{"title":"基于死区时间的短寿命放射性核素INAA复合电子损耗校正","authors":"H. A. Das, E. Akaho","doi":"10.1081/TMA-120025811","DOIUrl":null,"url":null,"abstract":"Abstract The combined negative bias in gamma-spectrometry due to pile-up and (residual) dead time losses in case of short-lived radionuclides can be corrected for by way of dead time readings. The combined loss-factor depends on the ratio of the time-constants in amplifier and ADC, and on the average decay-constant over the total spectrum during measurement. Both parameters can be determined once and for all for a given routine application. The procedure is applicable up to total dead time fractions of at least 0.3 and thus covers routine instrumental neutron activation analysis (INAA) practice with short-lived radionuclides.","PeriodicalId":17525,"journal":{"name":"Journal of Trace and Microprobe Techniques","volume":"46 1","pages":"601 - 607"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dead Time Based Correction for the Combined Electronic Losses in INAA Based on Short-Lived Radionuclides\",\"authors\":\"H. A. Das, E. Akaho\",\"doi\":\"10.1081/TMA-120025811\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The combined negative bias in gamma-spectrometry due to pile-up and (residual) dead time losses in case of short-lived radionuclides can be corrected for by way of dead time readings. The combined loss-factor depends on the ratio of the time-constants in amplifier and ADC, and on the average decay-constant over the total spectrum during measurement. Both parameters can be determined once and for all for a given routine application. The procedure is applicable up to total dead time fractions of at least 0.3 and thus covers routine instrumental neutron activation analysis (INAA) practice with short-lived radionuclides.\",\"PeriodicalId\":17525,\"journal\":{\"name\":\"Journal of Trace and Microprobe Techniques\",\"volume\":\"46 1\",\"pages\":\"601 - 607\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-01-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Trace and Microprobe Techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1081/TMA-120025811\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Trace and Microprobe Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1081/TMA-120025811","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Dead Time Based Correction for the Combined Electronic Losses in INAA Based on Short-Lived Radionuclides
Abstract The combined negative bias in gamma-spectrometry due to pile-up and (residual) dead time losses in case of short-lived radionuclides can be corrected for by way of dead time readings. The combined loss-factor depends on the ratio of the time-constants in amplifier and ADC, and on the average decay-constant over the total spectrum during measurement. Both parameters can be determined once and for all for a given routine application. The procedure is applicable up to total dead time fractions of at least 0.3 and thus covers routine instrumental neutron activation analysis (INAA) practice with short-lived radionuclides.