{"title":"儿童心电图带宽研究综述","authors":"S. Luo, Hong Wei, P. Macfarlane","doi":"10.23919/CinC49843.2019.9005925","DOIUrl":null,"url":null,"abstract":"ECGs from neonates are known to have a higher frequency content than adult ECGs.The aim of the study was to determine the effect of using different filter bandwidths on neonatal ECGs initially sampled at a rate of 8000 samples per second (which permits the use of a signal bandwidth much higher than 150 Hz) and to consider the implications for routine ECG recording.48 ECGs were recorded from newly born term infants (0-48 hours postnatal) at Princess Royal Maternity Hospital, Glasgow on a Burdick 8500 electrocardiograph. The frequency response of the machine was carefully checked. Peak to peak QRS amplitudes of average beats of the 10 second recordings were measured in all 8 independent leads with the results obtained at the full bandwidth of the ECG machine regarded as the reference.The full bandwidth of the 8500 was verified as 0.05 – 540Hz. It was found that the recommended upper frequency cutoff of 250Hz in the current guideline does not meet the goal of amplitude errors <25 μV in >95% of the cases in this data set. The clinical significance of high frequency components in pediatric ECGs is currently unclear.","PeriodicalId":6697,"journal":{"name":"2019 Computing in Cardiology (CinC)","volume":"329 2-3 1","pages":"Page 1-Page 4"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Review of Bandwidth for Pediatric ECGs\",\"authors\":\"S. Luo, Hong Wei, P. Macfarlane\",\"doi\":\"10.23919/CinC49843.2019.9005925\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ECGs from neonates are known to have a higher frequency content than adult ECGs.The aim of the study was to determine the effect of using different filter bandwidths on neonatal ECGs initially sampled at a rate of 8000 samples per second (which permits the use of a signal bandwidth much higher than 150 Hz) and to consider the implications for routine ECG recording.48 ECGs were recorded from newly born term infants (0-48 hours postnatal) at Princess Royal Maternity Hospital, Glasgow on a Burdick 8500 electrocardiograph. The frequency response of the machine was carefully checked. Peak to peak QRS amplitudes of average beats of the 10 second recordings were measured in all 8 independent leads with the results obtained at the full bandwidth of the ECG machine regarded as the reference.The full bandwidth of the 8500 was verified as 0.05 – 540Hz. It was found that the recommended upper frequency cutoff of 250Hz in the current guideline does not meet the goal of amplitude errors <25 μV in >95% of the cases in this data set. The clinical significance of high frequency components in pediatric ECGs is currently unclear.\",\"PeriodicalId\":6697,\"journal\":{\"name\":\"2019 Computing in Cardiology (CinC)\",\"volume\":\"329 2-3 1\",\"pages\":\"Page 1-Page 4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 Computing in Cardiology (CinC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/CinC49843.2019.9005925\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Computing in Cardiology (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/CinC49843.2019.9005925","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
ECGs from neonates are known to have a higher frequency content than adult ECGs.The aim of the study was to determine the effect of using different filter bandwidths on neonatal ECGs initially sampled at a rate of 8000 samples per second (which permits the use of a signal bandwidth much higher than 150 Hz) and to consider the implications for routine ECG recording.48 ECGs were recorded from newly born term infants (0-48 hours postnatal) at Princess Royal Maternity Hospital, Glasgow on a Burdick 8500 electrocardiograph. The frequency response of the machine was carefully checked. Peak to peak QRS amplitudes of average beats of the 10 second recordings were measured in all 8 independent leads with the results obtained at the full bandwidth of the ECG machine regarded as the reference.The full bandwidth of the 8500 was verified as 0.05 – 540Hz. It was found that the recommended upper frequency cutoff of 250Hz in the current guideline does not meet the goal of amplitude errors <25 μV in >95% of the cases in this data set. The clinical significance of high frequency components in pediatric ECGs is currently unclear.