{"title":"探讨相量测量单元在配电网中的应用","authors":"Y. Yeung, C. Lau","doi":"10.1109/PECon48942.2020.9314622","DOIUrl":null,"url":null,"abstract":"Phasor Measurement Units or PMU is a measurement device that produces synchronised measurement of phasor, frequency and rate of change of frequency from voltage and/or current signals based on a common time source that typically is the one provided by the Global Positioning System UTC-GPS [1]. It enables operators to monitor the network operating status in real time so as to take corresponding actions promptly and effectively while the network can be properly protected and supply can be restored automatically when fault incidents happen. PMU system can also provide the dedicated information to enhance the system protection scheme, supply reliability and asset utilisation so that the operators can operate the network smartly. This paper discusses system architecture design on the appropriate PMU technology for CLP Power’s system, acquisition, installation, operation and performance evaluation of the PMU system in CLP Power’s distribution network.","PeriodicalId":6768,"journal":{"name":"2020 IEEE International Conference on Power and Energy (PECon)","volume":"362 1","pages":"299-303"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Exploring the Application of Phasor Measurement Units in the Distribution Network\",\"authors\":\"Y. Yeung, C. Lau\",\"doi\":\"10.1109/PECon48942.2020.9314622\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Phasor Measurement Units or PMU is a measurement device that produces synchronised measurement of phasor, frequency and rate of change of frequency from voltage and/or current signals based on a common time source that typically is the one provided by the Global Positioning System UTC-GPS [1]. It enables operators to monitor the network operating status in real time so as to take corresponding actions promptly and effectively while the network can be properly protected and supply can be restored automatically when fault incidents happen. PMU system can also provide the dedicated information to enhance the system protection scheme, supply reliability and asset utilisation so that the operators can operate the network smartly. This paper discusses system architecture design on the appropriate PMU technology for CLP Power’s system, acquisition, installation, operation and performance evaluation of the PMU system in CLP Power’s distribution network.\",\"PeriodicalId\":6768,\"journal\":{\"name\":\"2020 IEEE International Conference on Power and Energy (PECon)\",\"volume\":\"362 1\",\"pages\":\"299-303\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Conference on Power and Energy (PECon)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECon48942.2020.9314622\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on Power and Energy (PECon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECon48942.2020.9314622","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

相量测量单元(Phasor Measurement Units,简称PMU)是一种测量装置,它基于一个共同的时间源(通常是全球定位系统UTC-GPS提供的时间源),从电压和/或电流信号中产生相量、频率和频率变化率的同步测量。[1]使运营商能够实时监控网络运行状态,及时有效地采取相应措施,在发生故障事故时,对网络进行适当的保护,并自动恢复供电。PMU系统还可以提供专用信息,以增强系统保护方案,供应可靠性和资产利用率,以便运营商可以智能地操作网络。本文讨论了适合中电系统的PMU技术的系统架构设计,以及中电配电网PMU系统的获取、安装、运行和性能评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Exploring the Application of Phasor Measurement Units in the Distribution Network
Phasor Measurement Units or PMU is a measurement device that produces synchronised measurement of phasor, frequency and rate of change of frequency from voltage and/or current signals based on a common time source that typically is the one provided by the Global Positioning System UTC-GPS [1]. It enables operators to monitor the network operating status in real time so as to take corresponding actions promptly and effectively while the network can be properly protected and supply can be restored automatically when fault incidents happen. PMU system can also provide the dedicated information to enhance the system protection scheme, supply reliability and asset utilisation so that the operators can operate the network smartly. This paper discusses system architecture design on the appropriate PMU technology for CLP Power’s system, acquisition, installation, operation and performance evaluation of the PMU system in CLP Power’s distribution network.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessment The Overall Health Condition of Transformer Using Health Index and Critical Index Approach: TNB Grid Case Study Buck Converter Design for Photovoltaic Emulator Application A Review of High-Frequency Transformers for Bidirectional Isolated DC-DC Converters Implementation of a Robust Hydrogen-based Grid System to Enhance Power Quality Design Modifications for Cogging Force Reduction in Linear Permanent Magnet Machines
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1