{"title":"卷烟烟气的计算机GLC分析","authors":"J. Graham","doi":"10.2478/cttr-2013-0241","DOIUrl":null,"url":null,"abstract":"Abstract A two-stage GLC system has been developed to produce a separation of cigarette smoke \"semi-volatiles\" into several hundred peaks per analysis. Quantitative measurements of the separated peak areas, with correction for baseline drift and an internal standard value, are made by an off-line computer, using a digital output obtained from the GLC system on punched tape. The main features of the computer program used are described, and typical output data are shown. Results of analyses dealing with cigarette smoke composition, and the selective effect of various filters, are presented. The use of neophytadiene as reference compound for the selectivity calculations is described","PeriodicalId":35431,"journal":{"name":"Beitrage zur Tabakforschung International/ Contributions to Tobacco Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1970-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cigarette Smoke Analysis by Computer - GLC\",\"authors\":\"J. Graham\",\"doi\":\"10.2478/cttr-2013-0241\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract A two-stage GLC system has been developed to produce a separation of cigarette smoke \\\"semi-volatiles\\\" into several hundred peaks per analysis. Quantitative measurements of the separated peak areas, with correction for baseline drift and an internal standard value, are made by an off-line computer, using a digital output obtained from the GLC system on punched tape. The main features of the computer program used are described, and typical output data are shown. Results of analyses dealing with cigarette smoke composition, and the selective effect of various filters, are presented. The use of neophytadiene as reference compound for the selectivity calculations is described\",\"PeriodicalId\":35431,\"journal\":{\"name\":\"Beitrage zur Tabakforschung International/ Contributions to Tobacco Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1970-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Beitrage zur Tabakforschung International/ Contributions to Tobacco Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/cttr-2013-0241\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Agricultural and Biological Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Beitrage zur Tabakforschung International/ Contributions to Tobacco Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/cttr-2013-0241","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Agricultural and Biological Sciences","Score":null,"Total":0}
Abstract A two-stage GLC system has been developed to produce a separation of cigarette smoke "semi-volatiles" into several hundred peaks per analysis. Quantitative measurements of the separated peak areas, with correction for baseline drift and an internal standard value, are made by an off-line computer, using a digital output obtained from the GLC system on punched tape. The main features of the computer program used are described, and typical output data are shown. Results of analyses dealing with cigarette smoke composition, and the selective effect of various filters, are presented. The use of neophytadiene as reference compound for the selectivity calculations is described