{"title":"增加酒精浓度对血液成分的比较法医鉴定","authors":"C. ., Shrijoy Banerjee, Saumya Tripathi","doi":"10.5185/amp.2022.010427","DOIUrl":null,"url":null,"abstract":"BAC accurate and precise levels are important for forensic studies [1]. The sample collection and various methods adopted for determining blood alcohol concentrations is an important tool in forensic science and toxicological studies [2]. The differences in the concentrations of plasma and whole blood are discussed in this report. It has been reported earlier that whole blood has less water content as compared to plasma [3]. The reported ratio of the two is 1.0 1.1 [4]. The objective is to maintain the blood samples and analyze them against alcohol concentrations. In the vials used for collecting samples, preservatives and anticoagulants are added and then stored at different temperatures. In the in vivo techniques [5]. various difficulties are there. EDTA and Sodium fluoride are common preservatives for blood samples [6,7]. This report summarizes the role and effects of coagulant on BAC at concentrations of 30, 50, and 100 mg/dL from 2 mL ethanol, and n-propyl alcohol was taken as the internal standard. An aqueous solution of sodium tungstate (10% w/v) was used to precipitate the proteins. Plasma samples were centrifuged for 8 min at 3200 rpm at room temperature. Samples were extracted using 300 μL each of internal standard, adding 10% sodium tungstate. Extractions were centrifuged at 3500 rpm for 5 min at 35°C and vials were set for instrumentation. Material and methods","PeriodicalId":7297,"journal":{"name":"Advanced Materials Proceedings","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Forensic Characterization of Blood Components by Increased Alcoholic Concentrations\",\"authors\":\"C. ., Shrijoy Banerjee, Saumya Tripathi\",\"doi\":\"10.5185/amp.2022.010427\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BAC accurate and precise levels are important for forensic studies [1]. The sample collection and various methods adopted for determining blood alcohol concentrations is an important tool in forensic science and toxicological studies [2]. The differences in the concentrations of plasma and whole blood are discussed in this report. It has been reported earlier that whole blood has less water content as compared to plasma [3]. The reported ratio of the two is 1.0 1.1 [4]. The objective is to maintain the blood samples and analyze them against alcohol concentrations. In the vials used for collecting samples, preservatives and anticoagulants are added and then stored at different temperatures. In the in vivo techniques [5]. various difficulties are there. EDTA and Sodium fluoride are common preservatives for blood samples [6,7]. This report summarizes the role and effects of coagulant on BAC at concentrations of 30, 50, and 100 mg/dL from 2 mL ethanol, and n-propyl alcohol was taken as the internal standard. An aqueous solution of sodium tungstate (10% w/v) was used to precipitate the proteins. Plasma samples were centrifuged for 8 min at 3200 rpm at room temperature. Samples were extracted using 300 μL each of internal standard, adding 10% sodium tungstate. Extractions were centrifuged at 3500 rpm for 5 min at 35°C and vials were set for instrumentation. Material and methods\",\"PeriodicalId\":7297,\"journal\":{\"name\":\"Advanced Materials Proceedings\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Materials Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5185/amp.2022.010427\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Materials Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5185/amp.2022.010427","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

BAC准确和精确的水平对法医研究很重要[1]。采集样本和采用各种方法测定血液酒精浓度是法医学和毒理学研究的重要工具[2]。本报告讨论了血浆和全血浓度的差异。早前有报道称,与血浆相比,全血的含水量更少[3]。两者的报道比值为1.0 - 1.1[4]。目的是保存血液样本,并对其进行酒精浓度分析。在用于收集样品的小瓶中,添加了防腐剂和抗凝剂,然后在不同的温度下储存。体内技术[5]。有各种各样的困难。EDTA和氟化钠是血液样本中常见的防腐剂[6,7]。本报告总结了以2ml乙醇为原料,以正丙醇为内标,在30、50和100 mg/dL浓度下混凝剂对BAC的作用和影响。用钨酸钠水溶液(10% w/v)沉淀蛋白质。血浆样品在室温下3200rpm离心8min。样品用300 μL内标液提取,加入10%的钨酸钠。提取液在35°C下以3500 rpm离心5分钟,并设置小瓶用于仪器检测。材料与方法
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative Forensic Characterization of Blood Components by Increased Alcoholic Concentrations
BAC accurate and precise levels are important for forensic studies [1]. The sample collection and various methods adopted for determining blood alcohol concentrations is an important tool in forensic science and toxicological studies [2]. The differences in the concentrations of plasma and whole blood are discussed in this report. It has been reported earlier that whole blood has less water content as compared to plasma [3]. The reported ratio of the two is 1.0 1.1 [4]. The objective is to maintain the blood samples and analyze them against alcohol concentrations. In the vials used for collecting samples, preservatives and anticoagulants are added and then stored at different temperatures. In the in vivo techniques [5]. various difficulties are there. EDTA and Sodium fluoride are common preservatives for blood samples [6,7]. This report summarizes the role and effects of coagulant on BAC at concentrations of 30, 50, and 100 mg/dL from 2 mL ethanol, and n-propyl alcohol was taken as the internal standard. An aqueous solution of sodium tungstate (10% w/v) was used to precipitate the proteins. Plasma samples were centrifuged for 8 min at 3200 rpm at room temperature. Samples were extracted using 300 μL each of internal standard, adding 10% sodium tungstate. Extractions were centrifuged at 3500 rpm for 5 min at 35°C and vials were set for instrumentation. Material and methods
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modification of Stainless Steel with ZiNC and Niobium Oxides for Antimicrobial Effect Studying the impact of proper crew trainings and safety procedure during LNG bunkering Intrinsic defects formation and subsequent direct and indirect transitions due to ammonia in rGO – ZnO nanocomposites Current Trends in Rail Transported Industry Wash Water Treatments, Reuse, Recycling & Recovery: A Review Nutrient Expert as Decision Supporting Tool to Reduce Nitrate Toxicity in Cereal Crops
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1