{"title":"环面角膜塑形镜治疗青少年中重度散光近视1年临床疗效观察","authors":"Jiaying Wang, Chenhao Yang, Li Shen","doi":"10.3760/CMA.J.ISSN.1006-4443.2017.08.013","DOIUrl":null,"url":null,"abstract":"Objective \nTo observe the clinical efficacy of Toric design orthokeratology for myopia adolescents with moderate to high astigmatism. \n \n \nMethods \nA retrospective study. Twenty-four patients (40 eyes, Spherical group), were fitted with spherical orthokeratology lenses and 11 patients (18eyes, Toric group), were fitted with Toric design orthokeratology. Comparison of two groups 1 year eye axis of two different design orthokeratology. Patients fitted with Toric design orthokeratology lenses were measured uncorrected visual acuity (UCVA), corneal astigmatism and mean corneal curvature before lens wear and after wearing the lenses for 1 week, 1 month, 6 months, and 1 year. The relationship among the orthokeratology alignment zones curvature, flat K, corneal curvature with corneal diameter 5mm, 4mm place were analyzed. Date was analyzed with paired t test, independent samples t test and one-way ANOVA. \n \n \nResults \nAfter I year, AL increased by 0.25±0.14 (mm), 0.23±0.28 (mm) in the Spherical group and Toric group, indicating a statistically significant difference compared with those lens wear (t=-10.868, P 0.05). The uncorrected visual acuity (UCVA) had a statistically significant difference compared with UCVA before lens wear (F=83.185, P 0.05). Average corneal curvature had a statistically significant difference before and after lens wear (P 0.05), while had statistically significant difference with 5mm corneal diameter curvature (P <0.05). \n \n \nConclusions \nToric design and spherical design orthokeratology have similar effects in AL control with adolescents. Toric design orthokeratology can be fitted on myopic patients with moderate-to-high corneal astigmatism, and can improve the UCVA, reduce the corneal curvature, effectively and safely. \n \n \nKey words: \nToric design Othokeratology; Corneal astigmatism; Myopia; Axial length","PeriodicalId":10236,"journal":{"name":"中国实用眼科杂志","volume":"51 1","pages":"803-807"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical efficacy observation of Toric orthokeratology in myopic adolescent with moderate to high astigmatism for 1 year\",\"authors\":\"Jiaying Wang, Chenhao Yang, Li Shen\",\"doi\":\"10.3760/CMA.J.ISSN.1006-4443.2017.08.013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective \\nTo observe the clinical efficacy of Toric design orthokeratology for myopia adolescents with moderate to high astigmatism. \\n \\n \\nMethods \\nA retrospective study. Twenty-four patients (40 eyes, Spherical group), were fitted with spherical orthokeratology lenses and 11 patients (18eyes, Toric group), were fitted with Toric design orthokeratology. Comparison of two groups 1 year eye axis of two different design orthokeratology. Patients fitted with Toric design orthokeratology lenses were measured uncorrected visual acuity (UCVA), corneal astigmatism and mean corneal curvature before lens wear and after wearing the lenses for 1 week, 1 month, 6 months, and 1 year. The relationship among the orthokeratology alignment zones curvature, flat K, corneal curvature with corneal diameter 5mm, 4mm place were analyzed. Date was analyzed with paired t test, independent samples t test and one-way ANOVA. \\n \\n \\nResults \\nAfter I year, AL increased by 0.25±0.14 (mm), 0.23±0.28 (mm) in the Spherical group and Toric group, indicating a statistically significant difference compared with those lens wear (t=-10.868, P 0.05). The uncorrected visual acuity (UCVA) had a statistically significant difference compared with UCVA before lens wear (F=83.185, P 0.05). Average corneal curvature had a statistically significant difference before and after lens wear (P 0.05), while had statistically significant difference with 5mm corneal diameter curvature (P <0.05). \\n \\n \\nConclusions \\nToric design and spherical design orthokeratology have similar effects in AL control with adolescents. Toric design orthokeratology can be fitted on myopic patients with moderate-to-high corneal astigmatism, and can improve the UCVA, reduce the corneal curvature, effectively and safely. \\n \\n \\nKey words: \\nToric design Othokeratology; Corneal astigmatism; Myopia; Axial length\",\"PeriodicalId\":10236,\"journal\":{\"name\":\"中国实用眼科杂志\",\"volume\":\"51 1\",\"pages\":\"803-807\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国实用眼科杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.1006-4443.2017.08.013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国实用眼科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1006-4443.2017.08.013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
目的观察环面形角膜塑形镜治疗青少年中度至高度散光近视的临床疗效。方法回顾性研究。24例患者(40眼,球形组)配戴球形角膜塑形镜,11例患者(18眼,Toric组)配戴Toric设计角膜塑形镜。两组1年眼轴两种不同设计角膜塑形术的比较。配戴Toric设计角膜塑形镜的患者在配戴前、配戴1周、1个月、6个月和1年后分别测量非矫正视力(UCVA)、角膜散光和平均角膜曲率。分析角膜塑形对准区曲率、平面K、角膜曲率与角膜直径5mm、4mm位置的关系。数据分析采用配对t检验、独立样本t检验和单因素方差分析。结果1年后,球面组和托力组AL分别升高0.25±0.14 (mm)、0.23±0.28 (mm),与晶状体磨损组比较差异有统计学意义(t=-10.868, P < 0.05)。未矫正视力(UCVA)与配戴前比较,差异有统计学意义(F=83.185, p0.05)。晶状体佩戴前后平均角膜曲率差异有统计学意义(P <0.05),角膜直径5mm曲率差异有统计学意义(P <0.05)。结论环形角膜塑形术与球形角膜塑形术对青少年AL的控制效果相似。环形设计角膜塑形镜可用于角膜中高散光的近视患者,并能有效、安全地改善UCVA,降低角膜曲率。关键词:环形设计;眼角膜学;角膜散光;近视;轴向长度
Clinical efficacy observation of Toric orthokeratology in myopic adolescent with moderate to high astigmatism for 1 year
Objective
To observe the clinical efficacy of Toric design orthokeratology for myopia adolescents with moderate to high astigmatism.
Methods
A retrospective study. Twenty-four patients (40 eyes, Spherical group), were fitted with spherical orthokeratology lenses and 11 patients (18eyes, Toric group), were fitted with Toric design orthokeratology. Comparison of two groups 1 year eye axis of two different design orthokeratology. Patients fitted with Toric design orthokeratology lenses were measured uncorrected visual acuity (UCVA), corneal astigmatism and mean corneal curvature before lens wear and after wearing the lenses for 1 week, 1 month, 6 months, and 1 year. The relationship among the orthokeratology alignment zones curvature, flat K, corneal curvature with corneal diameter 5mm, 4mm place were analyzed. Date was analyzed with paired t test, independent samples t test and one-way ANOVA.
Results
After I year, AL increased by 0.25±0.14 (mm), 0.23±0.28 (mm) in the Spherical group and Toric group, indicating a statistically significant difference compared with those lens wear (t=-10.868, P 0.05). The uncorrected visual acuity (UCVA) had a statistically significant difference compared with UCVA before lens wear (F=83.185, P 0.05). Average corneal curvature had a statistically significant difference before and after lens wear (P 0.05), while had statistically significant difference with 5mm corneal diameter curvature (P <0.05).
Conclusions
Toric design and spherical design orthokeratology have similar effects in AL control with adolescents. Toric design orthokeratology can be fitted on myopic patients with moderate-to-high corneal astigmatism, and can improve the UCVA, reduce the corneal curvature, effectively and safely.
Key words:
Toric design Othokeratology; Corneal astigmatism; Myopia; Axial length