{"title":"用一种简单的电压干扰估计器在线补偿永磁同步电机中变频器的非线性","authors":"Ludek Buchta, L. Pohl","doi":"10.1109/ICCSCE.2016.7893559","DOIUrl":null,"url":null,"abstract":"This paper presents an effective compensation approach to reduce voltage error which is caused by conversion of the command phase voltages to the output voltages of the inverter. As a result of non-ideal behavior of the switching elements during the switching cycle and overall design of the invertor. The disturbance voltages cause deformation of the phase currents, torque pulsation and overall affect the control algorithm of the PMSM. The disturbance observer is developed to instantaneously estimates the disturbance voltages. It is based on the model of PMSM, known machine parameters and easily measurable variables. The validity of the proposed approach is demonstrated through results of simulations and real experiments.","PeriodicalId":6540,"journal":{"name":"2016 6th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)","volume":"142 1","pages":"135-140"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Online compensation of inverter non-linearities using a simple voltage disturbance estimator in PMSM drives\",\"authors\":\"Ludek Buchta, L. Pohl\",\"doi\":\"10.1109/ICCSCE.2016.7893559\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an effective compensation approach to reduce voltage error which is caused by conversion of the command phase voltages to the output voltages of the inverter. As a result of non-ideal behavior of the switching elements during the switching cycle and overall design of the invertor. The disturbance voltages cause deformation of the phase currents, torque pulsation and overall affect the control algorithm of the PMSM. The disturbance observer is developed to instantaneously estimates the disturbance voltages. It is based on the model of PMSM, known machine parameters and easily measurable variables. The validity of the proposed approach is demonstrated through results of simulations and real experiments.\",\"PeriodicalId\":6540,\"journal\":{\"name\":\"2016 6th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)\",\"volume\":\"142 1\",\"pages\":\"135-140\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 6th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCSCE.2016.7893559\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 6th IEEE International Conference on Control System, Computing and Engineering (ICCSCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCSCE.2016.7893559","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Online compensation of inverter non-linearities using a simple voltage disturbance estimator in PMSM drives
This paper presents an effective compensation approach to reduce voltage error which is caused by conversion of the command phase voltages to the output voltages of the inverter. As a result of non-ideal behavior of the switching elements during the switching cycle and overall design of the invertor. The disturbance voltages cause deformation of the phase currents, torque pulsation and overall affect the control algorithm of the PMSM. The disturbance observer is developed to instantaneously estimates the disturbance voltages. It is based on the model of PMSM, known machine parameters and easily measurable variables. The validity of the proposed approach is demonstrated through results of simulations and real experiments.