{"title":"采用协调三环电流-电压-电流控制器实现微电网谐波电流直接补偿和无缝运行模式转换","authors":"Jinwei He, Beihua Liang","doi":"10.1109/IPEMC.2016.7512722","DOIUrl":null,"url":null,"abstract":"It is found that connecting local load to DG interfacing converter output filter could cause significant resonance in grid-connected operation mode, even when the well-understood double-loop current control with well design control parameters according to the design guidelines. To overcome this limitation, a closed-loop triple-loop control algorithm is proposed in order to realize an accurate grid current harmonic compensation. It is demonstrated that the proposed method offers the interfacing converter the capability to seamlessly transfer from grid-tied to islanding operation, even when the transfer happens at a time with maximum line current or grid voltage.","PeriodicalId":6857,"journal":{"name":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","volume":"18 1","pages":"2690-2693"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Direct microgrid harmonic current compensation and seamless operation mode transfer using coordinated triple-loop current-voltage-current controller\",\"authors\":\"Jinwei He, Beihua Liang\",\"doi\":\"10.1109/IPEMC.2016.7512722\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is found that connecting local load to DG interfacing converter output filter could cause significant resonance in grid-connected operation mode, even when the well-understood double-loop current control with well design control parameters according to the design guidelines. To overcome this limitation, a closed-loop triple-loop control algorithm is proposed in order to realize an accurate grid current harmonic compensation. It is demonstrated that the proposed method offers the interfacing converter the capability to seamlessly transfer from grid-tied to islanding operation, even when the transfer happens at a time with maximum line current or grid voltage.\",\"PeriodicalId\":6857,\"journal\":{\"name\":\"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)\",\"volume\":\"18 1\",\"pages\":\"2690-2693\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEMC.2016.7512722\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2016.7512722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Direct microgrid harmonic current compensation and seamless operation mode transfer using coordinated triple-loop current-voltage-current controller
It is found that connecting local load to DG interfacing converter output filter could cause significant resonance in grid-connected operation mode, even when the well-understood double-loop current control with well design control parameters according to the design guidelines. To overcome this limitation, a closed-loop triple-loop control algorithm is proposed in order to realize an accurate grid current harmonic compensation. It is demonstrated that the proposed method offers the interfacing converter the capability to seamlessly transfer from grid-tied to islanding operation, even when the transfer happens at a time with maximum line current or grid voltage.