用医用线性加速器和伽玛治疗仪治疗病人的各种方法的放射治疗成分的定义方法学

IF 0.2 Q4 INSTRUMENTS & INSTRUMENTATION Devices and Methods of Measurements Pub Date : 2020-12-17 DOI:10.21122/2220-9506-2020-11-4-289-297
E. Titovich, M. Piatkevich, N. Makarava
{"title":"用医用线性加速器和伽玛治疗仪治疗病人的各种方法的放射治疗成分的定义方法学","authors":"E. Titovich, M. Piatkevich, N. Makarava","doi":"10.21122/2220-9506-2020-11-4-289-297","DOIUrl":null,"url":null,"abstract":"One of the main factors affecting the effectiveness of radiation therapy is the constancy of the patient’s position on the treatment table created by immobilization devices of various designs and held throughout the entire irradiation procedure, which guarantees the accuracy of the delivery of the prescribed dose distribution. The purpose of the work was to establish the numerical values of the dominant components of a radiation therapy session for each of the irradiation techniques most commonly used in clinical practice of the radiation therapy.To determine the numerical values of the components of the radiation therapy session, the authors have measured each component for some clinical cases of patients’ irradiation placed. The patients had been diagnosed with the following malignant tumours: prostate cancer, breast cancer, lung cancer, head and neck tumours. More than 2000 individual measurements have been carried out with the help of such medical linear accelerators as \"Clinac\", \"Unique\", \"Truebeam\", and the gamma-therapeutic apparatus named \"Theratron\".The numerical values of the time spent on 3 groups of parameters of an irradiation session were established: the mechanical parameters of the radiation therapy equipment, the functional characteristics of the irradiation systems and the parameters that directly depend on the personnel involved in an irradiation procedure.According to the measurement results, the flow diagram for the procedures of verifying a patient’s position on the therapeutic table (2 different techniques), preceding their irradiation and the radiation therapy procedures themselves was proposed. It has been shown that a number of session components can run in parallel to each other thus optimizing the time spent by a patient in the treatment room.Using the obtained values of the time spent on the radiation session parameters it is possible to actualize the mathematical model that will allow the medical physicist to determine in advance the duration of the irradiation session at the stage of treatment planning and choose a radiation therapy technique taking into account the individual parameters of the irradiation session in each particular clinical case.","PeriodicalId":41798,"journal":{"name":"Devices and Methods of Measurements","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2020-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Methodology of Defining of the Radiation Therapy Components for Various Methods of Patients’ Treating Using Medical Linear Accelerators and Gamma-Therapeutic Devices\",\"authors\":\"E. Titovich, M. Piatkevich, N. Makarava\",\"doi\":\"10.21122/2220-9506-2020-11-4-289-297\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the main factors affecting the effectiveness of radiation therapy is the constancy of the patient’s position on the treatment table created by immobilization devices of various designs and held throughout the entire irradiation procedure, which guarantees the accuracy of the delivery of the prescribed dose distribution. The purpose of the work was to establish the numerical values of the dominant components of a radiation therapy session for each of the irradiation techniques most commonly used in clinical practice of the radiation therapy.To determine the numerical values of the components of the radiation therapy session, the authors have measured each component for some clinical cases of patients’ irradiation placed. The patients had been diagnosed with the following malignant tumours: prostate cancer, breast cancer, lung cancer, head and neck tumours. More than 2000 individual measurements have been carried out with the help of such medical linear accelerators as \\\"Clinac\\\", \\\"Unique\\\", \\\"Truebeam\\\", and the gamma-therapeutic apparatus named \\\"Theratron\\\".The numerical values of the time spent on 3 groups of parameters of an irradiation session were established: the mechanical parameters of the radiation therapy equipment, the functional characteristics of the irradiation systems and the parameters that directly depend on the personnel involved in an irradiation procedure.According to the measurement results, the flow diagram for the procedures of verifying a patient’s position on the therapeutic table (2 different techniques), preceding their irradiation and the radiation therapy procedures themselves was proposed. It has been shown that a number of session components can run in parallel to each other thus optimizing the time spent by a patient in the treatment room.Using the obtained values of the time spent on the radiation session parameters it is possible to actualize the mathematical model that will allow the medical physicist to determine in advance the duration of the irradiation session at the stage of treatment planning and choose a radiation therapy technique taking into account the individual parameters of the irradiation session in each particular clinical case.\",\"PeriodicalId\":41798,\"journal\":{\"name\":\"Devices and Methods of Measurements\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2020-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Devices and Methods of Measurements\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21122/2220-9506-2020-11-4-289-297\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Devices and Methods of Measurements","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21122/2220-9506-2020-11-4-289-297","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 1

