{"title":"3,3 ' -二氯联苯胺(DCB)在两个化工厂的暴露评估","authors":"M. London, J. Boiano, Steven A. Lee","doi":"10.1080/08828032.1989.10390362","DOIUrl":null,"url":null,"abstract":"Abstract 3,3′-Dichlorobenzidine (DCB), an analogue of benzidine, has been an Occupational Safety and Health Administration (OSHA)-regulated carcinogen since 1974. This article presents a limited case study evaluating worker exposure to DCB at two pigment manufacturing plants. In each plant, exposure to DCB was estimated by personal breathing-zone (PBZ) and general area (GA) air samples, by skin patch and surface wipe samples, and by analysis of urine collected before and after the DCB-charging operation. Plant A performs the DCB-charging operation in a dedicated 12-ft × 10-ft enclosed room. Two workers perform the operation, each wearing full protective clothing and an air-supplied hood. After decontaminating the work area with a sodium hypochlorite bleach solution, the workers enter a “dirty” change room to undress, and then shower and change into clean work clothes in a “clean” change room. The levels of DCB found averaged 0.45 μg/m3, PBZ; 0.18 μg/m3, GA; and 0.04 μg/cm2, skin. Detectable levels of urin...","PeriodicalId":8049,"journal":{"name":"Applied Industrial Hygiene","volume":"48 1","pages":"101-104"},"PeriodicalIF":0.0000,"publicationDate":"1989-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Exposure Assessment of 3,3′-Dichlorobenzidine (DCB) at Two Chemical Plants\",\"authors\":\"M. London, J. Boiano, Steven A. Lee\",\"doi\":\"10.1080/08828032.1989.10390362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract 3,3′-Dichlorobenzidine (DCB), an analogue of benzidine, has been an Occupational Safety and Health Administration (OSHA)-regulated carcinogen since 1974. This article presents a limited case study evaluating worker exposure to DCB at two pigment manufacturing plants. In each plant, exposure to DCB was estimated by personal breathing-zone (PBZ) and general area (GA) air samples, by skin patch and surface wipe samples, and by analysis of urine collected before and after the DCB-charging operation. Plant A performs the DCB-charging operation in a dedicated 12-ft × 10-ft enclosed room. Two workers perform the operation, each wearing full protective clothing and an air-supplied hood. After decontaminating the work area with a sodium hypochlorite bleach solution, the workers enter a “dirty” change room to undress, and then shower and change into clean work clothes in a “clean” change room. The levels of DCB found averaged 0.45 μg/m3, PBZ; 0.18 μg/m3, GA; and 0.04 μg/cm2, skin. Detectable levels of urin...\",\"PeriodicalId\":8049,\"journal\":{\"name\":\"Applied Industrial Hygiene\",\"volume\":\"48 1\",\"pages\":\"101-104\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Industrial Hygiene\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/08828032.1989.10390362\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Industrial Hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08828032.1989.10390362","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Exposure Assessment of 3,3′-Dichlorobenzidine (DCB) at Two Chemical Plants
Abstract 3,3′-Dichlorobenzidine (DCB), an analogue of benzidine, has been an Occupational Safety and Health Administration (OSHA)-regulated carcinogen since 1974. This article presents a limited case study evaluating worker exposure to DCB at two pigment manufacturing plants. In each plant, exposure to DCB was estimated by personal breathing-zone (PBZ) and general area (GA) air samples, by skin patch and surface wipe samples, and by analysis of urine collected before and after the DCB-charging operation. Plant A performs the DCB-charging operation in a dedicated 12-ft × 10-ft enclosed room. Two workers perform the operation, each wearing full protective clothing and an air-supplied hood. After decontaminating the work area with a sodium hypochlorite bleach solution, the workers enter a “dirty” change room to undress, and then shower and change into clean work clothes in a “clean” change room. The levels of DCB found averaged 0.45 μg/m3, PBZ; 0.18 μg/m3, GA; and 0.04 μg/cm2, skin. Detectable levels of urin...