改良逆流免疫电泳法(MCCIE)鉴定和定量心包积水综合征病毒(HPSV)

S. Manzoor, Sajjad-ur-Rahman, I. Khan
{"title":"改良逆流免疫电泳法(MCCIE)鉴定和定量心包积水综合征病毒(HPSV)","authors":"S. Manzoor, Sajjad-ur-Rahman, I. Khan","doi":"10.4172/1948-5964.1000161","DOIUrl":null,"url":null,"abstract":"A rapid, simple, and accurate Modified Counter Current Immuno-electrophoresis (MCCIE) technique was developed and compared with the Reverse Passive Heamagglutination Assay (RPHA) for the titration of HPS virus. The MCCIE test had 100% correlation with the conventional RPHA and correctly titrated 116 samples which were already titrated with RPHA. Instead of horizontal electrophoresis chamber used in counter current Immuno-electrophoresis test, a modification in Counter Current Immuno-Electrophoresis (CCIE) test was made by using 1% melted agarose gel filled in 8 cm long and 3 mm narrow U-shaped glass tubing for the detection as well as quantification & titration of HPS virus. Results of Liver samples of 116 poultry birds including 16 broilers (6 livers were from clinically positive), 50 Desi and 50 commercial layers (adult) obtained through modified counter current Immuno-electrophoresis (MCCIE) were found similar to those found though CCIE and titres obtained through MCCIE were found similar to RPHA tests. The titres in MCCIE test were expressed as appearance of hazy colored precipitation band in the twelve U-shaped tubes. All of the six clinically positive liver samples gave positive results with titres ranging from 1:32 to 1:128. Of these 6 positive, 3 samples had 1:32, 2 samples had 1:64 and 1 sample had 1:128 titres. While none of desi and commercial layer was found to be positive. The results indicated that MCCIE is simple and inexpensive test as compared to CCIE & RPHA to detect and titrate HPS virus in the infected poultry liver samples. All the HPS virus isolates from HPS infected broiler livers and adenovirus group-I obtained from NARC, Islamabad and VRI, Lahore showed MCCIE & RPHA titre (1:64) with specific HPS antibodies.","PeriodicalId":15020,"journal":{"name":"Journal of Antivirals & Antiretrovirals","volume":"2 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Identification and Titration of Hydro Pericardium Syndrome Virus (HPSV) by using Modified Counter-Current Immuno-Electrophoresis (MCCIE)\",\"authors\":\"S. Manzoor, Sajjad-ur-Rahman, I. Khan\",\"doi\":\"10.4172/1948-5964.1000161\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A rapid, simple, and accurate Modified Counter Current Immuno-electrophoresis (MCCIE) technique was developed and compared with the Reverse Passive Heamagglutination Assay (RPHA) for the titration of HPS virus. The MCCIE test had 100% correlation with the conventional RPHA and correctly titrated 116 samples which were already titrated with RPHA. Instead of horizontal electrophoresis chamber used in counter current Immuno-electrophoresis test, a modification in Counter Current Immuno-Electrophoresis (CCIE) test was made by using 1% melted agarose gel filled in 8 cm long and 3 mm narrow U-shaped glass tubing for the detection as well as quantification & titration of HPS virus. Results of Liver samples of 116 poultry birds including 16 broilers (6 livers were from clinically positive), 50 Desi and 50 commercial layers (adult) obtained through modified counter current Immuno-electrophoresis (MCCIE) were found similar to those found though CCIE and titres obtained through MCCIE were found similar to RPHA tests. The titres in MCCIE test were expressed as appearance of hazy colored precipitation band in the twelve U-shaped tubes. All of the six clinically positive liver samples gave positive results with titres ranging from 1:32 to 1:128. Of these 6 positive, 3 samples had 1:32, 2 samples had 1:64 and 1 sample had 1:128 titres. While none of desi and commercial layer was found to be positive. The results indicated that MCCIE is simple and inexpensive test as compared to CCIE & RPHA to detect and titrate HPS virus in the infected poultry liver samples. All the HPS virus isolates from HPS infected broiler livers and adenovirus group-I obtained from NARC, Islamabad and VRI, Lahore showed MCCIE & RPHA titre (1:64) with specific HPS antibodies.