农村天然材料教室的热能性能研究

IF 1 4区 工程技术 Q4 ENERGY & FUELS Proceedings of the Institution of Civil Engineers-Energy Pub Date : 2022-02-21 DOI:10.1680/jener.21.00081
Fatima Zahra Benaddi, L. Boukhattem, B. Benhamou, P. Tabares-Velasco, F. Nouh
{"title":"农村天然材料教室的热能性能研究","authors":"Fatima Zahra Benaddi, L. Boukhattem, B. Benhamou, P. Tabares-Velasco, F. Nouh","doi":"10.1680/jener.21.00081","DOIUrl":null,"url":null,"abstract":"This work aims to highlight the indoor thermal comfort in a classroom building mostly built with locally available construction materials combined with some passive techniques in the hot semi-arid climate of Marrakech, Morocco. The thermal assessment of the so-called BATERRE building was analyzed against a Typical Building (TB) which represents the widest structure used in Moroccan rural classrooms and constructed with conventional materials. A TRNSYS based dynamic model was developed and validated using onsite monitoring measurements according to ASHRAE Guideline 14. Simulation results show that the BATERRE structure has a noticeable positive effect on indoor thermal comfort since its indoor air temperature remains stable while that of the TB classroom has higher oscillations. The hourly calculated indoor air temperature in BATERRE is greater by 3.6°C during winter and lower by 9.54°C during summer compared to the one in TB. Moreover, indoor thermal comfort analysis based on the ASHRAE Standard 55–2013 shows that BATERRE provides good indoor thermal comfort all year-round 63% of the time, while the corresponding indoor thermal comfort time part in TB is 32%. Furthermore, the annual thermal load of BATERRE is lower by 53% compared to that of TB.","PeriodicalId":48776,"journal":{"name":"Proceedings of the Institution of Civil Engineers-Energy","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2022-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Thermal energy performance study of a classroom built with natural materials in rural area\",\"authors\":\"Fatima Zahra Benaddi, L. Boukhattem, B. Benhamou, P. Tabares-Velasco, F. Nouh\",\"doi\":\"10.1680/jener.21.00081\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work aims to highlight the indoor thermal comfort in a classroom building mostly built with locally available construction materials combined with some passive techniques in the hot semi-arid climate of Marrakech, Morocco. The thermal assessment of the so-called BATERRE building was analyzed against a Typical Building (TB) which represents the widest structure used in Moroccan rural classrooms and constructed with conventional materials. A TRNSYS based dynamic model was developed and validated using onsite monitoring measurements according to ASHRAE Guideline 14. Simulation results show that the BATERRE structure has a noticeable positive effect on indoor thermal comfort since its indoor air temperature remains stable while that of the TB classroom has higher oscillations. The hourly calculated indoor air temperature in BATERRE is greater by 3.6°C during winter and lower by 9.54°C during summer compared to the one in TB. Moreover, indoor thermal comfort analysis based on the ASHRAE Standard 55–2013 shows that BATERRE provides good indoor thermal comfort all year-round 63% of the time, while the corresponding indoor thermal comfort time part in TB is 32%. Furthermore, the annual thermal load of BATERRE is lower by 53% compared to that of TB.\",\"PeriodicalId\":48776,\"journal\":{\"name\":\"Proceedings of the Institution of Civil Engineers-Energy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2022-02-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Civil Engineers-Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1680/jener.21.00081\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Civil Engineers-Energy","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1680/jener.21.00081","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 1

摘要

本项目的目的是在摩洛哥马拉喀什炎热的半干旱气候中,突出教室建筑的室内热舒适性,该建筑主要采用当地可用的建筑材料,并结合一些被动式技术。所谓的BATERRE建筑的热评估是根据典型建筑(TB)进行的,该建筑代表了摩洛哥农村教室中使用的最宽结构,并使用传统材料建造。根据ASHRAE指南14,开发并验证了基于TRNSYS的动态模型。仿真结果表明,BATERRE结构对室内热舒适有显著的正向影响,其室内空气温度保持稳定,而TB教室的室内空气温度振荡较大。与TB相比,BATERRE每小时计算的室内空气温度在冬季高3.6°C,在夏季低9.54°C。此外,基于ASHRAE标准55-2013的室内热舒适分析显示,BATERRE全年提供良好室内热舒适的时间占63%,而TB相应的室内热舒适时间占32%。此外,BATERRE的年热负荷比TB低53%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thermal energy performance study of a classroom built with natural materials in rural area
This work aims to highlight the indoor thermal comfort in a classroom building mostly built with locally available construction materials combined with some passive techniques in the hot semi-arid climate of Marrakech, Morocco. The thermal assessment of the so-called BATERRE building was analyzed against a Typical Building (TB) which represents the widest structure used in Moroccan rural classrooms and constructed with conventional materials. A TRNSYS based dynamic model was developed and validated using onsite monitoring measurements according to ASHRAE Guideline 14. Simulation results show that the BATERRE structure has a noticeable positive effect on indoor thermal comfort since its indoor air temperature remains stable while that of the TB classroom has higher oscillations. The hourly calculated indoor air temperature in BATERRE is greater by 3.6°C during winter and lower by 9.54°C during summer compared to the one in TB. Moreover, indoor thermal comfort analysis based on the ASHRAE Standard 55–2013 shows that BATERRE provides good indoor thermal comfort all year-round 63% of the time, while the corresponding indoor thermal comfort time part in TB is 32%. Furthermore, the annual thermal load of BATERRE is lower by 53% compared to that of TB.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.00
自引率
18.20%
发文量
35
期刊介绍: Energy addresses the challenges of energy engineering in the 21st century. The journal publishes groundbreaking papers on energy provision by leading figures in industry and academia and provides a unique forum for discussion on everything from underground coal gasification to the practical implications of biofuels. The journal is a key resource for engineers and researchers working to meet the challenges of energy engineering. Topics addressed include: development of sustainable energy policy, energy efficiency in buildings, infrastructure and transport systems, renewable energy sources, operation and decommissioning of projects, and energy conservation.
期刊最新文献
Municipal wastewater for energy generation: a favourable approach for developing nations Long-term heat storage opportunities of renewable energy for district heating networks ML based framework for optimal distributed generation management including EV loading Tidal range electricity generation into the 22nd century Wind energy potential assessment: a case study in Central India
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1