苏打水的稀释和加入对人工唾液中含铜桶饮料正畸丝耐腐蚀性能的影响

Amala Suvakeen, K. Kavipriya, Senthil Vadivelan, Anu Ratthika, T. Vidhya, Sindhuja Jerleen, Nilavan Anitha, R. Srinivasan, S. Rajendran, T. Gowrani
{"title":"苏打水的稀释和加入对人工唾液中含铜桶饮料正畸丝耐腐蚀性能的影响","authors":"Amala Suvakeen, K. Kavipriya, Senthil Vadivelan, Anu Ratthika, T. Vidhya, Sindhuja Jerleen, Nilavan Anitha, R. Srinivasan, S. Rajendran, T. Gowrani","doi":"10.5937/zasmat2302119a","DOIUrl":null,"url":null,"abstract":"Copper barrel brandy can be taken orally with dilution of bisleri water or soda water and without dilution. People clipped with orthodontic wires may take copper barrel brandy orally, with dilution of without dilution. How far the orthodontic wires will be affected by these items? To find an answer the present research work is undertaken. Corrosion resistance of orthodontic wires made of Ni-Ti alloy and Ni-Cr alloy in artificial saliva in the absence and presence of copper barrel, water and soda water has been evaluated by AC impedance spectra. It is generally observed that Ni-Ti alloy is more corrosion resistant than Ni-Cr alloy in artificial saliva in the presence of copper barrel, water and soda water. When orthodontic wire made of Ni-Ti is immersed in artificial saliva, the charge transfer resistance (Rt) value is 31945Ohmcm2 . When it is immersed in copper barrel + artificial saliva (AS) system, Rtvalue increase to 80000Ohmcm2 . When it is immersed in soda water + artificial saliva (AS) system, Rtvalue increase to 76450Ohmcm2 . When it is immersed in water + artificial saliva (AS) system, Rtvalue increase to 82620Ohmcm2 . On the other hand, when orthodontic wire made of Ni-Cr is immersed in artificial saliva, the charge transfer resistance (Rt) value is 80930Ohmcm2 . When it is immersed in copper barrel + artificial saliva (AS) system, Rtvalue decrease to 11104Ohmcm2 . When it is immersed in soda water + artificial saliva (AS) system, Rtvalue decrease to 10437Ohmcm2 . It implies that the people who have been clipped with orthodontic wire made of Ni-Ti alloy can take copper barrel in any form, namely, with dilution or without dilution. The people who have been clipped with orthodontic wire made of Ni-Cr alloy should avoid taking copper barrel in any form, namely, with dilution or without dilution.","PeriodicalId":23842,"journal":{"name":"Zastita materijala","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of dilution and addition of soda water on the corrosion resistance of orthodontic wires immersed in artificial saliva in presence of Copper Barrel, a hard drink\",\"authors\":\"Amala Suvakeen, K. Kavipriya, Senthil Vadivelan, Anu Ratthika, T. Vidhya, Sindhuja Jerleen, Nilavan Anitha, R. Srinivasan, S. Rajendran, T. Gowrani\",\"doi\":\"10.5937/zasmat2302119a\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Copper barrel brandy can be taken orally with dilution of bisleri water or soda water and without dilution. People clipped with orthodontic wires may take copper barrel brandy orally, with dilution of without dilution. How far the orthodontic wires will be affected by these items? To find an answer the present research work is undertaken. Corrosion resistance of orthodontic wires made of Ni-Ti alloy and Ni-Cr alloy in artificial saliva in the absence and presence of copper barrel, water and soda water has been evaluated by AC impedance spectra. It is generally observed that Ni-Ti alloy is more corrosion resistant than Ni-Cr alloy in artificial saliva in the presence of copper barrel, water and soda water. When orthodontic wire made of Ni-Ti is immersed in artificial saliva, the charge transfer resistance (Rt) value is 31945Ohmcm2 . When it is immersed in copper barrel + artificial saliva (AS) system, Rtvalue increase to 80000Ohmcm2 . When it is immersed in soda water + artificial saliva (AS) system, Rtvalue increase to 76450Ohmcm2 . When it is immersed in water + artificial saliva (AS) system, Rtvalue increase to 82620Ohmcm2 . On the other hand, when orthodontic wire made of Ni-Cr is immersed in artificial saliva, the charge transfer resistance (Rt) value is 80930Ohmcm2 . When it is immersed in copper barrel + artificial saliva (AS) system, Rtvalue decrease to 11104Ohmcm2 . When it is immersed in soda water + artificial saliva (AS) system, Rtvalue decrease to 10437Ohmcm2 . It implies that the people who have been clipped with orthodontic wire made of Ni-Ti alloy can take copper barrel in any form, namely, with dilution or without dilution. The people who have been clipped with orthodontic wire made of Ni-Cr alloy should avoid taking copper barrel in any form, namely, with dilution or without dilution.