix of renewable energy (RE) technology and legacy technology, frequency deviation is inevitable due to RE fluctuations and load demand variations. Therefore, an appropriate frequency control scheme is essential. This paper presents an Equivalent-Input-Disturbance (EID) control for load frequency control of isolated small hybrid renewable energy power system. EID method is applied to regulate the output power of the diesel generator and electric vehicle (EV) to maintain the power balance and ultimately maintain the frequency within normal range. Simulation studies show that this strategy has higher flexibility and control performance than the traditional PI method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Research on Environmental Performance Evaluation of Petrochemical Enterprises Based on Balanced Scorecard-Entropy Method Measurement and Numerical Simulation Analysis of Smoke Flow Field after Dust Collector Modification Research on Collaborative Filtering Recommendation Algorithm Based on Mahout Preparation of Ultrafine -Al2O3 Powder from Fly Ash by Ammonium Sulfate Roasting Technology Design of Dual Mode Power Supply Distribution Circuit with Detection and Control Functions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1