{"title":"温度对U形和线圈形POF传感器折射率变化的影响","authors":"T. Tabaru","doi":"10.1080/01468030.2021.1904059","DOIUrl":null,"url":null,"abstract":"ABSTRACT The effect of the temperature on refractive index (RI) sensors based on U and Coil-shaped plastic optical fiber (POF) was investigated. For this purpose, four POF-RI sensor probes were produced, and RI changes caused by ethanol changes in solutions were detected. Two of the produced probes were U-shaped, while the other two were Coil-shaped. For the first time in the literature, the effect of both the geometry of the U and Coil-shaped POF-RI sensors on the sensor parameters and the effect of the medium temperature have been analyzed together. As a result of the experiments conducted at 25°C, the best RI change detection sensitivity, linearity, and resolution values were determined as 821%/RIU, 0.9974 (R2), 5.18 × 10−4. In addition, temperature dependence loss (TDL) and temperature dependence RI deviation (TDR) were measured at different temperatures (25–40°C) in the 1.3346–1.45 RI range, and the effect of temperature change on POF-RI sensor probes was characterized.","PeriodicalId":50449,"journal":{"name":"Fiber and Integrated Optics","volume":"28 1","pages":"48 - 69"},"PeriodicalIF":2.3000,"publicationDate":"2021-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"The Temperature Effect on U and Coil Shaped POF Sensors to Detect Refractive Index Change\",\"authors\":\"T. Tabaru\",\"doi\":\"10.1080/01468030.2021.1904059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT The effect of the temperature on refractive index (RI) sensors based on U and Coil-shaped plastic optical fiber (POF) was investigated. For this purpose, four POF-RI sensor probes were produced, and RI changes caused by ethanol changes in solutions were detected. Two of the produced probes were U-shaped, while the other two were Coil-shaped. For the first time in the literature, the effect of both the geometry of the U and Coil-shaped POF-RI sensors on the sensor parameters and the effect of the medium temperature have been analyzed together. As a result of the experiments conducted at 25°C, the best RI change detection sensitivity, linearity, and resolution values were determined as 821%/RIU, 0.9974 (R2), 5.18 × 10−4. In addition, temperature dependence loss (TDL) and temperature dependence RI deviation (TDR) were measured at different temperatures (25–40°C) in the 1.3346–1.45 RI range, and the effect of temperature change on POF-RI sensor probes was characterized.\",\"PeriodicalId\":50449,\"journal\":{\"name\":\"Fiber and Integrated Optics\",\"volume\":\"28 1\",\"pages\":\"48 - 69\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2021-01-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fiber and Integrated Optics\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1080/01468030.2021.1904059\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fiber and Integrated Optics","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1080/01468030.2021.1904059","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPTICS","Score":null,"Total":0}
The Temperature Effect on U and Coil Shaped POF Sensors to Detect Refractive Index Change
ABSTRACT The effect of the temperature on refractive index (RI) sensors based on U and Coil-shaped plastic optical fiber (POF) was investigated. For this purpose, four POF-RI sensor probes were produced, and RI changes caused by ethanol changes in solutions were detected. Two of the produced probes were U-shaped, while the other two were Coil-shaped. For the first time in the literature, the effect of both the geometry of the U and Coil-shaped POF-RI sensors on the sensor parameters and the effect of the medium temperature have been analyzed together. As a result of the experiments conducted at 25°C, the best RI change detection sensitivity, linearity, and resolution values were determined as 821%/RIU, 0.9974 (R2), 5.18 × 10−4. In addition, temperature dependence loss (TDL) and temperature dependence RI deviation (TDR) were measured at different temperatures (25–40°C) in the 1.3346–1.45 RI range, and the effect of temperature change on POF-RI sensor probes was characterized.
期刊介绍:
Fiber and Integrated Optics , now incorporating the International Journal of Optoelectronics, is an international bimonthly journal that disseminates significant developments and in-depth surveys in the fields of fiber and integrated optics. The journal is unique in bridging the major disciplines relevant to optical fibers and electro-optical devices. This results in a balanced presentation of basic research, systems applications, and economics. For more than a decade, Fiber and Integrated Optics has been a valuable forum for scientists, engineers, manufacturers, and the business community to exchange and discuss techno-economic advances in the field.