摘要

影响放射治疗有效性的主要因素之一是患者在治疗台上的位置的稳定性,这种稳定性是由各种设计的固定装置创造的,并在整个照射过程中保持不变,这保证了规定剂量分布的准确性。这项工作的目的是为临床放射治疗实践中最常用的每种放射技术建立放射治疗过程中主要成分的数值。为了确定放射治疗过程中各组成部分的数值,作者测量了一些病人接受放射治疗的临床病例的各组成部分。这些患者被诊断患有以下恶性肿瘤:前列腺癌、乳腺癌、肺癌、头颈部肿瘤。在"Clinac"、"Unique"、"Truebeam"等医用直线加速器和名为"Theratron"的伽马治疗仪的帮助下,进行了2000多次单独测量。建立了三组辐照参数所花费时间的数值:放射治疗设备的机械参数,辐照系统的功能特征以及直接依赖于参与辐照程序的人员的参数。根据测量结果,提出了在放射治疗前验证患者在治疗台上的位置(两种不同的技术)以及放射治疗过程本身的流程图。有研究表明,一些会话组件可以彼此并行运行,从而优化患者在治疗室中花费的时间。利用所获得的花在放射阶段参数上的时间值,就有可能实现数学模型,使医学物理学家能够在治疗计划阶段提前确定放射阶段的持续时间,并在考虑到每个特定临床病例的放射阶段的个别参数的情况下选择一种放射治疗技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Methodology of Defining of the Radiation Therapy Components for Various Methods of Patients’ Treating Using Medical Linear Accelerators and Gamma-Therapeutic Devices
One of the main factors affecting the effectiveness of radiation therapy is the constancy of the patient’s position on the treatment table created by immobilization devices of various designs and held throughout the entire irradiation procedure, which guarantees the accuracy of the delivery of the prescribed dose distribution. The purpose of the work was to establish the numerical values of the dominant components of a radiation therapy session for each of the irradiation techniques most commonly used in clinical practice of the radiation therapy.To determine the numerical values of the components of the radiation therapy session, the authors have measured each component for some clinical cases of patients’ irradiation placed. The patients had been diagnosed with the following malignant tumours: prostate cancer, breast cancer, lung cancer, head and neck tumours. More than 2000 individual measurements have been carried out with the help of such medical linear accelerators as "Clinac", "Unique", "Truebeam", and the gamma-therapeutic apparatus named "Theratron".The numerical values of the time spent on 3 groups of parameters of an irradiation session were established: the mechanical parameters of the radiation therapy equipment, the functional characteristics of the irradiation systems and the parameters that directly depend on the personnel involved in an irradiation procedure.According to the measurement results, the flow diagram for the procedures of verifying a patient’s position on the therapeutic table (2 different techniques), preceding their irradiation and the radiation therapy procedures themselves was proposed. It has been shown that a number of session components can run in parallel to each other thus optimizing the time spent by a patient in the treatment room.Using the obtained values of the time spent on the radiation session parameters it is possible to actualize the mathematical model that will allow the medical physicist to determine in advance the duration of the irradiation session at the stage of treatment planning and choose a radiation therapy technique taking into account the individual parameters of the irradiation session in each particular clinical case.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Devices and Methods of Measurements
Devices and Methods of Measurements INSTRUMENTS & INSTRUMENTATION-
自引率
25.00%
发文量
18
审稿时长
8 weeks
期刊最新文献
Structure of Silicon Wafers Planar Surface before and after Rapid Thermal Treatment Assessment of Surface Roughness of Non-Metallic Materials during Laser Processing Bifacial Photovоltaic Sensor for Insolation Energy Resource Monitoring A Morphological Approach to Development of a Process for Measurement Uncertainty Estimation Energy-Dispersive X-Ray Microanalysis – as a Method for Study the Aluminium-Polysilicon Interface after Exposure with Long-Term and Rapid Thermal Annealing
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1