光伏电池和组件在发电机组中有利位置的影响

K. Reiche, R. Preu, G. Kleiss, K. Bucher
{"title":"光伏电池和组件在发电机组中有利位置的影响","authors":"K. Reiche, R. Preu, G. Kleiss, K. Bucher","doi":"10.1109/WCPEC.1994.520173","DOIUrl":null,"url":null,"abstract":"The effect of advantageous placing when assembling solar cells or modules to PV modules or generating arrays respectively is investigated. The idea is to take advantage of thermal inhomogenities within a PV generating unit to reduce a possible mismatch between nonidentical components when operated at MPP (maximum power point). The cases of series and parallel connecting photovoltaic generating components are studied. The authors simulated the output of a cell production (or module production respectively) and estimated the effect on generator efficiency. As result, they found a possible gain in the energy output of up to 3% for the set-up of a PV array (parallel connected case) while the effect occurring within a module is negligible (series connected case). A simple rule for advantageous module placing within a PV array is formulated.","PeriodicalId":20517,"journal":{"name":"Proceedings of 1994 IEEE 1st World Conference on Photovoltaic Energy Conversion - WCPEC (A Joint Conference of PVSC, PVSEC and PSEC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1994-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Effects of advantageous placing of PV cells and modules in generating units\",\"authors\":\"K. Reiche, R. Preu, G. Kleiss, K. Bucher\",\"doi\":\"10.1109/WCPEC.1994.520173\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effect of advantageous placing when assembling solar cells or modules to PV modules or generating arrays respectively is investigated. The idea is to take advantage of thermal inhomogenities within a PV generating unit to reduce a possible mismatch between nonidentical components when operated at MPP (maximum power point). The cases of series and parallel connecting photovoltaic generating components are studied. The authors simulated the output of a cell production (or module production respectively) and estimated the effect on generator efficiency. As result, they found a possible gain in the energy output of up to 3% for the set-up of a PV array (parallel connected case) while the effect occurring within a module is negligible (series connected case). A simple rule for advantageous module placing within a PV array is formulated.\",\"PeriodicalId\":20517,\"journal\":{\"name\":\"Proceedings of 1994 IEEE 1st World Conference on Photovoltaic Energy Conversion - WCPEC (A Joint Conference of PVSC, PVSEC and PSEC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-12-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1994 IEEE 1st World Conference on Photovoltaic Energy Conversion - WCPEC (A Joint Conference of PVSC, PVSEC and PSEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WCPEC.1994.520173\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1994 IEEE 1st World Conference on Photovoltaic Energy Conversion - WCPEC (A Joint Conference of PVSC, PVSEC and PSEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WCPEC.1994.520173","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

研究了太阳能电池或组件分别装配到光伏组件或发电阵列时的有利位置的影响。这个想法是利用光伏发电机组内的热不均匀性来减少在MPP(最大功率点)运行时不相同组件之间可能的不匹配。研究了光伏发电组件串联和并联的情况。作者模拟了电池生产(或模块生产)的输出,并估计了对发电机效率的影响。结果,他们发现PV阵列(并联连接情况)设置的能量输出可能增加3%,而模块内发生的影响可以忽略不计(串联连接情况)。制定了在光伏阵列内放置有利模块的简单规则。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of advantageous placing of PV cells and modules in generating units
The effect of advantageous placing when assembling solar cells or modules to PV modules or generating arrays respectively is investigated. The idea is to take advantage of thermal inhomogenities within a PV generating unit to reduce a possible mismatch between nonidentical components when operated at MPP (maximum power point). The cases of series and parallel connecting photovoltaic generating components are studied. The authors simulated the output of a cell production (or module production respectively) and estimated the effect on generator efficiency. As result, they found a possible gain in the energy output of up to 3% for the set-up of a PV array (parallel connected case) while the effect occurring within a module is negligible (series connected case). A simple rule for advantageous module placing within a PV array is formulated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optimisation of photovoltaic water pumps coupled with an interfacing pulse width modulated DC/AC inverter power conditioning device Module orientated photovoltaic inverters-a comparison of different circuits Japanese space solar cell activities-GaAs and Si InP solar cell improvement by inverse delta-doping Improvement of AlGaAs solar cell grown on Si substrate
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1