{"title":"紫外光谱法测定原料药和制剂中二甲双胍的分析方法的建立与验证","authors":"Mayur Patni, S. Rawat","doi":"10.33980/jbcc.2019.v05i01.009","DOIUrl":null,"url":null,"abstract":"A rapid, simple, selective and precise UVVisible Spectrophotometric method has been developed for the determination of metformin hydrochloride in bulk forms and tablet dosage formulations. The spectrophotometric detection was as per carried out at an absorption maximum of 232 nm using phosphate buffer of pH 6.8 as solvent. The method was validated for specificity, linearity, accuracy, precision, robustness and ruggedness. The detector response for was linear over the selected concentration range 2 to 12μg/ml with a correlation coefficient of 0.994. The accuracy was carried out as per recovery study and found between 99.1 % to 100.45%. The results demonstrated that the excipients in the tablets did not interfere with the method and can be conveniently employed for routine quality control analysis of metformin in bulk and formulation.","PeriodicalId":15083,"journal":{"name":"Journal of Biological and chemical Chronicles","volume":"148 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Analytical Method Development and Validation for Estimation of Metformin in Bulk and Pharmaceutical Dosage Form by UV Spectrometric Method\",\"authors\":\"Mayur Patni, S. Rawat\",\"doi\":\"10.33980/jbcc.2019.v05i01.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A rapid, simple, selective and precise UVVisible Spectrophotometric method has been developed for the determination of metformin hydrochloride in bulk forms and tablet dosage formulations. The spectrophotometric detection was as per carried out at an absorption maximum of 232 nm using phosphate buffer of pH 6.8 as solvent. The method was validated for specificity, linearity, accuracy, precision, robustness and ruggedness. The detector response for was linear over the selected concentration range 2 to 12μg/ml with a correlation coefficient of 0.994. The accuracy was carried out as per recovery study and found between 99.1 % to 100.45%. The results demonstrated that the excipients in the tablets did not interfere with the method and can be conveniently employed for routine quality control analysis of metformin in bulk and formulation.\",\"PeriodicalId\":15083,\"journal\":{\"name\":\"Journal of Biological and chemical Chronicles\",\"volume\":\"148 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biological and chemical Chronicles\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33980/jbcc.2019.v05i01.009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biological and chemical Chronicles","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33980/jbcc.2019.v05i01.009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analytical Method Development and Validation for Estimation of Metformin in Bulk and Pharmaceutical Dosage Form by UV Spectrometric Method
A rapid, simple, selective and precise UVVisible Spectrophotometric method has been developed for the determination of metformin hydrochloride in bulk forms and tablet dosage formulations. The spectrophotometric detection was as per carried out at an absorption maximum of 232 nm using phosphate buffer of pH 6.8 as solvent. The method was validated for specificity, linearity, accuracy, precision, robustness and ruggedness. The detector response for was linear over the selected concentration range 2 to 12μg/ml with a correlation coefficient of 0.994. The accuracy was carried out as per recovery study and found between 99.1 % to 100.45%. The results demonstrated that the excipients in the tablets did not interfere with the method and can be conveniently employed for routine quality control analysis of metformin in bulk and formulation.