温度和压力对风速计响应特性的影响

IF 0.8 4区 工程技术 Q4 INSTRUMENTS & INSTRUMENTATION Tm-Technisches Messen Pub Date : 2023-06-12 DOI:10.1515/teme-2023-0059
Alina Roß, N. Balaresque, A. Fischer
{"title":"温度和压力对风速计响应特性的影响","authors":"Alina Roß, N. Balaresque, A. Fischer","doi":"10.1515/teme-2023-0059","DOIUrl":null,"url":null,"abstract":"Abstract Cup anemometers are within the most used wind speed sensors for the wind energy industry. Wind tunnel calibrations under controlled conditions are required, but during operation uncontrolled environmental conditions occur. This is accounted for in the IEC 61400-50-1:2022 international wind measurements standard, which specifies sensor classification based on their response to external conditions, due to the influence parameters turbulence, air temperature, density, and upflow angle. Temperature and density effects are not covered appropriately in the IEC 61400-50-1:2022, since it assumes that air temperature only influences the bearing friction of a cup anemometer. No guidance is provided on evaluating variations in density, which depends on temperature and pressure. To investigate this, two cup anemometers are measured in Deutsche WindGuard’s Climatic Wind Tunnel, where density is changed by varying pressure and temperature independently. The results show that the sensor’s response to temperature can have other effects than an increase in ball bearing friction. Using pressure or temperature to modify density can even cause opposing results. Hence, varying temperatures and pressures independently is crucial to characterize a sensor’s response. The results correspond to cup anemometers, but the methodology is applicable on all sensors.","PeriodicalId":56086,"journal":{"name":"Tm-Technisches Messen","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Temperature and pressure effects on the response behavior of anemometers\",\"authors\":\"Alina Roß, N. Balaresque, A. Fischer\",\"doi\":\"10.1515/teme-2023-0059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Cup anemometers are within the most used wind speed sensors for the wind energy industry. Wind tunnel calibrations under controlled conditions are required, but during operation uncontrolled environmental conditions occur. This is accounted for in the IEC 61400-50-1:2022 international wind measurements standard, which specifies sensor classification based on their response to external conditions, due to the influence parameters turbulence, air temperature, density, and upflow angle. Temperature and density effects are not covered appropriately in the IEC 61400-50-1:2022, since it assumes that air temperature only influences the bearing friction of a cup anemometer. No guidance is provided on evaluating variations in density, which depends on temperature and pressure. To investigate this, two cup anemometers are measured in Deutsche WindGuard’s Climatic Wind Tunnel, where density is changed by varying pressure and temperature independently. The results show that the sensor’s response to temperature can have other effects than an increase in ball bearing friction. Using pressure or temperature to modify density can even cause opposing results. Hence, varying temperatures and pressures independently is crucial to characterize a sensor’s response. The results correspond to cup anemometers, but the methodology is applicable on all sensors.\",\"PeriodicalId\":56086,\"journal\":{\"name\":\"Tm-Technisches Messen\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tm-Technisches Messen\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1515/teme-2023-0059\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tm-Technisches Messen","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1515/teme-2023-0059","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

摘要杯式风速计是风能工业中最常用的风速传感器。需要在受控条件下进行风洞校准,但在运行过程中会出现不受控的环境条件。这在IEC 61400-50-1:2022国际风测量标准中得到了解释,该标准根据影响参数湍流、空气温度、密度和上升流角对外部条件的响应规定了传感器的分类。在IEC 61400-50-1:2022中没有适当地涵盖温度和密度的影响,因为它假设空气温度只影响杯式风速计的轴承摩擦。由于密度的变化取决于温度和压力,因此没有提供评价的指导。为了研究这个问题,在德国风卫士的气候风洞中测量了两个杯状风速计,其中密度分别随着压力和温度的变化而变化。结果表明,传感器对温度的响应可以产生其他影响,而不是增加滚珠轴承的摩擦。使用压力或温度来改变密度甚至会产生相反的结果。因此,独立变化的温度和压力对于表征传感器的响应至关重要。结果与杯式风速计相对应,但该方法适用于所有传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Temperature and pressure effects on the response behavior of anemometers
Abstract Cup anemometers are within the most used wind speed sensors for the wind energy industry. Wind tunnel calibrations under controlled conditions are required, but during operation uncontrolled environmental conditions occur. This is accounted for in the IEC 61400-50-1:2022 international wind measurements standard, which specifies sensor classification based on their response to external conditions, due to the influence parameters turbulence, air temperature, density, and upflow angle. Temperature and density effects are not covered appropriately in the IEC 61400-50-1:2022, since it assumes that air temperature only influences the bearing friction of a cup anemometer. No guidance is provided on evaluating variations in density, which depends on temperature and pressure. To investigate this, two cup anemometers are measured in Deutsche WindGuard’s Climatic Wind Tunnel, where density is changed by varying pressure and temperature independently. The results show that the sensor’s response to temperature can have other effects than an increase in ball bearing friction. Using pressure or temperature to modify density can even cause opposing results. Hence, varying temperatures and pressures independently is crucial to characterize a sensor’s response. The results correspond to cup anemometers, but the methodology is applicable on all sensors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Tm-Technisches Messen
Tm-Technisches Messen 工程技术-仪器仪表
CiteScore
1.70
自引率
20.00%
发文量
105
审稿时长
6-12 weeks
期刊介绍: The journal promotes dialogue between the developers of application-oriented sensors, measurement systems, and measurement methods and the manufacturers and measurement technologists who use them. Topics The manufacture and characteristics of new sensors for measurement technology in the industrial sector New measurement methods Hardware and software based processing and analysis of measurement signals to obtain measurement values The outcomes of employing new measurement systems and methods.
期刊最新文献
Miniaturisation of label free surface analytics by Whispering Gallery Modes Number of samples to use in estimating sinewave amplitude in the presence of noise Frontmatter 16th Dresden Sensor Symposium Integrating metrological principles into the Internet of Things: a digital maturity model for sensor network metrology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1