无线宽带网络应用的植入式天线设计

Jaehoon Choi, Uisheon Kim, Soonyong Lee, Kyeol Kwon
{"title":"无线宽带网络应用的植入式天线设计","authors":"Jaehoon Choi, Uisheon Kim, Soonyong Lee, Kyeol Kwon","doi":"10.1109/IWAT.2012.6178650","DOIUrl":null,"url":null,"abstract":"In this paper, an implantable planar inverted-F antenna (PIFA) for an artificial cardiac pacemaker is proposed. The antenna has a simple structure with a low profile and is placed on the top side of the pacemaker. The dimension of the pacemaker system, including the antenna element, is 42 mm × 43.6 mm × 11 mm. When the antenna is embedded in pig tissue, -10 dB impedance bandwidth of the antenna is 6 MHz (399 ~ 406 MHz). The proposed PIFA in tissue has a peak gain of -20.19 dBi and a radiation efficiency of 1.12 % at 403 MHz. When the proposed antenna is placed in a liquid flat phantom, its specific absorption ratio (SAR) value is 0.038 W/Kg (1 g tissue). Performances of the proposed PIFA is sufficient to operate at the MICS band (402 ~ 405 MHz).","PeriodicalId":6341,"journal":{"name":"2012 IEEE International Workshop on Antenna Technology (iWAT)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Design of an implantable antenna for WBAN applications\",\"authors\":\"Jaehoon Choi, Uisheon Kim, Soonyong Lee, Kyeol Kwon\",\"doi\":\"10.1109/IWAT.2012.6178650\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, an implantable planar inverted-F antenna (PIFA) for an artificial cardiac pacemaker is proposed. The antenna has a simple structure with a low profile and is placed on the top side of the pacemaker. The dimension of the pacemaker system, including the antenna element, is 42 mm × 43.6 mm × 11 mm. When the antenna is embedded in pig tissue, -10 dB impedance bandwidth of the antenna is 6 MHz (399 ~ 406 MHz). The proposed PIFA in tissue has a peak gain of -20.19 dBi and a radiation efficiency of 1.12 % at 403 MHz. When the proposed antenna is placed in a liquid flat phantom, its specific absorption ratio (SAR) value is 0.038 W/Kg (1 g tissue). Performances of the proposed PIFA is sufficient to operate at the MICS band (402 ~ 405 MHz).\",\"PeriodicalId\":6341,\"journal\":{\"name\":\"2012 IEEE International Workshop on Antenna Technology (iWAT)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Workshop on Antenna Technology (iWAT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IWAT.2012.6178650\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Workshop on Antenna Technology (iWAT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWAT.2012.6178650","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

提出了一种用于人工心脏起搏器的可植入平面倒f天线(PIFA)。该天线结构简单,外形较低,放置在起搏器的顶部。包括天线元件在内的起搏器系统尺寸为42mm × 43.6 mm × 11mm。当天线嵌入猪组织时,天线-10 dB阻抗带宽为6 MHz (399 ~ 406 MHz)。在403 MHz时,组织中PIFA的峰值增益为-20.19 dBi,辐射效率为1.12%。当天线放置在液体平面模体中时,其比吸收比(SAR)值为0.038 W/Kg (1g组织)。所提出的PIFA的性能足以在MICS频段(402 ~ 405 MHz)工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design of an implantable antenna for WBAN applications
In this paper, an implantable planar inverted-F antenna (PIFA) for an artificial cardiac pacemaker is proposed. The antenna has a simple structure with a low profile and is placed on the top side of the pacemaker. The dimension of the pacemaker system, including the antenna element, is 42 mm × 43.6 mm × 11 mm. When the antenna is embedded in pig tissue, -10 dB impedance bandwidth of the antenna is 6 MHz (399 ~ 406 MHz). The proposed PIFA in tissue has a peak gain of -20.19 dBi and a radiation efficiency of 1.12 % at 403 MHz. When the proposed antenna is placed in a liquid flat phantom, its specific absorption ratio (SAR) value is 0.038 W/Kg (1 g tissue). Performances of the proposed PIFA is sufficient to operate at the MICS band (402 ~ 405 MHz).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Antenna technology: Past, present and future Designs of fully on-chip antennas in (Bi)CMOS technology Study on the dual polarizations of the active cylindrical coated nano-particle antennas A feature of rice husk as an antenna absorber An UWB planar inverted-F antenna for wireless applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1