{"title":"人体脊髓3T单体素¹H-MR光谱-初步结果","authors":"Wawrzyniak P, H. A., Heinze S, Bobek-Billewicz B","doi":"10.26420/austinjmedoncol.2021.1069","DOIUrl":null,"url":null,"abstract":"Purpose: ¹H-Magnetic Resonance Spectroscopy is a non-invasive technique that provides information on tissue metabolism and biochemistry. Because of technical difficulties, this method is rarely used in the spinal cord examination. The main goal of this study was to develop a routine protocol for MRS of intramedullary lesions. Material and methods: ¹H-MRS protocol was set on a group of healthy volunteers. 48 spectra were acquired in total. 30 of them were acquired in cervical spinal cord and the remaining (18 spectra) were acquired in the thoracic spinal cord. Results: In ¹H-MRS of the spinal cord one of the most important problem is small voxel size. Mean voxel size in this study was 7x9x29 mm - what is much smaller than in the brain examinations finally, almost 60% of spectra were of acceptable quality in volunteer examinations, what enabled the following patients’ examinations. Conclusions: Challenges of spinal cord spectroscopy were discussed and the ability of providing additional diagnostic information was proved.","PeriodicalId":8626,"journal":{"name":"Austin journal of medical oncology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Single Voxel ¹H-MR Spectroscopy in the Human Spinal Cord at 3T -Preliminary Results\",\"authors\":\"Wawrzyniak P, H. A., Heinze S, Bobek-Billewicz B\",\"doi\":\"10.26420/austinjmedoncol.2021.1069\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: ¹H-Magnetic Resonance Spectroscopy is a non-invasive technique that provides information on tissue metabolism and biochemistry. Because of technical difficulties, this method is rarely used in the spinal cord examination. The main goal of this study was to develop a routine protocol for MRS of intramedullary lesions. Material and methods: ¹H-MRS protocol was set on a group of healthy volunteers. 48 spectra were acquired in total. 30 of them were acquired in cervical spinal cord and the remaining (18 spectra) were acquired in the thoracic spinal cord. Results: In ¹H-MRS of the spinal cord one of the most important problem is small voxel size. Mean voxel size in this study was 7x9x29 mm - what is much smaller than in the brain examinations finally, almost 60% of spectra were of acceptable quality in volunteer examinations, what enabled the following patients’ examinations. Conclusions: Challenges of spinal cord spectroscopy were discussed and the ability of providing additional diagnostic information was proved.\",\"PeriodicalId\":8626,\"journal\":{\"name\":\"Austin journal of medical oncology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Austin journal of medical oncology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26420/austinjmedoncol.2021.1069\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Austin journal of medical oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26420/austinjmedoncol.2021.1069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的:¹h -磁共振波谱是一种非侵入性技术,可提供组织代谢和生物化学信息。由于技术上的困难,这种方法很少用于脊髓检查。本研究的主要目的是制定髓内病变的MRS常规方案。材料与方法:1健康志愿者H-MRS方案。共获得48个光谱。其中30个谱分布于颈脊髓,其余18个谱分布于胸脊髓。结果:在脊髓的H-MRS中,最重要的问题之一是体素小。本研究的平均体素大小为7x9x29mm,比脑部检查中的体素小得多。最后,在志愿者检查中,几乎60%的光谱质量可接受,这使得后续患者的检查成为可能。结论:讨论了脊髓光谱学的挑战,并证明了提供额外诊断信息的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Single Voxel ¹H-MR Spectroscopy in the Human Spinal Cord at 3T -Preliminary Results
Purpose: ¹H-Magnetic Resonance Spectroscopy is a non-invasive technique that provides information on tissue metabolism and biochemistry. Because of technical difficulties, this method is rarely used in the spinal cord examination. The main goal of this study was to develop a routine protocol for MRS of intramedullary lesions. Material and methods: ¹H-MRS protocol was set on a group of healthy volunteers. 48 spectra were acquired in total. 30 of them were acquired in cervical spinal cord and the remaining (18 spectra) were acquired in the thoracic spinal cord. Results: In ¹H-MRS of the spinal cord one of the most important problem is small voxel size. Mean voxel size in this study was 7x9x29 mm - what is much smaller than in the brain examinations finally, almost 60% of spectra were of acceptable quality in volunteer examinations, what enabled the following patients’ examinations. Conclusions: Challenges of spinal cord spectroscopy were discussed and the ability of providing additional diagnostic information was proved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Innovative Wound Dressing Coated with Drug-Loaded Adipose Mesenchymal Stem Cells to Promote Wound Healing in Diabetes Application of Deep Learning LSTM and ARIMA Models in Time Series Forecasting: A Methods Case Study analyzing Canadian and Swedish Indoor Air Pollution Data Low-Dose and Short-Course Dexamethasone Treatment as a New Therapy against the Post-Embolization Syndrome after Transcatheter Arterial Chemoembolization in Primary Liver Cancer: A Retrospective Case-Control Study Trastuzumab Induced Thrombocytopenia in Early Breast Cancer: Case Report and Review of Literature Single Voxel ¹H-MR Spectroscopy in the Human Spinal Cord at 3T -Preliminary Results
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1