关于架空配电线路架空避雷器的布置

Z. M. Nawi, M. Kadir, W. Ahmad
{"title":"关于架空配电线路架空避雷器的布置","authors":"Z. M. Nawi, M. Kadir, W. Ahmad","doi":"10.1109/ICMSAO.2011.5775628","DOIUrl":null,"url":null,"abstract":"Lightning performance of distribution line is an important issue in the countries with high lightning density such as Malaysia. Many studies have been carried out to investigate the lightning performance and thus protect the overhead line from this overvoltage. This paper presents the line performance sensitivity studies of a special 33kV line underbuilt on transmission structure by mean of line arrester placement. The simulation is carried out using PSCAD/EMTDC software to determine the backflashover rate (BFR), based on the placement of line arrester. Results are then compared with the actual data provided by the TNB (Malaysian utility company) with some recommendations proposed for the improvement of the line.","PeriodicalId":6383,"journal":{"name":"2011 Fourth International Conference on Modeling, Simulation and Applied Optimization","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On the placement of line arrester on underbuilt overhead distribution line\",\"authors\":\"Z. M. Nawi, M. Kadir, W. Ahmad\",\"doi\":\"10.1109/ICMSAO.2011.5775628\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lightning performance of distribution line is an important issue in the countries with high lightning density such as Malaysia. Many studies have been carried out to investigate the lightning performance and thus protect the overhead line from this overvoltage. This paper presents the line performance sensitivity studies of a special 33kV line underbuilt on transmission structure by mean of line arrester placement. The simulation is carried out using PSCAD/EMTDC software to determine the backflashover rate (BFR), based on the placement of line arrester. Results are then compared with the actual data provided by the TNB (Malaysian utility company) with some recommendations proposed for the improvement of the line.\",\"PeriodicalId\":6383,\"journal\":{\"name\":\"2011 Fourth International Conference on Modeling, Simulation and Applied Optimization\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-04-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Fourth International Conference on Modeling, Simulation and Applied Optimization\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMSAO.2011.5775628\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Fourth International Conference on Modeling, Simulation and Applied Optimization","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMSAO.2011.5775628","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在马来西亚等雷电密度高的国家,配电线路的防雷性能是一个重要的问题。许多研究已经进行了调查雷电性能,从而保护架空线路从这个过电压。本文采用敷设线路避雷器的方法,对架空输电结构上的33kV特殊线路的线路性能灵敏度进行了研究。利用PSCAD/EMTDC软件进行仿真,以确定基于线路避雷器位置的反闪速(BFR)。然后将结果与TNB(马来西亚公用事业公司)提供的实际数据进行比较,并提出一些改进线路的建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
On the placement of line arrester on underbuilt overhead distribution line
Lightning performance of distribution line is an important issue in the countries with high lightning density such as Malaysia. Many studies have been carried out to investigate the lightning performance and thus protect the overhead line from this overvoltage. This paper presents the line performance sensitivity studies of a special 33kV line underbuilt on transmission structure by mean of line arrester placement. The simulation is carried out using PSCAD/EMTDC software to determine the backflashover rate (BFR), based on the placement of line arrester. Results are then compared with the actual data provided by the TNB (Malaysian utility company) with some recommendations proposed for the improvement of the line.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impact and Scope of Electric Power Generation Demand Using Renewable Energy Resources Due to COVID-19 Introductory Lectures on Convex Optimization - A Basic Course Development of energy harvesting device using piezoelectric material Modelling and simulation of solar chimney power plant performances in southern region of Algeria A sequential approach for fault detection and identification of vehicles' ultrasonic parking sensors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1