从诊断图像测量血液流速和流量的物理模型

A. Amini, T. Egglin, J. Pollak
{"title":"从诊断图像测量血液流速和流量的物理模型","authors":"A. Amini, T. Egglin, J. Pollak","doi":"10.1109/CIC.1993.378368","DOIUrl":null,"url":null,"abstract":"The authors present preliminary results and new technical developments in measurement of cross-sectional blood velocities and flow from a time-sequence of arteriograms. They apply the conservation of mass principle to flowing blood and the injected contrast medium in a vessel in order to obtain mathematical constraints on cross sectional velocities from a sequence of contrast-injected images. The previously employed optical flow constraint discussed by Mongrain et al. (Computers in Cardiology, 1991) and other authors is found to be a special case of this constraint. The proposed framework is also particularly efficient. The numerical methods compute a stream function (a single image) from a window of images in a time-sequence, and in a post-processing step, the cross-sectional velocity field is determined simply by application, of a gradient operator to the stream function.<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"21 1","pages":"783-786"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Physical models for measurement of blood velocity and flow from diagnostic images\",\"authors\":\"A. Amini, T. Egglin, J. Pollak\",\"doi\":\"10.1109/CIC.1993.378368\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors present preliminary results and new technical developments in measurement of cross-sectional blood velocities and flow from a time-sequence of arteriograms. They apply the conservation of mass principle to flowing blood and the injected contrast medium in a vessel in order to obtain mathematical constraints on cross sectional velocities from a sequence of contrast-injected images. The previously employed optical flow constraint discussed by Mongrain et al. (Computers in Cardiology, 1991) and other authors is found to be a special case of this constraint. The proposed framework is also particularly efficient. The numerical methods compute a stream function (a single image) from a window of images in a time-sequence, and in a post-processing step, the cross-sectional velocity field is determined simply by application, of a gradient operator to the stream function.<<ETX>>\",\"PeriodicalId\":20445,\"journal\":{\"name\":\"Proceedings of Computers in Cardiology Conference\",\"volume\":\"21 1\",\"pages\":\"783-786\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Computers in Cardiology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1993.378368\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378368","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

作者介绍了从动脉造影时间序列测量横断面血流速度和流量的初步结果和新技术进展。他们将质量守恒原理应用于血管中流动的血液和注入的造影剂,以便从一系列注入造影剂的图像中获得横截面速度的数学约束。Mongrain et al. (Computers in Cardiology, 1991)和其他作者讨论的先前使用的光流约束是这种约束的一个特例。拟议的框架也特别有效。数值方法从时间序列的图像窗口中计算流函数(单个图像),在后处理步骤中,截面速度场仅通过对流函数应用梯度算子来确定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Physical models for measurement of blood velocity and flow from diagnostic images
The authors present preliminary results and new technical developments in measurement of cross-sectional blood velocities and flow from a time-sequence of arteriograms. They apply the conservation of mass principle to flowing blood and the injected contrast medium in a vessel in order to obtain mathematical constraints on cross sectional velocities from a sequence of contrast-injected images. The previously employed optical flow constraint discussed by Mongrain et al. (Computers in Cardiology, 1991) and other authors is found to be a special case of this constraint. The proposed framework is also particularly efficient. The numerical methods compute a stream function (a single image) from a window of images in a time-sequence, and in a post-processing step, the cross-sectional velocity field is determined simply by application, of a gradient operator to the stream function.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A 528 channel system for the acquisition and display of defibrillation and electrocardiographic potentials Computers: the heart of screening Signal averaging enhancement by jitter deconvolution Numerical simulation of the flow in model skeletal muscle ventricles Transmembrane potential changes during stimulation in a bidomain model of the myocardium
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1