\",\"PeriodicalId\":23842,\"journal\":{\"name\":\"Zastita materijala\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zastita materijala\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5937/zasmat2302119a\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zastita materijala","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/zasmat2302119a","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

铜桶白兰地可以用比斯利水或苏打水稀释后口服,不需要稀释。夹有正畸金属丝的人可口服铜桶白兰地,稀释不稀释。这些物品对正畸金属丝的影响有多大?为了找到答案,目前的研究工作正在进行。用交流阻抗谱法测定了镍钛合金和镍铬合金正畸丝在人工唾液中铜桶、水和苏打水不存在和不存在的情况下的耐腐蚀性能。一般观察到,在铜桶、水和苏打水存在的情况下,人工唾液中Ni-Ti合金比Ni-Cr合金更耐腐蚀。当Ni-Ti制成的正畸丝浸入人工唾液中时,电荷传递电阻(Rt)值为31945Ohmcm2。当浸入铜桶+人工唾液(AS)系统时,Rtvalue增加到80000Ohmcm2。当浸入苏打水+人工唾液(AS)系统时,Rtvalue增加到76450Ohmcm2。当浸入水+人工唾液(AS)系统时,Rtvalue增加到82620Ohmcm2。另一方面,当Ni-Cr正畸丝浸入人工唾液中时,电荷传递电阻(Rt)值为80930Ohmcm2。当浸入铜桶+人工唾液(AS)系统时,Rtvalue降至11104Ohmcm2。当浸入苏打水+人工唾液(AS)系统时,Rtvalue降至10437Ohmcm2。这意味着被镍钛合金正畸丝夹住的人可以以任何形式服用铜桶,即稀释或不稀释。使用镍铬合金正畸丝夹过的人,应避免以任何形式,即稀释或未稀释的方式服用铜桶。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of dilution and addition of soda water on the corrosion resistance of orthodontic wires immersed in artificial saliva in presence of Copper Barrel, a hard drink
Copper barrel brandy can be taken orally with dilution of bisleri water or soda water and without dilution. People clipped with orthodontic wires may take copper barrel brandy orally, with dilution of without dilution. How far the orthodontic wires will be affected by these items? To find an answer the present research work is undertaken. Corrosion resistance of orthodontic wires made of Ni-Ti alloy and Ni-Cr alloy in artificial saliva in the absence and presence of copper barrel, water and soda water has been evaluated by AC impedance spectra. It is generally observed that Ni-Ti alloy is more corrosion resistant than Ni-Cr alloy in artificial saliva in the presence of copper barrel, water and soda water. When orthodontic wire made of Ni-Ti is immersed in artificial saliva, the charge transfer resistance (Rt) value is 31945Ohmcm2 . When it is immersed in copper barrel + artificial saliva (AS) system, Rtvalue increase to 80000Ohmcm2 . When it is immersed in soda water + artificial saliva (AS) system, Rtvalue increase to 76450Ohmcm2 . When it is immersed in water + artificial saliva (AS) system, Rtvalue increase to 82620Ohmcm2 . On the other hand, when orthodontic wire made of Ni-Cr is immersed in artificial saliva, the charge transfer resistance (Rt) value is 80930Ohmcm2 . When it is immersed in copper barrel + artificial saliva (AS) system, Rtvalue decrease to 11104Ohmcm2 . When it is immersed in soda water + artificial saliva (AS) system, Rtvalue decrease to 10437Ohmcm2 . It implies that the people who have been clipped with orthodontic wire made of Ni-Ti alloy can take copper barrel in any form, namely, with dilution or without dilution. The people who have been clipped with orthodontic wire made of Ni-Cr alloy should avoid taking copper barrel in any form, namely, with dilution or without dilution.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Zastita materijala
Zastita materijala Materials Science-General Materials Science
CiteScore
0.80
自引率
0.00%
发文量
26
期刊最新文献
Influence of sodium chloride on corrosion resistance of ever silver vessels in the presence of curd rice Protection from ballistic threats: an exploration of textile materials for bullet-resistant outerwear Recent advances in research from plastic materials to microplastics The electrochemical performance of perovskite LaMnO3 Effect of corrosion inhibitors on internal corrosion in oil pipelines: a brief review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1