电网中功率和频率事件检测对缺失同步数据的鲁棒性

S. Konakalla, R. D. de Callafon
{"title":"电网中功率和频率事件检测对缺失同步数据的鲁棒性","authors":"S. Konakalla, R. D. de Callafon","doi":"10.1109/ICRERA.2017.8191171","DOIUrl":null,"url":null,"abstract":"Phasor Measurement Unit (PMU) data provides time synchronized measurements of important electrical and power signals in AC power grids. The sheer volume of three phase electric grid PMU data, typically measured at 60 samples second, necessitates the use of automatic event (anomaly) detection for grid monitoring and control. However, this becomes an unwieldy task in cases of PMU data dropouts due to the unobservable state of the grid. Hence, robustness to missing phasor measurements would be critical in order to monitor and control the electric grid in an orderly manner. This paper illustrates an approach for interpolation of PMU data in case of missing data points by optimal filtering of phasor data along with event detection. It is shown that optimal filters can be estimated on the basis of non linear recursive search optimization on real-time PMU data and these filters can be used to generate forecasts in case of missing PMU measurements. The approach is illustrated on phasor data obtained from a microPMU system developed by Power Standards Lab for data ride-through in case of dropouts.","PeriodicalId":6535,"journal":{"name":"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"61 1","pages":"808-812"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Robustness to missing synchrophasor data for power and frequency event detection in electric grids\",\"authors\":\"S. Konakalla, R. D. de Callafon\",\"doi\":\"10.1109/ICRERA.2017.8191171\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Phasor Measurement Unit (PMU) data provides time synchronized measurements of important electrical and power signals in AC power grids. The sheer volume of three phase electric grid PMU data, typically measured at 60 samples second, necessitates the use of automatic event (anomaly) detection for grid monitoring and control. However, this becomes an unwieldy task in cases of PMU data dropouts due to the unobservable state of the grid. Hence, robustness to missing phasor measurements would be critical in order to monitor and control the electric grid in an orderly manner. This paper illustrates an approach for interpolation of PMU data in case of missing data points by optimal filtering of phasor data along with event detection. It is shown that optimal filters can be estimated on the basis of non linear recursive search optimization on real-time PMU data and these filters can be used to generate forecasts in case of missing PMU measurements. The approach is illustrated on phasor data obtained from a microPMU system developed by Power Standards Lab for data ride-through in case of dropouts.\",\"PeriodicalId\":6535,\"journal\":{\"name\":\"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)\",\"volume\":\"61 1\",\"pages\":\"808-812\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICRERA.2017.8191171\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICRERA.2017.8191171","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

相量测量单元(PMU)数据提供交流电网中重要电气和电力信号的时间同步测量。三相电网PMU数据的绝对数量,通常以每秒60个样本的速度测量,需要使用自动事件(异常)检测来进行电网监测和控制。然而,在由于网格的不可观察状态而导致PMU数据丢失的情况下,这将成为一项棘手的任务。因此,为了以有序的方式监测和控制电网,对缺失相量测量的鲁棒性至关重要。本文阐述了一种通过相量数据的最优滤波和事件检测来实现PMU数据缺失情况下的插值方法。结果表明,基于非线性递归搜索优化,可以估计出PMU实时数据的最优滤波器,这些滤波器可用于在PMU测量缺失的情况下生成预测。该方法以功率标准实验室开发的微pmu系统的相量数据为例进行了说明,该系统用于在丢失情况下进行数据穿越。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Robustness to missing synchrophasor data for power and frequency event detection in electric grids
Phasor Measurement Unit (PMU) data provides time synchronized measurements of important electrical and power signals in AC power grids. The sheer volume of three phase electric grid PMU data, typically measured at 60 samples second, necessitates the use of automatic event (anomaly) detection for grid monitoring and control. However, this becomes an unwieldy task in cases of PMU data dropouts due to the unobservable state of the grid. Hence, robustness to missing phasor measurements would be critical in order to monitor and control the electric grid in an orderly manner. This paper illustrates an approach for interpolation of PMU data in case of missing data points by optimal filtering of phasor data along with event detection. It is shown that optimal filters can be estimated on the basis of non linear recursive search optimization on real-time PMU data and these filters can be used to generate forecasts in case of missing PMU measurements. The approach is illustrated on phasor data obtained from a microPMU system developed by Power Standards Lab for data ride-through in case of dropouts.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of AC link topologies in non-isolated DC/DC triple active bridge converter for current stress minimization Modelling and attitude control of a shrouded floating offshore wind turbine with hinged structure in extreme conditions Direct load control of air conditioners in Qatar: An empirical study Stochastic unit commitment considering Markov process of wind power forecast Primary and secondary voltage/frequency controller design for energy storage devices using consensus theory
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1