Pawan Deep Singh, Lalit Dutta, Onkar Singh, Sanjeev Mishra, A. Khuroo, T. Monif, A. Ahmed, Nirmala Yadav
{"title":"选择性、灵敏、快速液相色谱-串联质谱法测定人血浆中愈创甘油醚的含量","authors":"Pawan Deep Singh, Lalit Dutta, Onkar Singh, Sanjeev Mishra, A. Khuroo, T. Monif, A. Ahmed, Nirmala Yadav","doi":"10.3109/10601333.2010.513387","DOIUrl":null,"url":null,"abstract":"A simple, sensitive, selective, and rapid liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed and validated for quantitation of guaifenesin in human plasma using guaifenesin-d3 as internal standard (IS). Following solid phase extraction, the analyte was chromatographed using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in multiple reaction-monitoring (MRM) mode (positive ion mode). The limit of quantitation for this method was 8 ng/mL and the linear dynamic range was 8–2200 ng/mL.","PeriodicalId":10446,"journal":{"name":"Clinical Research and Regulatory Affairs","volume":"52 1","pages":"121 - 127"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Selective, sensitive, and rapid liquid chromatography-tandem mass spectrometry method for determination of Guaifenesin in human plasma\",\"authors\":\"Pawan Deep Singh, Lalit Dutta, Onkar Singh, Sanjeev Mishra, A. Khuroo, T. Monif, A. Ahmed, Nirmala Yadav\",\"doi\":\"10.3109/10601333.2010.513387\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple, sensitive, selective, and rapid liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed and validated for quantitation of guaifenesin in human plasma using guaifenesin-d3 as internal standard (IS). Following solid phase extraction, the analyte was chromatographed using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in multiple reaction-monitoring (MRM) mode (positive ion mode). The limit of quantitation for this method was 8 ng/mL and the linear dynamic range was 8–2200 ng/mL.\",\"PeriodicalId\":10446,\"journal\":{\"name\":\"Clinical Research and Regulatory Affairs\",\"volume\":\"52 1\",\"pages\":\"121 - 127\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Research and Regulatory Affairs\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10601333.2010.513387\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Research and Regulatory Affairs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10601333.2010.513387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Selective, sensitive, and rapid liquid chromatography-tandem mass spectrometry method for determination of Guaifenesin in human plasma
A simple, sensitive, selective, and rapid liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed and validated for quantitation of guaifenesin in human plasma using guaifenesin-d3 as internal standard (IS). Following solid phase extraction, the analyte was chromatographed using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in multiple reaction-monitoring (MRM) mode (positive ion mode). The limit of quantitation for this method was 8 ng/mL and the linear dynamic range was 8–2200 ng/mL.