{"title":"研究高聚物固化过程的一种新的测试技术","authors":"Chen Daqian, Fan Jiang, H. Zhimin, Ge Zhengyan","doi":"10.1109/ICPADM.1991.172228","DOIUrl":null,"url":null,"abstract":"The authors describe multifunction test equipment for measuring and recording the dielectric spectrum, thermogram, and start-end gel-time of a high polymer specimen from liquid state to cure state. It is shown that the change of the polymer from liquid to solid during a complex cure process can be sensitively and accurately monitored by the dielectric analysis technique. A correlation of three parameters (viscosity, differential thermal analysis, and dielectric dissipation analysis) is established in order to supervise the technological measurement.<<ETX>>","PeriodicalId":6450,"journal":{"name":"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials","volume":"23 1","pages":"946-948 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A new testing technique for researching procedure in curing of high polymers\",\"authors\":\"Chen Daqian, Fan Jiang, H. Zhimin, Ge Zhengyan\",\"doi\":\"10.1109/ICPADM.1991.172228\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors describe multifunction test equipment for measuring and recording the dielectric spectrum, thermogram, and start-end gel-time of a high polymer specimen from liquid state to cure state. It is shown that the change of the polymer from liquid to solid during a complex cure process can be sensitively and accurately monitored by the dielectric analysis technique. A correlation of three parameters (viscosity, differential thermal analysis, and dielectric dissipation analysis) is established in order to supervise the technological measurement.<<ETX>>\",\"PeriodicalId\":6450,\"journal\":{\"name\":\"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials\",\"volume\":\"23 1\",\"pages\":\"946-948 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPADM.1991.172228\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPADM.1991.172228","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A new testing technique for researching procedure in curing of high polymers
The authors describe multifunction test equipment for measuring and recording the dielectric spectrum, thermogram, and start-end gel-time of a high polymer specimen from liquid state to cure state. It is shown that the change of the polymer from liquid to solid during a complex cure process can be sensitively and accurately monitored by the dielectric analysis technique. A correlation of three parameters (viscosity, differential thermal analysis, and dielectric dissipation analysis) is established in order to supervise the technological measurement.<>