\",\"PeriodicalId\":15020,\"journal\":{\"name\":\"Journal of Antivirals & Antiretrovirals\",\"volume\":\"2 1\",\"pages\":\"1-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Antivirals & Antiretrovirals\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4172/1948-5964.1000161\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Antivirals & Antiretrovirals","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/1948-5964.1000161","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

建立了一种快速、简便、准确的改良逆流免疫电泳(MCCIE)技术,并与反向被动血凝试验(RPHA)进行了比较。MCCIE试验与常规RPHA的相关性为100%,对已用RPHA滴定的116个样品进行了正确的滴定。代替了逆流免疫电泳检测中使用的水平电泳室,对逆流免疫电泳(CCIE)检测进行了改进,将1%的琼脂糖凝胶填充在8 cm长、3 mm窄的u形玻璃管中,用于HPS病毒的检测和定量滴定。结果对16只肉鸡(临床阳性6只)、50只德西蛋鸡和50只商品蛋鸡(成鸡)的肝脏进行了改良逆流免疫电泳(MCCIE)检测,结果与CCIE检测结果相似,效价与RPHA检测结果相似。MCCIE试验的滴度表示为在12个u形管中出现模糊的彩色沉淀带。6例临床阳性肝脏样本均呈阳性,滴度范围为1:32至1:128。6个阳性样品中,3个样品滴度为1:32,2个样品滴度为1:64,1个样品滴度为1:128。而设计层和商业层均未发现阳性。结果表明,与CCIE和RPHA相比,MCCIE是一种简单、廉价的方法,可用于检测和滴定感染家禽肝脏标本中的HPS病毒。从感染HPS的肉鸡肝脏分离的HPS病毒和从NARC, Islamabad和VRI, Lahore获得的腺病毒i组均显示出特异性HPS抗体的MCCIE和RPHA滴度(1:64)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Identification and Titration of Hydro Pericardium Syndrome Virus (HPSV) by using Modified Counter-Current Immuno-Electrophoresis (MCCIE)
A rapid, simple, and accurate Modified Counter Current Immuno-electrophoresis (MCCIE) technique was developed and compared with the Reverse Passive Heamagglutination Assay (RPHA) for the titration of HPS virus. The MCCIE test had 100% correlation with the conventional RPHA and correctly titrated 116 samples which were already titrated with RPHA. Instead of horizontal electrophoresis chamber used in counter current Immuno-electrophoresis test, a modification in Counter Current Immuno-Electrophoresis (CCIE) test was made by using 1% melted agarose gel filled in 8 cm long and 3 mm narrow U-shaped glass tubing for the detection as well as quantification & titration of HPS virus. Results of Liver samples of 116 poultry birds including 16 broilers (6 livers were from clinically positive), 50 Desi and 50 commercial layers (adult) obtained through modified counter current Immuno-electrophoresis (MCCIE) were found similar to those found though CCIE and titres obtained through MCCIE were found similar to RPHA tests. The titres in MCCIE test were expressed as appearance of hazy colored precipitation band in the twelve U-shaped tubes. All of the six clinically positive liver samples gave positive results with titres ranging from 1:32 to 1:128. Of these 6 positive, 3 samples had 1:32, 2 samples had 1:64 and 1 sample had 1:128 titres. While none of desi and commercial layer was found to be positive. The results indicated that MCCIE is simple and inexpensive test as compared to CCIE & RPHA to detect and titrate HPS virus in the infected poultry liver samples. All the HPS virus isolates from HPS infected broiler livers and adenovirus group-I obtained from NARC, Islamabad and VRI, Lahore showed MCCIE & RPHA titre (1:64) with specific HPS antibodies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
siRNA-Inhibition of TIGAR Hypersensitizes Human Papillomavirus-Transformed Cells to Apoptosis Induced by Chemotherapy Drugs that Cause Oxidative Stress Coroless, effective ingredient isolated from traditional Chinese medicine for the prevention and treatment of Covid-19 An Exploratory Study on COVID-19 and the Rights of Children Based on Keyword Network Analysis Comorbidities of COVID-19 Patients with Low Cycle Threshold (Ct) Value of Nucleocapsid (N) Gene: An Application to Cluster-Based Logistic Model. A Questionnaire-Based Survey to Assess the Timing of Intubation in COVID-19 Pneumonia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1