{"title":"越南和平水库活动断层分割与地震危险性","authors":"P. T. Trinh, Hoàng Quang Vinh, N. Hương, N. Liem","doi":"10.2478/s13533-012-0128-5","DOIUrl":null,"url":null,"abstract":"Based on remote sensing, geological data, geomorphologic analysis, and field observations, we determine the fault system which is a potential source of earthquakes in Hoa-Binh reservoir. It is the sub-meridian fault system composed of fault segments located in the central part of the eastern and western flanks of the Quaternary Hoa-Binh Graben: the Hoa-Binh 1 fault is east-dipping (75–80°), N-S trending, 4 km long, situated in the west of the Hoa-Binh Graben, and the Hoa-Binh 2 is a west-dipping (75–80°), N-S trending; 8.4 km long fault, situated in the east of the Hoa-Binh Graben. The slip rate of normal fault in Hoa-Binh hydropower dam was estimated at 0.3–1.1 mm/yr. The Maximum Credible Earthquake (MCE) and Peak Ground Acceleration (PGA) in the Hoa-Binh hydropower dam have been assessed. The estimated MCE of HB.1 and HB.2 is 5.6 and 6.1 respectively, and the maximum PGA at Hoa-Binh dam is 0.30 g and 0.40 g, respectively. The assessment of seismic hazard in Hoa-Binh reservoir is a typical example of seismic hazards of a large dam constructed in an area of low seismicity and lack of law of seismic attenuation.","PeriodicalId":49092,"journal":{"name":"Central European Journal of Geosciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Active fault segmentation and seismic hazard in Hoa-Binh reservoir, Vietnam\",\"authors\":\"P. T. Trinh, Hoàng Quang Vinh, N. Hương, N. Liem\",\"doi\":\"10.2478/s13533-012-0128-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Based on remote sensing, geological data, geomorphologic analysis, and field observations, we determine the fault system which is a potential source of earthquakes in Hoa-Binh reservoir. It is the sub-meridian fault system composed of fault segments located in the central part of the eastern and western flanks of the Quaternary Hoa-Binh Graben: the Hoa-Binh 1 fault is east-dipping (75–80°), N-S trending, 4 km long, situated in the west of the Hoa-Binh Graben, and the Hoa-Binh 2 is a west-dipping (75–80°), N-S trending; 8.4 km long fault, situated in the east of the Hoa-Binh Graben. The slip rate of normal fault in Hoa-Binh hydropower dam was estimated at 0.3–1.1 mm/yr. The Maximum Credible Earthquake (MCE) and Peak Ground Acceleration (PGA) in the Hoa-Binh hydropower dam have been assessed. The estimated MCE of HB.1 and HB.2 is 5.6 and 6.1 respectively, and the maximum PGA at Hoa-Binh dam is 0.30 g and 0.40 g, respectively. The assessment of seismic hazard in Hoa-Binh reservoir is a typical example of seismic hazards of a large dam constructed in an area of low seismicity and lack of law of seismic attenuation.\",\"PeriodicalId\":49092,\"journal\":{\"name\":\"Central European Journal of Geosciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Central European Journal of Geosciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/s13533-012-0128-5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Central European Journal of Geosciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/s13533-012-0128-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Active fault segmentation and seismic hazard in Hoa-Binh reservoir, Vietnam
Based on remote sensing, geological data, geomorphologic analysis, and field observations, we determine the fault system which is a potential source of earthquakes in Hoa-Binh reservoir. It is the sub-meridian fault system composed of fault segments located in the central part of the eastern and western flanks of the Quaternary Hoa-Binh Graben: the Hoa-Binh 1 fault is east-dipping (75–80°), N-S trending, 4 km long, situated in the west of the Hoa-Binh Graben, and the Hoa-Binh 2 is a west-dipping (75–80°), N-S trending; 8.4 km long fault, situated in the east of the Hoa-Binh Graben. The slip rate of normal fault in Hoa-Binh hydropower dam was estimated at 0.3–1.1 mm/yr. The Maximum Credible Earthquake (MCE) and Peak Ground Acceleration (PGA) in the Hoa-Binh hydropower dam have been assessed. The estimated MCE of HB.1 and HB.2 is 5.6 and 6.1 respectively, and the maximum PGA at Hoa-Binh dam is 0.30 g and 0.40 g, respectively. The assessment of seismic hazard in Hoa-Binh reservoir is a typical example of seismic hazards of a large dam constructed in an area of low seismicity and lack of law of seismic attenuation.